NAVY MIL-STD-2042-5 B-2002 FIBER OPTIC CABLE TOPOLOGY INSTALLATION STANDARD METHODS FOR NAVAL SHIPS (CONNECTORS AND INTERCONNECTIONS) (PART 5 OF 7 PARTS)《海军舰光缆拓扑装置标准方法(插件和联络线)》.pdf
《NAVY MIL-STD-2042-5 B-2002 FIBER OPTIC CABLE TOPOLOGY INSTALLATION STANDARD METHODS FOR NAVAL SHIPS (CONNECTORS AND INTERCONNECTIONS) (PART 5 OF 7 PARTS)《海军舰光缆拓扑装置标准方法(插件和联络线)》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-STD-2042-5 B-2002 FIBER OPTIC CABLE TOPOLOGY INSTALLATION STANDARD METHODS FOR NAVAL SHIPS (CONNECTORS AND INTERCONNECTIONS) (PART 5 OF 7 PARTS)《海军舰光缆拓扑装置标准方法(插件和联络线)》.pdf(119页珍藏版)》请在麦多课文档分享上搜索。
1、METRICMIL-STD-2042-5B(SH)25 July 2002SUPERSEDINGMIL-STD-2042-5A(SH)29 September 1997MIL-STD-2042-5(SH)7 July 1993DEPARTMENT OF DEFENSESTANDARD PRACTICEFIBER OPTIC CABLE TOPOLOGY INSTALLATIONSTANDARD METHODS FORNAVAL SHIPS(CONNECTORS AND INTERCONNECTIONS)(PART 5 OF 7 PARTS)AMSC N/A AREA GDRQDISTRIBUT
2、ION STATEMENT A. Approved for public release; distribution is unlimited.Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-STD-2042-5B(SH)iiFOREWORD1. This Department of Defense Standard Practice is approved for use by theNaval Sea Systems Command,
3、Department of the Navy, and is available for use by allDepartments and Agencies of the Department of Defense.2. Beneficial comments (recommendations, additions, deletions) and anypertinent data which may be of use in improving this document should be addressed toDepartment of the Navy, Naval Sea Sys
4、tems Command, ATTN: SEA 05Q, 1333 Isaac HullAvenue Southeast, Stop 5160, Washington Navy Yard, DC 20376-5160 by using the self-addressed Standardization Document Improvement Proposal (DD Form 1426) appearing atthe end of this document or by letter.3. This standard practice provides detailed informat
5、ion and guidance topersonnel concerned with the installation of fiber optic cable topologies (opticalfiber cabling and associated components) on Naval surface ships and submarines. Themethods specified herein are not identifiable to any specific ship class or type,but are intended to standardize and
6、 minimize variations in installation methods toenhance the compatibility of the installations on all Naval ships.4. In order to provide flexibility in the use and update of the installationmethods, this standard practice is issued in eight parts; the basic standardpractice and seven numbered parts a
7、s follows:Part 1 CablesPart 2 EquipmentPart 3 Cable PenetrationsPart 4 CablewaysPart 5 Connectors and InterconnectionsPart 6 TestsPart 7 Pierside Connectivity Cable Assemblies and Interconnection HardwareProvided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-
8、,-MIL-STD-2042-5B(SH)iiiCONTENTSPARAGRAPH PAGE1. SCOPE . 11.1 Scope . 11.1.1 Applicability . 12. APPLICABLE DOCUMENTS 22.1 General . 22.2 Government documents 22.2.1 Specifications, standards and handbooks . 22.2.2 Other government documents 32.3 Non-government publications . 32.4 Order of precedenc
9、e . 33. DEFINITIONS . 43.1 General fiber optics terms 43.2 Acronyms 43.3 Authorized approval. 43.4 BOF bundle 43.5 BOF fiber . 43.6 BOF tube 43.7 End user equipment 43.8 Fiber optic cable plant . 43.9 Fiber optic cable topology 43.10 Fiber optic interconnection box . 43.11 Installing activity . 43.1
10、2 Local cable . 43.13 Minimum bend diameter . 53.14 Optical fiber cable . 53.15 Optical fiber cable component (OFCC). . 53.16 Outlet box. . 53.17 Trunk . 53.18 Trunk cable . 53.19 Tube furcation unit . 54. GENERAL REQUIREMENTS 64.1 Optical fiber cable interconnection . 64.1.1 Interconnection compone
11、nt selection . 64.2 Fiber connectors 64.2.1 Installation 64.3 Fiber optic splices . 74.3.1 Installation 74.4 Tests . 74.5 Safety precautions 75. DETAILED REQUIREMENTS . 95.1 Heavy-duty connector installation . 95.1.1 Heavy-duty connectors with removable backshells . 95.1.2 Heavy-duty connectors with
