EN 13124-1-2001 en Windows Doors and Shutters - Explosion Resistance - Test Method - Part 1 Shock Tube《门窗和遮板 防爆的试验方法 第1部分 冲击管》.pdf
《EN 13124-1-2001 en Windows Doors and Shutters - Explosion Resistance - Test Method - Part 1 Shock Tube《门窗和遮板 防爆的试验方法 第1部分 冲击管》.pdf》由会员分享,可在线阅读,更多相关《EN 13124-1-2001 en Windows Doors and Shutters - Explosion Resistance - Test Method - Part 1 Shock Tube《门窗和遮板 防爆的试验方法 第1部分 冲击管》.pdf(14页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD Windows, doors and shutters - Explosion resistance - Test method - Part 1: Shock tube O The European Standard EN 13124-1:2001 has the status of a British Standard ICs 13.230; 91.060.50 BS EN 1 3 124- 1 :200 1 NO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAW BS
2、EN 13124-1:2001 Amd. No. National foreword Date Comments This British Standard, having been prepared under the direction of the Sector Committee for Building and Civil Engineering, was published under the authority of the Standards Committee and comes into effect on 15 June 2001 This British Standar
3、d is the official English language version of The UK participation in its preparation was entrusted to Technical Committee B/538, Doors, windows, shutters, hardware, which has the responsibility to: EN 13 124- 1 :2001. - - aid enquirers to understand the text; present to the responsible European com
4、mittee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related international and European developments and promulgate them in the UK. - A list of organizations represented on this committee can be obtained on request to its secretary. Cross-r
5、eferences The British Standards which implement international or European publications referred to in this document may be found in the BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Find” facility of the BSI Standards Electronic C
6、atalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document
7、comprises a front cover, an inside front cover, the EN title page, pages 2 to 11 and a back cover. The BSI copyright date displayed in this document indicates when the document was last issued. Amendments issued since publication O BSI 06-2001 ISBN O 580 37703 2 EUROPEAN STANDARD NORME EUROPENNE EUR
8、OPISCHE NORM O EN 13124-1 April 2001 ICs 13.230; 91 .O6050 English version Windows, doors and shutters - Explosion resistance - Test method - Part 1 : Shock tube Fen tres, portes et fermetures - Rsistance lexplosion - Mthode dessai - Partie 1: Tube effet de souffle (shock tube) Fenster, Tren und Abs
9、chlsse - Sprengwirkungshemmun - Prfverfahren - Teil 1 : Stossrohr 0 This European Standard was approved by CEN on 7 March 2001. CEN members are bound to comply with the CENKENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard
10、without any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the Management Centre or to any CEN member. This European Standard exists in three official versions (English, French, German). A version in any other language
11、 made by translation under the responsibility of a CEN member into its own language and notified to the Management Centre has the same status as the official versions. CEN members are the national standards bodies of Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Icelan
12、d, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and United Kingdom. EUROPEAN COMMEE FOR STANDARDIZATION COMITE EUROPEEN DE NORMALISATION EUROPISCHES KOMITEE FR NORMUNG Management Centre: rue de Stassari, 36 8-1050 Brussels O 2001 CEN All rights of exploitatio
13、n in any form and by any means reserved worldwide for CEN national Members. Ref. No. EN 13124-1:2001 E Page 2 EN 131 24-1 12001 Contents Page Foreword . 3 1 Scope . 4 2 Normative references . 4 Terms and definitions . 4 3 4 Requirements 6 6 Test specimen . 7 7 Procedure 7 8 Sequence of test . 8 9 Ev
14、aluation of results . 8 10 Test report . 9 11 Test report summary 10 5 Apparatus 6 Page 3 EN 13124-112001 Foreword This European Standard has been prepared by Technical Committee CENTTC 33, “Windows, doors, shutters, building hardware and curtain walling“, the secretariat of which is held by AFNOR.
15、This European Standard shall be given the status of a national standard, either by publication of an identical text or by endorsement, at the latest by October 2001, and conflicting national standards shall be withdrawn at the latest by October 2001. According to the CENKENELEC Internal Regulations,
16、 the national standards organizations of the following countries are bound to implement this European Standard: Austria, Belgium, Czech Republic, Denmark, Finland, France, Germany, Greece, Iceland, Ireland, Italy, Luxembourg, Netherlands, Norway, Portugal, Spain, Sweden, Switzerland and the United K
17、ingdom. Page 4 1 Scope EN 131 24-1 12001 This European Standard specifies a conventional test procedure to permit classification of the explosion resistance of windows, doors and shutter together with their infills. This European Standard concerns a method of test against blast waves generated by us
18、ing a shock tube facility to simulate a high explosive detonation in the order of 100 kg to 2 500 kg TNT at distances from about 35 m to 50 m . This European Standard covers only the behaviour of the complete unit including infill, frame and fixings as tested. It gives no information on the ability
19、of the surrounding wall or building structure to resist the direct or transmitted forces. If the windows, doors and shutters are intended for specific conditions of climate, specific test conditions may be required. It gives no information on the behaviour of the units subjected to other types of lo
20、ading. NOTE which is at least equal to that of the window or door. Care should be taken to ensure that all joints between the wall and the window or door have protect. 2 Normative references This European Standard incorporates by dated or undated reference, provisions from other publications. These
21、normative references are cited at the appropriate places in the text and the publications are listed hereafter. For dated references, subsequent amendments to or revisions of any of these publications apply to this European Standard only when incorporated in it by amendment or revision. For undated
22、references the latest edition of the publication referred to applies (including am end men ts) . EN 13123-1 12001 Windows, doors and shutters - Explosion resistance - Requirements and classification - Part 1 : Shock tube 3 Terms and definitions a For the purposes of this European Standard, the follo
23、wing terms and definitions apply. 3.1 test specimen sample prepared and submitted for testing 3.2 attack face the face of the test specimen designed to face the explosion 3.3 rear face the opposite side of the test specimen to the attack face a Page 5 EN 131 24-1 12001 3.4 breach an opening created
24、by distortion in the test specimen during the test and evident after the test exceeding that specified in clause 9. Any opening created by a fragment of the specimen passing through or ejected from the test specimen 3.5 explosive pressure resistance EXR resistance offered against a defined pressure
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- EN1312412001ENWINDOWSDOORSANDSHUTTERSEXPLOSIONRESISTANCETESTMETHODPART1SHOCKTUBE 门窗 防爆 试验 方法 部分 冲击 PDF

链接地址:http://www.mydoc123.com/p-707266.html