《ETSI TR 103 313-2017 System Reference document (SRdoc) Technical characteristics for SRD equipment using Ultra Wide Band Sensor technology (UWB) Medical wellness and assisted livin.pdf》由会员分享,可在线阅读,更多相关《ETSI TR 103 313-2017 System Reference document (SRdoc) Technical characteristics for SRD equipment using Ultra Wide Band Sensor technology (UWB) Medical wellness and assisted livin.pdf(36页珍藏版)》请在麦多课文档分享上搜索。
1、 ETSI TR 103 313 V1.1.1 (2017-03) System Reference document (SRdoc); Technical characteristics for SRD equipment using Ultra Wide Band Sensor technology (UWB); Medical, wellness and assisted living applications TECHNICAL REPORT ETSI ETSI TR 103 313 V1.1.1 (2017-03) 2 Reference DTR/ERM-554 Keywords h
2、ealth, SRDoc, UWB ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16 Siret N 348 623 562 00017 - NAF 742 C Association but non lucratif enregistre la Sous-Prfecture de Grasse (06) N 7803/88 Important notice The present document can be d
3、ownloaded from: http:/www.etsi.org/standards-search The present document may be made available in electronic versions and/or in print. The content of any electronic and/or print versions of the present document shall not be modified without the prior written authorization of ETSI. In case of any exi
4、sting or perceived difference in contents between such versions and/or in print, the only prevailing document is the print of the Portable Document Format (PDF) version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document may be su
5、bject to revision or change of status. Information on the current status of this and other ETSI documents is available at https:/portal.etsi.org/TB/ETSIDeliverableStatus.aspx If you find errors in the present document, please send your comment to one of the following services: https:/portal.etsi.org
6、/People/CommiteeSupportStaff.aspx Copyright Notification No part may be reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying and microfilm except as authorized by written permission of ETSI. The content of the PDF version shall not be modified without
7、the written authorization of ETSI. The copyright and the foregoing restriction extend to reproduction in all media. European Telecommunications Standards Institute 2017. All rights reserved. DECTTM, PLUGTESTSTM, UMTSTMand the ETSI logo are Trade Marks of ETSI registered for the benefit of its Member
8、s. 3GPPTM and LTE are Trade Marks of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners. GSM and the GSM logo are Trade Marks registered and owned by the GSM Association. ETSI ETSI TR 103 313 V1.1.1 (2017-03) 3 Contents Intellectual Property Rights 5g3Foreword . 5
9、g3Modal verbs terminology 5g3Introduction 5g31 Scope 6g32 References 6g32.1 Normative references . 6g32.2 Informative references 6g33 Definitions and abbreviations . 8g33.1 Definitions 8g33.2 Abbreviations . 8g34 Comments on the System Reference document . 9g35 Presentation of systems or technologie
10、s . 9g35.1 Background information . 9g35.2 Applications descriptions . 9g35.2.1 Introduction. 9g35.2.2 Wireless Video Transmission in Operating rooms . 11g35.2.2.1 Introduction . 11g35.2.2.2 System requirements . 12g35.2.2.3 Technical description 12g35.2.2.4 Mitigation factors 13g35.2.3 UWB based ca
11、rdio-pulmonary sensor for animals . 13g35.2.3.1 Introduction . 13g35.2.3.2 System requirements . 14g35.2.3.3 Technical description 14g35.2.3.4 Mitigation factors 16g35.2.4 UWB health monitoring application . 16g35.2.4.1 Introduction . 16g35.2.4.2 System requirements . 17g35.2.4.3 Technical descripti
12、on 17g35.2.4.4 Mitigation factors 17g35.2.5 UWB based on-body medical radar 18g35.2.5.1 Introduction . 18g35.2.5.2 System requirements . 19g35.2.5.3 Technical description 19g35.2.5.4 Mitigation factors 19g35.2.6 UWB based remote respiration and heart rate monitor . 20g35.2.6.1 Introduction . 20g35.2
13、.6.2 System requirements . 20g35.2.6.3 Technical description 21g35.2.6.4 Mitigation factors 21g35.3 Classification of medical sensor UWB applications 22g35.3.1 General 22g35.3.2 Non imaging applications (or mode-B echography) . 22g35.3.2.1 Cardiology and vascular 22g35.3.2.2 Pulmonary . 22g35.3.2.3
14、Ear-Nose-Throat medicine 22g35.3.2.4 Gastroenterology . 22g35.3.2.5 Midwifery 22g35.3.3 Imaging applications . 22g35.3.3.1 Introduction . 22g35.3.3.2 Trauma and cerebral vascular care 22g35.3.3.3 Oncology . 23g3ETSI ETSI TR 103 313 V1.1.1 (2017-03) 4 5.3.3.4 UWB radar scanner . 23g36 Current regulat
15、ions . 23g36.1 Overview 23g36.2 Generic regulation 23g36.3 Material sensing devices 24g36.4 Building material analyses applications (BMA) . 25g37 Proposed changes to regulation 25g38 Main conclusions 30g38.1 Business importance . 30g3Annex A: Market information 31g3A.1 Range of applications . 31g3A.
16、2 Market size and value . 31g3A.2.1 Introduction 31g3A.2.2 Market potential Medical communication devices based on UWB 31g3A.2.3 Market potential UWB based animal sensor device . 32g3Annex B: Technical information 33g3Annex C: Expected compatibility issues 34g3C.1 Existing Coexistence studies 34g3An
17、nex D: Bibliography 35g3History 36g3ETSI ETSI TR 103 313 V1.1.1 (2017-03) 5 Intellectual Property Rights IPRs essential or potentially essential to the present document may have been declared to ETSI. The information pertaining to these essential IPRs, if any, is publicly available for ETSI members
18、and non-members, and can be found in ETSI SR 000 314: “Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards“, which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server (https:/ipr.etsi.org
19、/). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become, essential to the pre
20、sent document. Foreword This Technical Report (TR) has been produced by ETSI Technical Committee Electromagnetic compatibility and Radio spectrum Matters (ERM). Modal verbs terminology In the present document “should“, “should not“, “may“, “need not“, “will“, “will not“, “can“ and “cannot“ are to be
21、 interpreted as described in clause 3.2 of the ETSI Drafting Rules (Verbal forms for the expression of provisions). “must“ and “must not“ are NOT allowed in ETSI deliverables except when used in direct citation. Introduction The present document includes necessary information to support the co-opera
22、tion under the MoU between ETSI and the Electronic Communications Committee (ECC) of the European Conference of Post and Telecommunications Administrations (CEPT). Ultra Wide Band technologies enable a very broad new set of applications in the field of medical, assisted living, eHealth and wellness.
23、 The deployment of UWB in the field can be split into the following applications: Communication applications. Sensor and imaging applications. Hybrid application as a combination of sensor and communications. The broad range of potential applications of the technology will be covered in this TR in o
24、rder to classify the requirements and to identify the potential need of specific regulatory activities on CEPT and standardization activities in ETSI. The present document has been created by TC ERM TGUWB. ETSI ETSI TR 103 313 V1.1.1 (2017-03) 6 1 Scope The present document provides information on t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ETSITR1033132017SYSTEMREFERENCEDOCUMENTSRDOCTECHNICALCHARACTERISTICSFORSRDEQUIPMENTUSINGULTRAWIDEBANDSENSORTECHNOLOGYUWBMEDICALWELLNESSANDASSISTEDLIVINPDF

链接地址:http://www.mydoc123.com/p-736412.html