ETSI ES 202 999-2010 SAFETY Remote Power Feeding Installations Safety requirements for the erection and operation of information technology installations with remote power feeding《.pdf
《ETSI ES 202 999-2010 SAFETY Remote Power Feeding Installations Safety requirements for the erection and operation of information technology installations with remote power feeding《.pdf》由会员分享,可在线阅读,更多相关《ETSI ES 202 999-2010 SAFETY Remote Power Feeding Installations Safety requirements for the erection and operation of information technology installations with remote power feeding《.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、 ETSI ES 202 999 V1.1.1 (2010-11)ETSI Standard SAFETY;Remote Power Feeding Installations;Safety requirements for the erection and operationof information technology installationswith remote power feedingETSI ETSI ES 202 999 V1.1.1 (2010-11) 2Reference DES/SAFETY-00007 Keywords control, interface, ma
2、nagement, power, remote, safety, system ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16 Siret N 348 623 562 00017 - NAF 742 C Association but non lucratif enregistre la Sous-Prfecture de Grasse (06) N 7803/88 Important notice Individ
3、ual copies of the present document can be downloaded from: http:/www.etsi.org The present document may be made available in more than one electronic version or in print. In any case of existing or perceived difference in contents between such versions, the reference version is the Portable Document
4、Format (PDF). In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document may be subject to revision or change of status. Information on the curre
5、nt status of this and other ETSI documents is available at http:/portal.etsi.org/tb/status/status.asp If you find errors in the present document, please send your comment to one of the following services: http:/portal.etsi.org/chaircor/ETSI_support.asp Copyright Notification No part may be reproduce
6、d except as authorized by written permission. The copyright and the foregoing restriction extend to reproduction in all media. European Telecommunications Standards Institute 2010. All rights reserved. DECTTM, PLUGTESTSTM, UMTSTM, TIPHONTM, the TIPHON logo and the ETSI logo are Trade Marks of ETSI r
7、egistered for the benefit of its Members. 3GPPTM is a Trade Mark of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners. LTE is a Trade Mark of ETSI currently being registered for the benefit of its Members and of the 3GPP Organizational Partners. GSM and the GSM l
8、ogo are Trade Marks registered and owned by the GSM Association. ETSI ETSI ES 202 999 V1.1.1 (2010-11) 3Contents Intellectual Property Rights 4g3Foreword . 4g31 Scope 5g32 References 5g32.1 Normative references . 5g32.2 Informative references 5g33 Definitions and abbreviations . 6g33.1 Definitions 6
9、g33.2 Abbreviations . 7g34 Limits . 7g34.1 Permitted limit values in maintenance range 7g34.2 Equipment with which limit values are exceeded according to clause 4.1 . 7g35 General requirements . 7g36 Requirements on equipment and lines 8g37 Requirements on operating instructions . 9g38 Recommendatio
10、n of operating instructions (informative) 9g3History 11g3ETSI ETSI ES 202 999 V1.1.1 (2010-11) 4Intellectual Property Rights IPRs essential or potentially essential to the present document may have been declared to ETSI. The information pertaining to these essential IPRs, if any, is publicly availab
11、le for ETSI members and non-members, and can be found in ETSI SR 000 314: “Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards“, which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server
12、(http:/webapp.etsi.org/IPR/home.asp). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, o
13、r may become, essential to the present document. Foreword This ETSI Standard (ES) has been produced by ETSI Technical Committee Telecommunications Equipment Safety (Safety). ETSI ETSI ES 202 999 V1.1.1 (2010-11) 51 Scope The present document contains safety requirements for the erection of informati
14、on technology installations with remote power feeding at an operating a.c. voltage exceeding 50 V (rms value) or an operating d.c. voltage exceeding 120 V, conductor to conductor and/or conductor to earth. It applies in addition to EN 60950-1 3 and EN 60950-21 4 and contains terms, requirements and
15、tests. If special standards are applicable for installations and parts of installations these shall take precedence; for example EN 60950-1 3 and EN 60950-21 4. 2 References References are either specific (identified by date of publication and/or edition number or version number) or non-specific. Fo
16、r specific references, only the cited version applies. For non-specific references, the latest version of the reference document (including any amendments) applies. Referenced documents which are not found to be publicly available in the expected location might be found at http:/docbox.etsi.org/Refe
17、rence. NOTE: While any hyperlinks included in this clause were valid at the time of publication ETSI cannot guarantee their long term validity. 2.1 Normative references The following referenced documents are necessary for the application of the present document. 1 CENELEC EN 60417-1 (1999): “Graphic
18、al symbols for use on equipment. Overview and application“. 2 CENELEC EN 60900 (2004): “Live working. Hand tools for use up to 1 000 V a.c. and 1 500 V d.c“. 3 CENELEC EN 60950-1: “Information technology equipment - Safety - Part 1: General requirements“. 4 CENELEC EN 60950-21: “Information technolo
19、gy equipment - Safety - Part 21: Remote power feeding“. 5 ITU-T Directives concerning the protection of telecommunication lines against harmful effects from electric power and electrified railway lines (volume IV). 6 ITU-T Recommendation K.10: “Low frequency interference due to unbalance about earth
20、 of telecommunication equipment“. 2.2 Informative references The following referenced documents are not necessary for the application of the present document but they assist the user with regard to a particular subject area. Not applicable. ETSI ETSI ES 202 999 V1.1.1 (2010-11) 63 Definitions and ab
21、breviations 3.1 Definitions For the purposes of the present document, the following terms and definitions given in EN 60950-1 3, EN 60950-21 4 and the following apply: load power-fed point: load power-fed point extracts electric power from the remote power feeding circuits via its remote power feedi
22、ng equipment remote power feeding: supply of electric power in the form of direct or alternating current to information technology installations through cables of the associated telecommunication line remote power feeding cables: cables of a telecommunication line which are used for remote power fee
23、ding and may at the same time be telecommunication cables NOTE: They are components of the information technology installation. remote power feeding circuit: circuit which is established by interconnecting remote power feeding devices and cables to form a functional entity NOTE: See also RFT circuit
24、 (remote feeding telecommunication circuit), RFT-C circuits and RFT-V circuits according to EN 60950-21 4. remote power feeding devices: devices used for remote power feeding, e.g. to supply or extract electric power remote power feeding equipment: equipment from which the electric power necessary f
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ETSIES2029992010SAFETYREMOTEPOWERFEEDINGINSTALLATIONSSAFETYREQUIREMENTSFORTHEERECTIONANDOPERATIONOFINFORMATIONTECHNOLOGYINSTALLATIONSWITHREMOTEPOWERFEEDINGPDF

链接地址:http://www.mydoc123.com/p-731113.html