NAVY MIL-C-85257-1981 CORD ASSEMBLY DETONATING《爆炸电线电缆组装》.pdf
《NAVY MIL-C-85257-1981 CORD ASSEMBLY DETONATING《爆炸电线电缆组装》.pdf》由会员分享,可在线阅读,更多相关《NAVY MIL-C-85257-1981 CORD ASSEMBLY DETONATING《爆炸电线电缆组装》.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、I - 1 MIL-C-85257 33 9999906 0364386 L I - - -c- - MIL-C-85257(AS) 53 June 1981 - , MILITARY SPECIFICATION CORD ASSEMBLY, DETONATING . - . This specification is approved for use by the Naval Air Systems Command, Department of the Wavy, and is available for use by all Departments and Agencies of the
2、Department of Defense. 1. SCOPE. 1.1 Scope. This specification establishes the requirements for manufacture and acceptance of the detonating cord assembly criti- cal item, hereinafter referred to as the assembly. 2, APPLICABLE DOCMENTS . 2.1 Issues of documents. The following documents of the issues
3、 in effect on date of invitation for bids or request for proposal, form a part of this specification to the extent speoified herein. SPECIFICATIONS FEDERAL QQ-A-225/6 Aluminum Alloy Bar, Rod, and Wire, Rolled, Drawn, or Cold Finished, 2024. _-_ . - _u- -. .-. . . - - Beneficial comments (recommendat
4、ions, additions, -deletions) and 1 ,any pertinent data which may be of use in improving this document I !should be addressed to: Commanding Officer, Naval Air Engineering I kenter, Engineering Specifications and Standards Department I(ESSD), Code 93, Lakehurst, NJ 08733, by using the self-addressed
5、Standardization Document Improvement Proposal (DD Form 1426) .appearing at the end of this document, or by I_ letter. - . I Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-C.-85257 13 m 777770b 03611387 3 MILITARY MIL-B-85251 STANDARDS FEDERAL FE
6、D-STD-102 MILITARY MIL-STD-105 MIL-STD-109 MIL-STD-129 MIL- STD- 33 1 MIL-STD-453 Iil I L - STD - 8 1 O MIL-STD-1168 MIL-STD-45662 Bomb, Binary Chemical, BLU-8O/B. Preservation, Packaging and Packing Levels. Sampling Procedures and Tables for Inspection by Attributes. Quality Assurance Terms and Def
7、initions. Marking for Shipment and Storage. Fuze and Fuze Components, Environ- mental and Performance Tests for. Radiographic Inspection. Environmental Test Methods. Ammunition Lot Numbering. Calibration System Requirements. DRAWINGS Naval Air Systems Command (Code Ident 30003) X49 006 7 6 Cord Asse
8、mbly, Detonating. (Copies of specifications, standards, drawings, and publications required by contractors in connection with specified procurement functions should be obtained from the procuring activity or as directed by the contracting officer.) 2 Provided by IHSNot for ResaleNo reproduction or n
9、etworking permitted without license from IHS-,-,-MIL-C-5257 13 = 7999906 0364388 5 c 2.2 Other publications. The following documents form a part of this specification to the extent specified herein. cated, the issue in effect on date of invitation for bids or request for proposal shall apply. Unless
10、 otherwise indi- DEPARTMENT OF TRANSPORTATION Code of Federal Regulations 49 CFR 171-178 Transportation. (Application for copies should be addressed to the Superintendent of Documents, Government Printing Office, Washington, D.C. 20402.) American Society for Testing and Materials ASTM-E498-73 ASTM-E
11、499-73 ASTM-F78-71 (Applications for copies shou for Testing and Materials, 1916 3. REQUIREMENTS. Standard Methods of Testing for Leaks Using the Mass Spectrometer Leak Detector or Residual Gas Analyzer in the Tracer Probe Mode. Standard Methods of Testing for Leaks Using the Mass Spectrometer Leak
12、Detector in the Detector Probe Mode. Standard Method for Calibration of Helium Leak Detectors by use of Secondary Standards. d be addressed to the American Society Race Street, Philadelphia, PA 19103.) 3.1 Item description. The assembly consists of four mild detonating cords affixed into an aluminum
