NAVY MIL-E-24403 A (1)-1983 ELECTRODES-WELDING FLUX CORED GENERAL SPECIFICATION FOR《流量中心电极焊接法总说明书》.pdf
《NAVY MIL-E-24403 A (1)-1983 ELECTRODES-WELDING FLUX CORED GENERAL SPECIFICATION FOR《流量中心电极焊接法总说明书》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-E-24403 A (1)-1983 ELECTRODES-WELDING FLUX CORED GENERAL SPECIFICATION FOR《流量中心电极焊接法总说明书》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、MIL-E-24403A (I) 34 m 9999906 O246864 T m Form 3a 3b MIL-E-24403A(SH) AMENDMENT 1 30 August 1983 Diameter sizes (inches) . 0.045, 0.052 0.045, 0.052, 0.0625, 5/64, 3/32 MILITARY SPECIFICATION 3“: 4 ELECTRODES - WELDING, FLUX CORED, GENERAL SPECIFICATION FOR 0.045, 0.052, 0,0625, 0.068, 0.072, 5/64,
2、3/32, 7/64, 0.120, 1/8, 5/32 11 This amendment forms a part: of MIL-E-24403A(SH), dated 21 December 1981, and is approved for use by the Naval Sea Systems Command, Department of the Navy, and is available for use by all Departments and Agencies of the Department of Defense. PAGE 1 TABLE I. Delete an
3、d Substitute: “TABLE I. Electrode diameter sizes. At bottom of page “Beneficial comments“ statement, line 3: Delete “SEA 3112“ and substitute “SEA 5523“. PAGE 4 3.4.4: Add: “The chemical composition of the core ingredients necessary to produce a weld that meets all requirements is optional with the
4、manufacturer.“ 3.4.6: Delete and substitute: 3.4.6 Soundness. Unless otherwise specified in the detail specification (see 3.2), groove welds shall meet the requirements of NAVSEA 0900-LP-003-9000, class 1 for radiographic inspection.“ I1 :- U.S. GOVERNMENT PRINTING OFFICE: 1383-605-034:4554 1 of 10
5、FSC 3439 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-E-24403A(SH) AMENDMENT 1 PAGE 10 4.6.2.1 and 4.6.2.1.1: Delete and substitute: “4.6.2.1 Radiographic inspection. Radiographic inspection shall be in accordance with level 2-2T of MIL-STD-27
6、1.” PAGE 11 4.6.5: Delete and substitute: “4.6.5 Diffusible hydrogen. A sample of each lot for each size and MIL type of electrodes furnished to the requirements of this specification shall be tested for diffusible hydrogen level in the weld metal. the deposited weld metal shall be determined by the
7、 analytical method of gas chromatography (see 4.6.5.2) or by the method of collection over mercury (see 4.6.5.3). correlation with the two methods above may be used. The hydrogen level of Alternate methods or apparatus which yield results of one to one “4.6.5.1 Specimen preparation. The test specime
8、ns for the diffusible hydrogen analysis shall be prepared according to the following: (a) The testing of each size and MIL type electrode requires four separate diffusible hydrogen determinations, that is, four test specimens. Each test specimen consists of a 10- by 15- by 30- millimeter (mm) steel
9、block with the weld metal deposited upon it. For collection over mercury method, specimefis shall be 1/2 by 1 by 5-inch (see 4.6.5.3). These larger specimens shall be weighed to the nearest 0.1 gram before and after welding. steel block. For electrodes 1/16 inch and smaller, the test specimen weldin
10、g direction is the 30-mm direction and a single test specimen between run-on and run-off pieces is used for each weld deposit. For electrodes larger than 1/16 inch, the test specimen welding direction is the 15-mm direction and two test specimens between run-on and run-off pieces are used for each w
11、eld deposit. The arrangements of test specimens with run-on and run-off pieces for the various electrode sizes are shown on figure 3. The material for the test specimen and run-on and run-off pieces shall be plain hot rolled ordinary strength steel containing not more than 0.25 percent carbon, 0.35
12、percent silicon, 0.03 percent phosphorous and 0.03 percent sulfur. Rimmed steel is not acceptable. 1 hour at 1200-1235F prior to finish grinding to size. finished surfaces shall be orthogonal with dimension tolerances of plus or minus 0.25 mm and maximum surface roughness of 120 microinches root mea
13、n square (rms) on all surfaces. For the collection over mercury method, the edges and corners shall be rounded (approximately 1/64-inch radius) to break the sharp edge to prevent scratching the eudimeter tube. (b) The test specimen thickness is always the 10-mm direction of the (c) The material shal
14、l be degassed by holding for The 2 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-E-24403A (1) 34 7777706 0246866 3 M MIL-E-24403A(SH) AMENDMENT 1 Each test specimen shall be given an identification number or mark by stamping or engraving its su
15、rface opposite to the welding surface. number shall be removed by lightly sanding on 600 grit paper prior to degreasing and weighing. Each test specimen shall be weighed to the nearest 0.01 gram before welding and the weight shall be recorded along with the specimen identification. Immediately prior
16、 to welding the test specimen and run-on and run-off pieces shall be thoroughly degreased. Three feet of electrode shall be fed out of the gun, cut off and discarded just prior to each test weld deposit. The welding parameters during test welding shall be the same as those used to make the test weld
17、ments as shown on figure 1. The pieces of the test assembly (see figure 3), shall be placed in the appropriate copper clamp (see figure 4), butted together and tightly clamped. An annealed copper foil (as shown on figure 4 fixture for 1/16-inch and smaller electrodes) is used between the test assemb
18、ly and copper clamp. This protects the clamp from arc strikes and thermally couples the test assembly with the copper clamp. The foil may be annealed and cleaned after each use. The foil is 1 to 2 mm in thickness. Immediately prior to welding, the temperature of the test assembly and copper clamp sh
19、all be 20 2 5 degrees Celsius (OC). The copper clamp may be water cooled. A single stringer bead (without weaving) shall be deposited in the flat position, approximately 100 mm in length. The test assembly shall be removed from the fixture, quenched in iced water within 5 seconds of extinguishing th
20、e arc, and agitated vigorously in the iced water until cold to the touch (about 20 seconds). It shall then be immediately removed from the quench and placed in a low temperature liquid bath at dry ice temperature (-78OC) or colder. At dry ice temperature the test assembly may be stored for a maximum
21、 of 3 days before loading into the hydrogen sampler cannister. At liquid nitrogen temperature (-196OC) the test assembly may be stored for a maximum of 3 weeks. cold, break off run-on and run-off pieces. Remove any remaining slag. If an electrode larger than 1/16 inch was used, break the test assemb
22、ly into two test specimens again. During the breaking and cleaning operation, the test pieces shall not remain out of the low temperature bath for more than 60 seconds at a time. If necessary, they shall be returned to the bath for a mnimum of 120 seconds each time between portions of the cleaning a
23、nd breaking operation. Each cleaned 10- by 15- by 30-mm block with its weld deposit constitutes a test specimen. After completion of the cleaning and breaking operation, each test specimen shall be returned to the low temperature bath for a minimum of 120 seconds. Any upset from the identification m
24、ark or Remove test assembly from low temperature bath and, while still “4.6.5.2 Gas chromatography method. The gas chromatography method, when used, shall be conducted in accordance with the procedures as specified in 4.6.5.2 :2. 3 Provided by IHSNot for ResaleNo reproduction or networking permitted
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILE24403A11983ELECTRODESWELDINGFLUXCOREDGENERALSPECIFICATIONFOR 流量 中心 电极 焊接 说明书 PDF

链接地址:http://www.mydoc123.com/p-979022.html