REG NASA-LLIS-0274--1993 Lessons Learned Mars Observer Payload Data System (PDS) Exposure to Low Temperature.pdf
《REG NASA-LLIS-0274--1993 Lessons Learned Mars Observer Payload Data System (PDS) Exposure to Low Temperature.pdf》由会员分享,可在线阅读,更多相关《REG NASA-LLIS-0274--1993 Lessons Learned Mars Observer Payload Data System (PDS) Exposure to Low Temperature.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Lessons Learned Entry: 0274Lesson Info:a71 Lesson Number: 0274a71 Lesson Date: 1993-07-09a71 Submitting Organization: JPLa71 Submitted by: J. W. HarrellSubject: Mars Observer Payload Data System (PDS) Exposure to Low Temperature Abstract: During thermal vacuum testing of the flight Mars Observer PDS
2、, the subsystem was exposed to a temperature of about -47 degrees Celsius, well below the desired limit of -20 degrees C. The problem was caused by a failure in a temperature controller and was compounded by a chamber operator evaluation error.The recommendations involve use of alarm and “fail safe”
3、 circuits, pretest functional verification of the test facility, procedures required before manual override of “fail safe” devices, and continuous quality assurance monitoring of tests. Description of Driving Event: During testing of the flight Mars Observer PDS (Serial No. 1) in a thermal vacuum ch
4、amber, the subsystem was exposed to a temperature of about -47 degrees Celsius, well below the desired limit of -20 degrees C. The problem was caused by a failure in a temperature controller and was compounded by a chamber operator evaluation error. The failure of the controller during the planned d
5、escent to -20 C was detected by an alarm circuit and a “fail safe“ circuit, both of which functioned properly by closing off the supply of cold gas to the PDS baseplate heat exchanger. The chamber operator overrode the protection circuits, choosing to believe the recently calibrated temperature cont
6、roller rather than the alarms. The subsystem engineer observed from a separate data source that the hardware was exceeding the specified temperature and requested a test termination.Following analysis, evaluation and test facility corrective actions, the test of the PDS was continued and successfull
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- REGNASALLIS02741993LESSONSLEARNEDMARSOBSERVERPAYLOADDATASYSTEMPDSEXPOSURETOLOWTEMPERATUREPDF

链接地址:http://www.mydoc123.com/p-1017922.html