EN ISO 12048-2000 en Packaging - Complete Filled Transport Packages - Compression and Stacking Tests Using a Compression Tester《包装 完全满运输包装件 利用压缩试验机的压缩试验和堆积试验 ISO 12048-1994 代替EN 22.pdf
《EN ISO 12048-2000 en Packaging - Complete Filled Transport Packages - Compression and Stacking Tests Using a Compression Tester《包装 完全满运输包装件 利用压缩试验机的压缩试验和堆积试验 ISO 12048-1994 代替EN 22.pdf》由会员分享,可在线阅读,更多相关《EN ISO 12048-2000 en Packaging - Complete Filled Transport Packages - Compression and Stacking Tests Using a Compression Tester《包装 完全满运输包装件 利用压缩试验机的压缩试验和堆积试验 ISO 12048-1994 代替EN 22.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、STDmBSI BS EN IS0 12048-ENGL 2001 1b24bb9 0892200 073 BRITISH STANDARD BS EN IS0 12048:2001 Packaging - Complete, filled transport packages - Compression and stacking tests using a compression tester The European Standard EN IS0 12048:2000 has the status of a British Standard ICs 55.180.40 NO COPYIN
2、G WITHOUT BSI PERMISSION EXCEPT AS PERMIITED BY COPYRIGH“ LAW STD*BSI BS EN IS0 L2048-ENGL 2101 M 1624669 0892201 TOT BS EN IS0 12048:2001 direction of the Consumer AmdNo. products and Services Sector Committee, was published under the authority of the Standards Committee and comes into effect on 15
3、 February 2001 O BSI 02-2001 National foreword Date Comments This British Standad is the official English language version of EN IS0 12048:2000. It is identical with IS0 12048:1994. It supersedes BS IS0 12W1994 which is withdrawn. The UK participation in its preparation was entrusted by Technical Co
4、mmittee PKW/l, Packaging generalities, to Subcommittee PKW/1/4, Test methods, which has the responsibility to: - aid enquirers to understand the te* - present to the responsible inkrnatio or in the case of a stacking test, a predetermined load is applied for a predetermined time or until failure occ
5、urs. Apparatus 4.1 Compression tester, motor-driven, platen-type, capable of applying load through uniform movement of one or both platens at a relative speed of 10 mm/min 2 3 mm/min. NOTES 1 The comparison between results obtained from apparatus operated at other speeds (for example 12,5 mdmin I 2,
6、5 mdmin) and results obtained at 10 mdmin 2 3 mmlmin is not recommended. 2 For certain packagings, such as metal drums or wooden crates, lower speeds may be required to prevent load peaks in excess of the predetermined value. 4.1.1 Platens Each platen shall be - flat: a) with a tolerance of 1 part i
7、n 1 O00 for surface areas 1 m2, such that when placed horizontally the difference in height between the lowest and highest points of the platen does not exceed 1 mm; - dimensioned so as to extend over the whole area of that side of the test package or interposed devices with which it is in contact;
8、1) To be published. (Revision of IS0 2233:1986) 1 STD.BSI BS EN IS0 L204B-ENGL 2001 3b24bb9 0892206 591 EN IS0 12048:2000 - rigid, so as not to deform by more than 1 mm at any point when the tester applies a load of 75 % of its maximum rating, either to a centrally placed 100 mm X 100 mm X 100 mm bl
9、ock having suf- ficient strength to accept the load without failure, or to four similar blocks placed at the four corners, in the case of swivel-mounted platens. One platen shall remain horizontal, within a tolerance of two parts per 1000, at all times during the test. The other platen shall be eith
10、er rigidly mounted so as to remain horizontal within two parts per 1 O00 at all times during the test, or be held by a universal joint at its centre and so be free to tilt in any direction. The working surfaces of the platens may be locally recessed for fixing bolts etc. 4.1.2 Means of applying a pr
11、edetermined load for a predetermined time, with a fluctuation not exceeding +- 4 % of the predetermined load and with no more relative movement of the platens than is necessary to maintain this load during any vertical displacement of the upper platen. 4.2 Recording device or other means of indicati
12、ng applied load and platen displacement, with a percentage of error not exceeding 2 % of the load and an accuracy for recording platen displacement of 2 1 mm. 4.3 Means of measuring package dimensions with an accuracy of I 1 mm. 5 Package preparation The test package shall normally be filled with it
13、s intended contents. However, simulated or dummy contents may be used, on condition that the dimensions and physical properties of such contents shall be as close as possible to those of the intended contents. Ensure that the test package is closed normally, as if ready for distribution. If simulate
14、d or dummy contents are used, ensure that the normal method of closure is still employed. 6 Conditioning The package shall be conditioned in accordance with one of the sets of conditions given in IS0 2233. 7 Procedure Wherever possible the test shall be carried out in the same atmospheric conditions
15、 as used for condition- ing, where this is critical to the materials or application of the package. In other circumstances, the test shall be carried out in atmospheric conditions which are as near as practicable to those used for conditioning. When possible, carry out the test on five replicate pac
16、kages. 7.1 Compression test 7.1.1 Weigh the package and its contents separately, fill the package and measure the external dimensions of the filled package. 7.1.2 Place the test package centrally on the lower platen of the test machine (4.11, in the predetermined attitude. When the compression load
17、is not to be applied over the whole surface of the package which is being tested, appropriate devices should be suitably interposed between the package and platen of the compression tester in order to simulate the conditions met in distribution systems when applying these compression loads. 7.1.3 Ap
18、ply the load by relative movement of the platens at the appropriate speed, in such a way that peaks in excess of the predetermined load do not occur, until the predetermined value is reached or until collapse occurs, whichever is first. If collapse occurs first, record the value of the load reached.
19、 In measuring deformation, the initial reading (the datum point), unless otherwise specified, shall be taken at an initial load which is a function of the expected average compression load according to table 1. Table 1 - Datum points Average compression load N 101 -200 201 - 1 O00 1 O01 -2 O00 2 O01
20、 - 10 O00 10001 -20000 20 O01 - 100 O00 etc. Datum point N 10 25 loo 250 1 O00 2 500 etc. 7.1.4 If required, maintain the Predetermined load for a predetermined time or until collapse occurs, whichever is first. If collapse occurs first, record the value of the time elapsed. 7.1.5 Remove the load by
21、 movement of the platens, examine the package and, if collapse has occurred, measure its dimensions and examine the contents for damage. 7.1.6 Where it is desired to measure the ability of a complete, filled transport package to resist external 2 STD.BSI BS EN IS0 l.12048-ENGL 2001 Lb24bb9 0892207 4
22、28 H EN IS0 12048:2000 compressive loads applied to opposite edges or of the package and its fittings, cushioning, corners of the package, follow the procedure in 7.1.1 blocking, closure or reinforcing arrangements; to 7.1.5, using a tester in which the platens are not free to tilt. e) description o
23、f the contents - if simulated or dummy contents were used, full details shall be given; 7.2 Stacking test NOTE 3 A stacking test on a complete, filled transport package, using one of three methods of applying a static load, is given in IS0 2234. 7.2.1 Proceed as in 7.1.1 to 7.1.3 and maintain the pr
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ENISO120482000ENPACKAGINGCOMPLETEFILLEDTRANSPORTPACKAGESCOMPRESSIONANDSTACKINGTESTSUSINGACOMPRESSIONTESTER

链接地址:http://www.mydoc123.com/p-724705.html