FORD WSS-M4D595-A2-2015 POLYAMIDE 6 (PA 6) 40% GLASS FIBER REINFORCED MOLDING COMPOUND EXTERIOR TO BE USED WITH FORD WSS-M99P1111-A .pdf
《FORD WSS-M4D595-A2-2015 POLYAMIDE 6 (PA 6) 40% GLASS FIBER REINFORCED MOLDING COMPOUND EXTERIOR TO BE USED WITH FORD WSS-M99P1111-A .pdf》由会员分享,可在线阅读,更多相关《FORD WSS-M4D595-A2-2015 POLYAMIDE 6 (PA 6) 40% GLASS FIBER REINFORCED MOLDING COMPOUND EXTERIOR TO BE USED WITH FORD WSS-M99P1111-A .pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、 ENGINEERING MATERIAL SPECIFICATION Date Action Revisions 2015 01 27 N Status No replacement named D. Stark, NA 2005 09 13 Revised Inserted 3.0; Deleted 3.1, 3.2, 3.9, 3.10 & 4 1995 03 10 Activated K. Gerhards Controlled document at www.MATS Copyright 2015, Ford Global Technologies, LLC Page 1 of 5
2、POLYAMIDE 6 (PA 6), 40% GLASS FIBER REINFORCED WSS-M4D595-A2 MOLDING COMPOUND, EXTERIOR NOT TO BE USED FOR NEW DESIGN 1. SCOPE The material defined by this specification is a 40% glass fiber reinforced, UV stabilized, and impact modified molding compound based on a polyamide 6. 2. APPLICATION This s
3、pecification was released originally for material used as door handles. 3. REQUIREMENTS 3.0 STANDARD REQUIREMENTS FOR PRODUCTION MATERIALS Material suppliers and part producers must conform to the Companys Standard Requirements For Production Materials (WSS-M99P1111-A). 3.1.1 All requirements of thi
4、s specification, identified by symbol (s), shall be met with data representing 3 sigma values. 3.3 CONDITIONING AND TEST CONDITIONS All test values indicated herein are based on material and specimens with moisture content not exceeding 0.2% (test according to ISO 960, Method B). Alll test materials
5、 immediately after processing have to be sealed in containers that are impermeable to water vapor. If the moisture content exceeds 0.2%, condition the material for a minimum of 16 h at 40 - 50 C at a reduced pressure below 133 Pa. 3.4 MOLDING COMPOUND (s) 3.4.1 Glass Filler Content 37.5 - 42.5% (ISO
6、 3451/1, test temperature 600 +/- 25 C, test portion 1 g) (s) 3.4.2 Melt Temperature, min 205 - 215 C (ISO 3146, Method C, 10 C/min heating rate) 3.5 MOLDED TEST SPECIMEN 3.5.1 Preparation of Test Specimens Unless otherwise specified all tests shall be carried out on injection molded one-end gated t
7、est specimens. The following dimensions are required: A. 150 min x 10 x 4.0 +/- 0.2 mm (Tensile Bar, ISO 3167) B. 120 x 10 x 4.0 +/- 0.2 mm ENGINEERING MATERIAL SPECIFICATION WSS-M4D595-A2 Copyright 2015, Ford Global Technologies, LLC Page 2 of 5 Specimens with shorter dimensions shall be cut from t
8、he center portion of the test specimen A and/or B. The specimens shall be prepared according to ISO 294. No annealing allowed. 3.5.2 Density 1.43 - 1.49 g/cm3 (ISO 1183, Method A) (s) 3.5.3 Tensile Strength at Yield, min 150 MPa (ISO R 527, 150 minimum x 10 x 4.0 +/- 0.2 mm specimen, 50 mm/min test
9、speed) (s) 3.5.4 Flexural Modulus, min 9.0 GPa (ISO 178, 80 x 10 x 4.0 +/- 0.2 mm specimen, 2 mm/min test speed, 64 mm support span) 3.5.5 Shear Modulus at 23 C 1.8 - 3.1 GPa (ASTM D 4065, forced constant amplitude, fixed frequency of 1 Hz +/- 15%, strain level below 1%. Specimen approx. 60 x 10 x 4
10、.0 +/- 0.2 mm cut from the center of specimen A. Specimen length between clamps 35-40 mm. Soak time at each temperature interval - 3 minutes minimum) Additionally, a Shear Modulus versus Temperature curve shall be plotted for -50 to +200 C temperature range, at 5 C minimum intervals. The plotted cur
11、ve must be within tolerance range shown on page 5. (s) 3.5.6 Impact Strength, Izod, min (ISO 180/1A, 80 x 10 x 4.0 +/- 0.2 mm specimen, 10 specimens for each test) 3.5.6.1 At 23 +/- 2 C 10 kJ/m2 3.5.6.2 At -40 +/- 1 C 7 kJ/m2 The test specimens must be conditioned for minimum of 6 h at the above spe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- FORDWSSM4D595A22015POLYAMIDE6PA640GLASSFIBERREINFORCEDMOLDINGCOMPOUNDEXTERIORTOBEUSEDWITHFORDWSSM99P1111APDF

链接地址:http://www.mydoc123.com/p-753516.html