NACE TM0193-2000 Laboratory Corrosion Testing of Metals in Static Chemical Cleaning Solutions at Temperatures Below 93 Degrees C (200 Degrees F)《在温度低于93℃(200F)下静态化学清洗剂的实验室腐蚀测试 项目编号.pdf
《NACE TM0193-2000 Laboratory Corrosion Testing of Metals in Static Chemical Cleaning Solutions at Temperatures Below 93 Degrees C (200 Degrees F)《在温度低于93℃(200F)下静态化学清洗剂的实验室腐蚀测试 项目编号.pdf》由会员分享,可在线阅读,更多相关《NACE TM0193-2000 Laboratory Corrosion Testing of Metals in Static Chemical Cleaning Solutions at Temperatures Below 93 Degrees C (200 Degrees F)《在温度低于93℃(200F)下静态化学清洗剂的实验室腐蚀测试 项目编号.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、StandardTest MethodLaboratory Corrosion Testing of Metals in StaticChemical Cleaning Solutions at TemperaturesBelow 93C (200F)This NACE International standard represents a consensus of those individual members who havereviewed this document, its scope, and provisions. Its acceptance does not in any
2、respectpreclude anyone, whether he has adopted the standard or not, from manufacturing, marketing,purchasing, or using products, processes, or procedures not in conformance with this standard.Nothing contained in this NACE International standard is to be construed as granting any right, byimplicatio
3、n or otherwise, to manufacture, sell, or use in connection with any method, apparatus,or product covered by Letters Patent, or as indemnifying or protecting anyone against liability forinfringement of Letters Patent. This standard represents minimum requirements and should in noway be interpreted as
4、 a restriction on the use of better procedures or materials. Neither is thisstandard intended to apply in all cases relating to the subject. Unpredictable circumstances maynegate the usefulness of this standard in specific instances. NACE International assumes noresponsibility for the interpretation
5、 or use of this standard by other parties and acceptsresponsibility for only those official NACE International interpretations issued by NACEInternational in accordance with its governing procedures and policies which preclude theissuance of interpretations by individual volunteers.Users of this NAC
6、E International standard are responsible for reviewing appropriate health,safety, environmental, and regulatory documents and for determining their applicability in relationto this standard prior to its use. This NACE International standard may not necessarily addressall potential health and safety
7、problems or environmental hazards associated with the use ofmaterials, equipment, and/or operations detailed or referred to within this standard. Users of thisNACE International standard are also responsible for establishing appropriate health, safety, andenvironmental protection practices, in consu
8、ltation with appropriate regulatory authorities ifnecessary, to achieve compliance with any existing applicable regulatory requirements prior to theuse of this standard.CAUTIONARY NOTICE: NACE International standards are subject to periodic review, and maybe revised or withdrawn at any time without
9、prior notice. NACE International requires that actionbe taken to reaffirm, revise, or withdraw this standard no later than five years from the date ofinitial publication. The user is cautioned to obtain the latest edition. Purchasers of NACEInternational standards may receive current information on
10、all standards and other NACEInternational publications by contacting the NACE International Membership ServicesDepartment, P.O. Box 218340, Houston, Texas 77218-8340 (telephone +1 281/228-6200).Approved 2000-06-16Approved December 1993NACE InternationalP.O. Box 218340Houston, Texas 77218-8340+1 (281
11、)228-6200ISBN 1-57590-104-8 2000, NACE InternationalNACE Standard TM0193-2000Item No. 21223TM0193-2000NACE International i_ForewordThis standard was written to address a number of testing parameters involved in the laboratorycorrosion testing of clean metal test specimens in static chemical cleaning
12、 solutions at temperaturesbelow 93C (200G71F). Specifically, this standard addresses those parameters not covered in ASTM(1)D 3263,1including surface-to-volume ratio, inhibitor handling, localized corrosion and pitting, andthe reporting procedure, and is for use specifically by those involved in the
13、 industrial cleaningindustry. The intent is that these factors will make the reported corrosion rates more useful forcomparing chemical cleaning solutions and inhibitors.Because chemical cleaning solutions are used over a wide range of applications, no universal testmethod to cover all cases is poss
14、ible. This standard is intended to be used to obtain data relevantto the cleaning of industrial equipment, such as boilers, heat exchangers, piping systems, and tanks.Note that these tests use clean coupons in a clean solution and that the severity of corrosionobtained in these tests will not be the
15、 same as if actual deposits were present.This NACE standard test method was originally prepared in 1993 by NACE Task Group T-3M-5, acomponent of Unit Committee T-3M on Chemical Cleaning, and was revised in 2000 by T-3M. It ispublished by NACE International under the auspices of Group Committee T-3 o
16、n Corrosion Scienceand Technology.In NACE standards, the terms shall, must, should and may are used in accordance with thedefinitions of these terms in the NACE Publications Style Manual, 3rded., Paragraph 8.4.1.8. Shalland must are used to state mandatory requirements. Should is used to state that
17、which isconsidered good and is recommended but is not absolutely mandatory. May is used to state thatwhich is considered optional._(1)American Society for Testing and Materials (ASTM), 100 Barr Harbor Drive, West Conshohocken, PA 19428-2959.TM0193-2000ii NACE International_NACE InternationalStandard
18、Test MethodLaboratory Corrosion Testing of Metals in Static ChemicalCleaning Solutions at Temperatures Below 93C (200F)Contents1. General. 12. Test Equipment and Apparatus 13. Test Solution. 14. Test Specimen Preparation 25. Test Procedure . 36. Test Specimen Handling After Test. 3References 5Append
19、ix A 5_TM0193-2000NACE International 1_Section 1: General1.1 This standard describes a simple method formeasuring the relative corrosiveness of solutions used forchemical cleaning in a static system at temperaturesbelow 93G71C (200G71F). The tests described are conductedwith corrosion test specimens
20、 in the clean condition (i.e.,no deposits). The tests consist of exposing metallic testspecimens to cleaning solutions typically for 6 hoursunder controlled conditions. The test specimens areweighed before and after the test and the corrosion rate iscalculated from the mass loss. Localized corrosion
21、 suchas pitting is also evaluated. Procedures for test specimenhandling and reporting the results for a better comparisonof data among laboratories are also included.1.2 Measurements of corrosion rates in cleaningsolutions obtained by this method should not beextrapolated directly to predict corrosi
22、on rates for metalsurfaces in an operating system. A number of variablesencountered in the chemical cleaning of industrialequipment, such as the nature and amount of deposit,are not readily controlled and can affect corrosion of thematerials exposed to the chemical cleaning solutions.The tests descr
23、ibed in this standard are designed toexclude the variables that can occur when duplicatingfield conditions because these conditions are difficult toreproduce in the laboratory and can make agreementamong different laboratories difficult to obtain. Inlaboratory tests, care should be taken to ensure t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- NACETM01932000LABORATORYCORROSIONTESTINGOFMETALSINSTATICCHEMICALCLEANINGSOLUTIONSATTEMPERATURESBELOW93DEGREESC200DEGREESF

链接地址:http://www.mydoc123.com/p-835889.html