NFPA 400-2016 Hazardous Materials Code (Effective Date 06 15 2015 ALERT THIS STANDARD HAS BEEN MODIFIED BY A TIA OR ERRATA).pdf
《NFPA 400-2016 Hazardous Materials Code (Effective Date 06 15 2015 ALERT THIS STANDARD HAS BEEN MODIFIED BY A TIA OR ERRATA).pdf》由会员分享,可在线阅读,更多相关《NFPA 400-2016 Hazardous Materials Code (Effective Date 06 15 2015 ALERT THIS STANDARD HAS BEEN MODIFIED BY A TIA OR ERRATA).pdf(240页珍藏版)》请在麦多课文档分享上搜索。
1、NFPA400See ALERTHazardous Materials Code2016ISBN: 978-145591175-2 (Print) ISBN: 978-145591212-4 (PDF)IMPORTANT NOTICES AND DISCLAIMERS CONCERNING NFPASTANDARDS NOTICE AND DISCLAIMER OF LIABILITY CONCERNING THE USE OF NFPA STANDARDSNFPAcodes, standards, recommended practices, and guides (“NFPA Standa
2、rds”), of which the document contained herein is one, are developed through a consensus standards development process approved by the American National Standards Institute. This process brings together volunteers representing varied viewpoints and interests to achieve consensus on fire and other saf
3、ety issues. While the NFPA administers the process and establishes rules to promote fairness in the development of consensus, it does not independently test, evaluate, or verify the accuracy of any information or the soundness of any judgments contained in NFPA Standards.The NFPA disclaims liability
4、 for any personal injury, property or other damages of any nature whatsoever, whether special, indirect, consequential or compensatory, directly or indirectly resulting from the publication, use of, or reliance on NFPA Standards. The NFPA also makes no guaranty or warranty as to the accuracy or comp
5、leteness of any information published herein.In issuing and making NFPA Standards available, the NFPA is not undertaking to render professional or other services for or on behalf of any person or entity. Nor is the NFPA undertaking to perform any duty owed by any person or entity to someone else. An
6、yone using this document should rely on his or her own independent judgment or, as appropriate, seek the advice of a competent professional in determining the exercise of reasonable care in any given circumstances.The NFPA has no power, nor does it undertake, to police or enforce compliance with the
7、 contents of NFPA Standards. Nor does the NFPA list, certify, test, or inspect products, designs, or installations for compliance with this document. Any certification or other statement of compliance with the requirements of this document shall not be attributable to the NFPA and is solely the resp
8、onsibility of the certifier or maker of the statement.ALERT: THIS STANDARD HAS BEEN MODIFIED BY A TIA OR ERRATAUsers of NFPA codes, standards, recommended practices, and guides (“NFPA Standards”) should be aware that NFPA Standards may be amended from time to time through the issuance of Tentative I
9、nterim Amendments or corrected by Errata. An official NFPA Standard at any point in time consists of the current edition of the document together with any Tentative Interim Amendment and any Errata then in effect.In order to determine whether an NFPA Standard has been amended through the issuance of
10、 Tentative Interim Amendments or corrected by Errata, visit the “Codes email: stds_adminnfpa.orgFor more information about NFPA, visit the NFPA website at www.nfpa.org. All NFPA codes and standards can be viewed at no cost at www.nfpa.org/freeaccess.Copyright 2015 National Fire Protection Associatio
11、n. All Rights Reserved.NFPA400Hazardous Materials Code2016 EditionThis edition of NFPA 400, Hazardous Materials Code, was prepared by the Technical Com-mittee on Hazardous Chemicals. It was issued by the Standards Council on May 26, 2015, withan effective date of June 15, 2015, and supersedes all pr
12、evious editions.This document has been amended by one or more Tentative Interim Amendments (TIAs)and/or Errata. See “Codes (2) Class IIILiquid any liquid that has a flash point at or above 140F(60C); (a) Class IIIA Liquid any liquid that has a flashpoint at or above 140F (60C), but below 200F (93C);