12、 integral backshells 95.1.3 Heavy-duty connectors with insert retention nuts 95.1.4 Heavy-duty connectors with light duty strain relief . 95.2 Light duty connector installation . 95.3 Mechanical (rotary) splice installation . 95.4 COTS light duty connector installation .Provided by IHSNot for Resale
13、No reproduction or networking permitted without license from IHS-,-,-MIL-STD-2042-5B(SH)ivCONTENTSPARAGRAPH PAGE6. NOTES 106.1 Intended use . 106.2 Issue of DODISS 106.3 Standard method designation 106.4 Subject term (key word) listing 10METHOD5A1 Multiple terminus connector installation 5A1-15B1 Si
14、ngle terminus connector installation 5B1-15C1 Mechanical splice ferrule installation 5C1-1TABLE PAGE5A1-I Equipment and materials . 5A1-15A1-II Cable stripping dimensions 5A1-65A1-III Equipment and materials 5A1-225A1-IV Cable stripping dimensions . 5A1-425A1-V Equipment and materials 5A1-605B1-I Eq
15、uipment and materials . 5B1-15C1-I Equipment and materials . 5C1-1FIGURE5A1-1 Backshell parts on the cable (straight backshell). 5A1-45A1-2 Cable stripping dimensions. . 5A1-55A1-3 Mixing the epoxy. . 5A1-75A1-4 Injecting epoxy into the terminus. 5A1-85A1-5 Inserting the fiber into the terminus. . 5
16、A1-95A1-6 Inserting a terminus in a cure adapter. 5A1-105A1-7 Termini in the curing oven. 5A1-105A1-8 Scoring the fiber. . 5A1-115A1-9 Placing the terminus in the insertion tool. 5A1-125A1-10 Inserting the terminus in the polishing tool. . 5A1-125A1-11 Removing the terminus from the polishing tool.
17、. 5A1-135A1-12 Scoring the fiber. . 5A1-145A1-13 Placing the terminus in the insertion tool. 5A1-155A1-14 Inserting the terminus in the polishing tool. . 5A1-155A1-15 Removing the terminus from the polishing tool. . 5A1-175A1-16 Removing the terminus from the polishing tool. . 5A1-185A1-17 Quality c
18、heck. . 5A1-185A1-18 Installing the terminus in the insert. . 5A1-195A1-19 Installing the alignment sleeve. . 5A1-205A1-20 Removing the terminus from the insert. . 5A1-215A1-21 Strain relief parts on the cable. 5A1-265A1-22 Installing the O-ring. . 5A1-275A1-23 Tightening the kevlar compression nut.
19、 . 5A1-285A1-24 Strain relief parts on the cable. 5A1-295A1-25 Installing the O-ring. . 5A1-315A1-26 Strain relief parts on the cable. 5A1-335A1-27 Installing the O-ring. . 5A1-345A1-28 Tightening the kevlar compression nut. . 5A1-355A1-29 Strain relief parts on the cable. 5A1-375A1-30 Installing th
20、e O-ring. . 5A1-385A1-31 Tightening the kevlar compression nut. . 5A1-40Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-STD-2042-5A(SH)vCONTENTSFIGURE PAGE5A1-32 Cable stripping dimensions. 5A1-415A1-33 Mixing the epoxy. 5A1-445A1-34 Injecting ep
21、oxy into the terminus. . 5A1-445A1-35 Inserting the fiber into the terminus. 5A1-455A1-36 Inserting a terminus in a cure adapter. 5A1-465A1-37 Termini in the curing oven. 5A1-475A1-38 Scoring the fiber. . 5A1-485A1-39 Placing the terminus in the insertion tool. 5A1-485A1-40 Inserting the terminus in
22、 the polishing tool. . 5A1-495A1-41 Removing the terminus from the polishing tool. . 5A1-505A1-42 Scoring the fiber. . 5A1-515A1-43 Placing the terminus in the insertion tool. 5A1-515A1-44 Inserting the terminus in the polishing tool. . 5A1-525A1-45 Removing the terminus from the polishing tool. . 5
23、A1-535A1-46 Removing the terminus from the polishing tool. . 5A1-545A1-47 Quality check. . 5A1-555A1-48 Installing the spacing shafts. . 5A1-555A1-49 Installing the terminus in the insert. . 5A1-565A1-50 Installing the alignment sleeve. . 5A1-575A1-51 Removing the terminus from the insert. . 5A1-585
24、A1-52 Assembling the backshell. 5A1-585A1-53 Mixing the epoxy. 5A1-635A1-54 Injecting epoxy into the terminus. . 5A1-645A1-55 Inserting the fiber into the terminus. 5A1-655A1-56 Inserting a terminus in a cure adapter. 5A1-665A1-57 Termini in the curing oven. 5A1-665A1-58 Scoring the fiber. . 5A1-675
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILSTD20425B2002FIBEROPTICCABLETOPOLOGYINSTALLATIONSTANDARDMETHODSFORNAVALSHIPSCONNECTORSANDINTERCONNECTIONSPART5OF7PARTS

链接地址:http://www.mydoc123.com/p-982377.html