13、 sleeve with a common initiating charge and cover. cover. The opposite end of each cord has an output charge and 3 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-MIL-C-85Z57 13 7779706 0364387 7 i NIL-c-85 2 5 7 ( AS 3.2 Characteristics. 3.2.1 Perf
14、ormance. 3.2.1.1 Initiation and output. When the assembly is initiated with a MARK 339 MOD 1 Fuze or an approved equivalent energy source, all four boosters shall detonate and the output of each booster shall be sufficient to produce a minimum dent 0.013 inch deep in a steel witness plate (see Figur
15、e i). 3.2.1.2 Temperature shock. “he assembly shall withstand alternating exposure to temperatures of -48 degrees Celsius (OC) for 90 minutes, +75OC for 30 minutes, and +254OC for 10 minutes without degradation of performance, when tested at +155OC, and shall not constitute a safety hazard after exp
16、osure to temperature shock. 3.2.1.3 Low temperature. The assembly shall withstand exposure to a temperature of -62C for 14 days without degradation of perf ormance. 3.2.1.4 HirJh temperature (storage). The assembly shall withstand exposure to a temperature of +74OC for 14 days without degradation of
17、 performance. 3.2.1.5 High temperature (safetv). The assembly shall withstand exposure to a temperature of +99OC for 2 hours followed by +280OC for 30 minutes without constituting a safety hazard and shall not detonate, deflagrate, or burn. 3.3 Design and construction. 3.3.1 Production drawings. The
18、 assembly shall be fabricated and assembled in accordance with the drawings, parts lists, and other documents listed on Drawing X4900676 and as specified herein. 3.3.1.2 Mechanical integritv. Each assembly shall be free from voids, inclusions, or impurities in any of the explosive compo- nents and t
19、he internal construction of the assembly shall conform to Drawing X4900676. 3.3.1.3 Leak rate, Each assembly shall have a leak rate of less than 1x105 atmospheric cubic centimeters of helium per second at a differential pressure of 1 atmosphere and a temperature of +25 - +5oc. 4 Provided by IHSNot f
20、or ResaleNo reproduction or networking permitted without license from IHS-,-,- - - MIL-C-85257 33 m 7777706 0364370 3 U.2J MIL- C- 85 2 5 7 ( AS 1 I 1 ,.-. _- ./- t KY- -*- ,/- I l .r. 1 I I i i 1 I 1 2.0 i 0.; I MATERIAL: AISI 1018 OR 1020 COLD ROLLED FARDNESS: ROCKWELL B70-590 FIGURE 1. Witness pl
21、ate. iN. 5 Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,- - VIL-C-85257 13 M 777770b 0364173 5 M MIL-C-85257 (AS) 3.3.2 Standards of manufacture. 3.3.2.1 Certification. When specified in the contract or purchase order (see 6.2.2), the contractor sh
22、all include written certification, accompanied by objective quality evidence as defined in MIL-STD-109, that the materials, processes, and parts used in the assembly meet the applicable requirements for each item. F 3.3.2.2 Working environnient. Any special working environments for the manufacture o
23、f the assemblies shall be as specified in MIL-B-85251. 3.3.2.3 Manufacturing processes aiid procedures. When specified in the contract or purchase order (see 6.2.2), the contractor shall pre- pare, in the contractors own format, written procedures covering the detailed equipment and process requirem
24、ents and procedures which the contractor proposes to use and does use in the manufacture of assemblies to this specification. Copies of such work instructions, together with referenced documents, shall be made available to the procuring activity in the manner specified in the contract or purchase or
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NAVYMILC852571981CORDASSEMBLYDETONATING 爆炸 电线电缆 组装 PDF

链接地址:http://www.mydoc123.com/p-978172.html