NAVY UFGS-09 22 00-2010 SUPPORTS FOR PLASTER AND GYPSUM BOARD《石膏和石膏板的支架》.pdf
《NAVY UFGS-09 22 00-2010 SUPPORTS FOR PLASTER AND GYPSUM BOARD《石膏和石膏板的支架》.pdf》由会员分享,可在线阅读,更多相关《NAVY UFGS-09 22 00-2010 SUPPORTS FOR PLASTER AND GYPSUM BOARD《石膏和石膏板的支架》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、*USACE / NAVFAC / AFCESA / NASA UFGS-09 22 00 (February 2010)-Preparing Activity: NAVFAC SupersedingUFGS-09 22 00 (August 2009)UNIFIED FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2010*SECTION TABLE OF CONTENTSDIVISION 09 - FINISHESSECTION 09 22 00SUPPORTS FOR PLA
2、STER AND GYPSUM BOARD02/10PART 1 GENERAL1.1 REFERENCES1.2 SUBMITTALS1.3 DELIVERY, STORAGE, AND HANDLINGPART 2 PRODUCTS2.1 MATERIALS2.1.1 Materials for Attachment of Lath2.1.1.1 Suspended and Furred Ceiling Systems and Wall Furring2.1.1.2 Non-loadbearing Wall Framing2.1.2 Materials for Attachment of
3、Gypsum Wallboard2.1.2.1 Suspended and Furred Ceiling Systems2.1.2.2 Nonload-Bearing Wall Framing and Furring2.1.2.3 Furring Structural Steel Columns2.1.2.4 Z-Furring Channels with Wall InsulationPART 3 EXECUTION3.1 INSTALLATION3.1.1 Systems for Attachment of Lath3.1.1.1 Suspended and Furred Ceiling
4、Systems and Wall Furring3.1.1.2 Non-loadbearing Wall Framing3.1.2 Systems for Attachment of Gypsum Wallboard3.1.2.1 Suspended and Furred Ceiling Systems3.1.2.2 Non-loadbearing Wall Framing and Furring3.1.2.3 Furring Structural Steel Columns3.1.2.4 Z-Furring Channels with Wall Insulation3.2 ERECTION
5、TOLERANCES- End of Section Table of Contents -SECTION 09 22 00 Page 1Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-*USACE / NAVFAC / AFCESA / NASA UFGS-09 22 00 (February 2010)-Preparing Activity: NAVFAC SupersedingUFGS-09 22 00 (August 2009)UNIFIE
6、D FACILITIES GUIDE SPECIFICATIONSReferences are in agreement with UMRL dated April 2010*SECTION 09 22 00SUPPORTS FOR PLASTER AND GYPSUM BOARD02/10*NOTE: This guide specification covers the requirements for non-loadbearing cold-formed metal framing, furring, and ceiling suspension systems for the att
7、achment of lath, plaster, stucco, and wallboard.Edit this guide specification for project specific requirements by adding, deleting, or revising text. For bracketed items, choose applicable items(s) or insert appropriate information.Remove information and requirements not required in respective proj
8、ect, whether or not brackets are present.Comments and suggestions on this guide specification are welcome and should be directed to the technical proponent of the specification. A listing of Technical Proponents, including their organization designation and telephone number, is on the Internet.Recom
9、mended changes to a UFGS should be submitted as a Criteria Change Request (CCR).*NOTE: Load-bearing cold-formed steel framing is included in Section 05 40 00 COLD-FORMED METAL FRAMING. Metal suspension systems for acoustical ceilings are included in Section 09 51 00 ACOUSTICAL CEILINGS.*NOTE: On the
10、 drawings, show:1. Locations of each type of metal framing, furring, or suspension system.2. Spacing and gage of members if other than those SECTION 09 22 00 Page 2Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-required by referenced publication.3.
11、Seismic restraint for projects located in seismic zone 2, 3, or 4, in accordance with ANSI/AISC 341 and UFC 3-310-04, “Seismic Design for Buildings“.*PART 1 GENERAL1.1 REFERENCES*NOTE: This paragraph is used to list the publications cited in the text of the guide specification. The publications are
12、referred to in the text by basic designation only and listed in this paragraph by organization, designation, date, and title.Use the Reference Wizards Check Reference feature when you add a RID outside of the Sections Reference Article to automatically place the reference in the Reference Article. A
13、lso use the Reference Wizards Check Reference feature to update the issue dates.References not used in the text will automatically be deleted from this section of the project specification when you choose to reconcile references in the publish print process.*The publications listed below form a part
14、 of this specification to the extent referenced. The publications are referred to within the text by the basic designation only.AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC)ANSI/AISC 341 (2005; Suppl No. 1 2005) Seismic Provisions for Structural Steel BuildingsASTM INTERNATIONAL (ASTM)ASTM A 463/A
15、 463M (2009a) Standard Specification for Steel Sheet, Aluminum-CoatedASTM A 653/A 653M (2009a) Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip ProcessASTM C 645 (2009a) Nonstructural Steel Framing MembersASTM C 754 (2009a) Inst
16、allation of Steel Framing Members to Receive Screw-Attached Gypsum Panel ProductsASTM C 841 (2003; R 2008e1) Installation of Interior SECTION 09 22 00 Page 3Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-Lathing and FurringASTM C 847 (2009) Standard
17、 Specification for Metal LathNATIONAL ASSOCIATION OF ARCHITECTURAL METAL MANUFACTURERS (NAAMM)NAAMM ML/SFA 920 (1991) Metal Lathing and FurringUNDERWRITERS LABORATORIES (UL)UL Fire Resistance (2009) Fire Resistance Directory1.2 SUBMITTALS*NOTE: Review submittal description (SD) definitions in Sectio
18、n 01 33 00 SUBMITTAL PROCEDURES and edit the following list to reflect only the submittals required for the project. Submittals should be kept to the minimum required for adequate quality control.A “G” following a submittal item indicates that the submittal requires Government approval. Some submitt
19、als are already marked with a “G”. Only delete an existing “G” if the submittal item is not complex and can be reviewed through the Contractors Quality Control system. Only add a “G” if the submittal is sufficiently important or complex in context of the project.For submittals requiring Government a
20、pproval on Army projects, a code of up to three characters within the submittal tags may be used following the “G“ designation to indicate the approving authority. Codes for Army projects using the Resident Management System (RMS) are: “AE“ for Architect-Engineer; “DO“ for District Office (Engineeri
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYUFGS0922002010SUPPORTSFORPLASTERANDGYPSUMBOARD 石膏 石膏板 支架 PDF

链接地址:http://www.mydoc123.com/p-984754.html