ETSI EN 300 119-4-2004 Environmental Engineering (EE) European telecommunication standard for equipment practice Part 4 Engineering requirements for subracks in miscellaneous racks.pdf
《ETSI EN 300 119-4-2004 Environmental Engineering (EE) European telecommunication standard for equipment practice Part 4 Engineering requirements for subracks in miscellaneous racks.pdf》由会员分享,可在线阅读,更多相关《ETSI EN 300 119-4-2004 Environmental Engineering (EE) European telecommunication standard for equipment practice Part 4 Engineering requirements for subracks in miscellaneous racks.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、 ETSI EN 300 119-4 V2.1.1 (2004-09)European Standard (Telecommunications series) Environmental Engineering (EE);European telecommunication standard for equipment practice;Part 4: Engineering requirements forsubracks in miscellaneous racks and cabinetsETSI ETSI EN 300 119-4 V2.1.1 (2004-09) 2 Referen
2、ce REN/EE-TMG006 Keywords equipment practice, environment, rack ETSI 650 Route des Lucioles F-06921 Sophia Antipolis Cedex - FRANCE Tel.: +33 4 92 94 42 00 Fax: +33 4 93 65 47 16 Siret N 348 623 562 00017 - NAF 742 C Association but non lucratif enregistre la Sous-Prfecture de Grasse (06) N 7803/88
3、Important notice Individual copies of the present document can be downloaded from: http:/www.etsi.org The present document may be made available in more than one electronic version or in print. In any case of existing or perceived difference in contents between such versions, the reference version i
4、s the Portable Document Format (PDF). In case of dispute, the reference shall be the printing on ETSI printers of the PDF version kept on a specific network drive within ETSI Secretariat. Users of the present document should be aware that the document may be subject to revision or change of status.
5、Information on the current status of this and other ETSI documents is available at http:/portal.etsi.org/tb/status/status.asp If you find errors in the present document, please send your comment to one of the following services: http:/portal.etsi.org/chaircor/ETSI_support.asp Copyright Notification
6、No part may be reproduced except as authorized by written permission. The copyright and the foregoing restriction extend to reproduction in all media. European Telecommunications Standards Institute 2004. All rights reserved. DECTTM, PLUGTESTSTM and UMTSTM are Trade Marks of ETSI registered for the
7、benefit of its Members. TIPHONTMand the TIPHON logo are Trade Marks currently being registered by ETSI for the benefit of its Members. 3GPPTM is a Trade Mark of ETSI registered for the benefit of its Members and of the 3GPP Organizational Partners. ETSI ETSI EN 300 119-4 V2.1.1 (2004-09) 3 Contents
8、Intellectual Property Rights4 Foreword.4 1 Scope 5 2 References 5 3 Dimensions for subracks 5 4 Accessibility.6 5 Weight 6 5.1 Unequipped subrack.6 5.2 Equipped subrack .6 6 Electromagnetic compatibility and electrostatic discharge requirements 6 Annex A (informative): Illustrative figures8 Annex B
9、(informative): Bibliography.10 History 11 ETSI ETSI EN 300 119-4 V2.1.1 (2004-09) 4 Intellectual Property Rights IPRs essential or potentially essential to the present document may have been declared to ETSI. The information pertaining to these essential IPRs, if any, is publicly available for ETSI
10、members and non-members, and can be found in ETSI SR 000 314: “Intellectual Property Rights (IPRs); Essential, or potentially Essential, IPRs notified to ETSI in respect of ETSI standards“, which is available from the ETSI Secretariat. Latest updates are available on the ETSI Web server (http:/webap
11、p.etsi.org/IPR/home.asp). Pursuant to the ETSI IPR Policy, no investigation, including IPR searches, has been carried out by ETSI. No guarantee can be given as to the existence of other IPRs not referenced in ETSI SR 000 314 (or the updates on the ETSI Web server) which are, or may be, or may become
12、, essential to the present document. Foreword This European Standard (Telecommunications series) has been produced by ETSI Technical Committee Environmental Engineering (EE). The present document is part 4 of a multi-part deliverable aimed at setting out, on a common basis, the engineering requireme
13、nts for telecommunication practice, for housing equipment forming part of a public telecommunications network. EN 300 119-1 2 is a general introduction and explains the terminology used. EN 300 119-2 3 specifies the engineering requirements for racks and cabinets and EN 300 119-3 4 specifies the eng
14、ineering requirements for miscellaneous racks and cabinets. EN 300 119-5 5 covers the preferred thermal management solutions for subracks, racks/cabinets and miscellaneous racks/cabinets installed indoors in restricted access locations, for the removal of heat dissipated by one or more subracks in a
15、n rack complying to the requirements of this multi-part standard. The present document specifies the engineering requirements for subracks mounted in miscellaneous racks and cabinets. The present document applies to all telecommunications equipment forming part of the public telecommunications netwo
16、rk. Illustrative figures are contained in annex A. The present document is part 4 of a multi-part deliverable. Full details of the entire series can be found in part 1 2. National transposition dates Date of adoption of this EN: 24 September 2004 Date of latest announcement of this EN (doa): 31 Dece
17、mber 2004 Date of latest publication of new National Standard or endorsement of this EN (dop/e): 30 June 2005 Date of withdrawal of any conflicting National Standard (dow): 30 June 2005 ETSI ETSI EN 300 119-4 V2.1.1 (2004-09) 5 1 Scope The present document details requirements for subracks for use i
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ETSIEN30011942004ENVIRONMENTALENGINEERINGEEEUROPEANTELECOMMUNICATIONSTANDARDFOREQUIPMENTPRACTICEPART4ENGINEERINGREQUIREMENTSFORSUBRACKSINMISCELLANEOUSRACKSPDF

链接地址:http://www.mydoc123.com/p-727869.html