13、 and(b) Class IIIB Liquid any liquid that has a flash point at orabove 200F (93C). 30, 20153.3.18* Compressed Gas System. An assembly of equipmentdesigned to contain, distribute, or transport compressedgases. 318, 20153.3.19 Container. A containment device including, but not lim-ited to, cylinders,
14、tanks, intermediate bulk containers, pressurevessels, drums, carboys, cans, bottles, boxes, bags, bins, and por-table tanks that vary in shape, size, and material of constructionand are used for holding, storing, and transporting hazardousmaterials covered by this code.3.3.19.1* Container Flammable
15、and Combustible Liquid.Any vessel of 119 gal (450 L) or less capacity used for trans-porting or storing liquids. 30, 20153.3.19.2 Closed Container Flammable and Combustible Liq-uid. A container as herein defined, so sealed by means ofa lid or other device that neither liquid nor vapor will es-cape f
16、rom it at ordinary temperatures. 30, 20153.3.19.3 ASME Container. A container constructed in ac-cordance with the ASME Boiler and Pressure Vessel Code.3.3.19.4 Combustible Containers. Containers that includepaper bags, fiber drums, plastic containers, and wooden orfiber boxes or barrels, as well as
17、noncombustible containershaving removable combustible liners or packing, and non-combustible containers having combustible overpacks.3.3.19.5 Noncombustible Containers. Containers con-structed of glass or metal that can be coated with a poly-meric material no more than132 in. (2 mils) in thickness.3
18、.3.19.6* Nonmetallic Container Solid, Flammable and Com-bustible Liquid. A container as defined in 3.3.19 con-structed of glass, plastic, fiber, or a material other thanmetal. 30, 20153.3.19.7 Overpack Container. A closed container intended toencapsulate and contain a leaking or damaged liquid or so
19、lidmaterial container thereby preventing the release of liquids,solids, or vapors and is made of the same material or similarlyprotective material as the leaking or damaged container.40011DEFINITIONS2016 Edition3.3.19.8 Cylinder Containment Vessel Gas. See 3.3.25.3.3.19.9 Storage Tank Flammable and
20、Combustible Liquid.Any vessel having a liquid capacity that exceeds 60 gal (230 L), isintended for fixed installation, and is not used for processing.30, 20153.3.19.9.1* Stationary Tank Gas. A packaging designedprimarily for stationary installations not intended for load-ing, unloading, or attachmen
21、t to a transport vehicle as partof its normal operation in the process of use. 55, 20163.3.19.10 Aboveground Tank Flammable and CombustibleLiquid. A storage tank that is installed above grade, atgrade, or below grade without backfill. 30, 20153.3.19.10.1* Atmospheric Tank Flammable and CombustibleLi
22、quid. A storage tank that has been designed to operateat pressures from atmospheric through a gauge pressure of1.0 psi (6.9 kPa) (i.e., 760 mm Hg through 812 mm Hg)measured at the top of the tank. 30, 20153.3.19.10.2 Secondary Containment Tank Flammable andCombustible Liquid. A tank that has an inne
23、r and outerwall with an interstitial space (annulus) between the wallsand which has a means of monitoring the interstitial spacefor a leak. 30, 20153.3.19.11* Portable Tank Flammable and Combustible Liq-uid. Any vessel having a liquid capacity over 60 gals(230 L) intended for storing liquids and not
24、 intended forfixed installation. 30, 20153.3.19.11.1* Portable Tank Gas. Any packaging over 60U.S. gal (227.1 L) capacity designed primarily to be loadedinto or on, or temporarily attached to, a transport vehicleor ship and equipped with skids, mountings, or accessoriesto facilitate handling of the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NFPA4002016HAZARDOUSMATERIALSCODEEFFECTIVEDATE06152015ALERTTHISSTANDARDHASBEENMODIFIEDBYATIAORERRATAPDF

链接地址:http://www.mydoc123.com/p-1008618.html