EN 60519-21-2009 en Safety in electroheat installations - Part 21 Particular requirements for resistance heating equipment - Heating and melting glass equipment《电热设备的安全 第21部分 电阻加热设.pdf
《EN 60519-21-2009 en Safety in electroheat installations - Part 21 Particular requirements for resistance heating equipment - Heating and melting glass equipment《电热设备的安全 第21部分 电阻加热设.pdf》由会员分享,可在线阅读,更多相关《EN 60519-21-2009 en Safety in electroheat installations - Part 21 Particular requirements for resistance heating equipment - Heating and melting glass equipment《电热设备的安全 第21部分 电阻加热设.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、Safety in electroheatinstallations Part 21: Particular requirements forresistance heating equipment Heating and melting glass equipmentBS EN 60519-21:2009raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI British StandardsNational forewordThis Britis
2、h Standard is the UK implementation of EN 60519-21:2009. It isidentical to IEC 60519-21:2008. It supersedes BS EN 60519-21:1998 which iswithdrawn.The UK participation in its preparation was entrusted to Technical CommitteePEL/27, Electroheating.A list of organizations represented on this committee c
3、an be obtained onrequest to its secretary.This publication does not purport to include all the necessary provisions of acontract. Users are responsible for its correct application. BSI 2009ISBN 978 0 580 57527 3ICS 25.180.10BRITISH STANDARDBS EN 60519-21:2009Compliance with a British Standard cannot
4、 confer immunity fromlegal obligations.This British Standard was published under the authority of the StandardsPolicy and Strategy Committee on Amendments issued since publicationAmd. No. Date Text affectedEUROPEAN STANDARD EN 60519-21 NORME EUROPENNE EUROPISCHE NORM January 2009 CENELEC European Co
5、mmittee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Central Secretariat: avenue Marnix 17, B - 1000 Brussels 2009 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC
6、 members. Ref. No. EN 60519-21:2009 E ICS 25.180.10 Supersedes EN 60519-21:1998English version Safety in electroheat installations - Part 21: Particular requirements for resistance heating equipment - Heating and melting glass equipment (IEC 60519-21:2008) Scurit dans les installations lectrothermiq
7、ues - Partie 21: Exigences particulires pour les installations de chauffage par rsistance - Installations lectrothermiques de fusion de verre (CEI 60519-21:2008) Sicherheit in Elektrowrmeanlagen - Teil 21: Besondere Anforderungen an Einrichtungen mit Widerstandserwrmung - Einrichtungen zum Erwrmen u
8、nd Schmelzen von Glas (IEC 60519-21:2008) This European Standard was approved by CENELEC on 2008-12-01. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard without any alterat
9、ion. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Central Secretariat or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any other language made by tran
10、slation under the responsibility of a CENELEC member into its own language and notified to the Central Secretariat has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, F
11、inland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 60519-21:2009EN 60519-21:2009 2 Foreword The text of document 27/6
12、30/CDV, future edition 2 of IEC 60519-21, prepared by IEC TC 27, Industrial electroheating equipment, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC as EN 60519-21 on 2008-12-01. This European Standard supersedes EN 60519-21:1998. The significant changes with respect to E
13、N 60519-21:1998 are as follows: EN 60519-1:2003 and EN 60519-2:2006 have been taken into account; definitions have been brought into line with IEC 60050-841:2004. The following dates were fixed: latest date by which the EN has to be implemented at national level by publication of an identical nation
14、al standard or by endorsement (dop) 2009-09-01 latest date by which the national standards conflicting with the EN have to be withdrawn (dow) 2011-12-01 This standard is to be used in conjunction with EN 60519-2:2006. It is intended to specify particular requirements for resistance heating and melti
15、ng glass equipment. This Part 21 supplements or modifies the corresponding clauses of EN 60519-2, so as to convert it into a European Standard. Where a particular subclause of Part 2 is not mentioned in this Part 21, that subclause applies as far as is reasonable. Where this standard states “additio
16、n“, “modification“ or “replacement“, the relevant text of Part 2 is to be adapted accordingly. NOTE Subclauses and notes which are additional to those in Part 2 are numbered starting from 101. _ Endorsement notice The text of the International Standard IEC 60519-21:2008 was approved by CENELEC as a
17、European Standard without any modification. _ BS EN 60519-21:2009 2 60519-21 IEC:2008 CONTENTS 1 Scope and object5 2 Normative references .5 3 Terms and definitions .5 4 Classification of electroheat equipment according to voltage bands6 5 Classification of electroheat equipment according to frequen
18、cy bands6 6 General requirements.6 7 Isolation and switching .6 8 Connection to the supply network and internal connections 6 9 Protection against electric shock 6 10 Protection against overcurrent7 11 Equipotential bonding.7 12 Control circuits and control functions7 13 Protection against thermal i
19、nfluences .7 14 Risk of fire and danger of explosion7 15 Marking, labelling and technical documentation7 16 Information on inspection and commissioning and instructions for utilization and maintenance of electroheat installations .7 BS EN 60519-21:200960519-21 IEC:2008 5 SAFETY IN ELECTROHEAT INSTAL
20、LATIONS Part 21: Particular requirements for resistance heating equipment Heating and melting glass equipment 1 Scope and object Replacement: This part of IEC 60519 is applicable to indirect resistance heating equipment for the heating and melting of glass, operating in voltage bands 1 and 2. These
21、particular requirements also apply to equipment for direct resistance heating and melting of glass by means of current introduced by electrodes passing through the charge to be heated. The object of this standard is the determination of safety requirements for both indirect and direct resistance hea
22、ting equipment for the heating and melting of glass. NOTE Extraction of liquid glass or a similar material at the extraction point is part of the production process and does not constitute part of the operation of the electroheat equipment. This standard covers the safety aspects of electrical parts
23、 also in the case when electrical heating is combined with other means of heating, for example liquid fuel heating. These requirements do not apply to equipment for direct resistance heating, where, owing to the technology used, IEC 60519-3, IEC 60519-4 and IEC 60519-8 are applicable. 2 Normative re
24、ferences This Clause of part 2 is applicable. 3 Terms and definitions This Clause of part 2 applies except as follows: Addition: 3.101 glass-melting furnace (indirect resistance heating) furnace in which glass is melted by means of indirect resistance heating 3.102 pot furnace melting equipment in w
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN60519212009ENSAFETYINELECTROHEATINSTALLATIONSPART21PARTICULARREQUIREMENTSFORRESISTANCEHEATINGEQUIPMENTHEATINGANDMELTINGGLASSEQUIPMENT

链接地址:http://www.mydoc123.com/p-718329.html