DLA SMD-5962-92144 REV N-2009 MICROCIRCUIT HYBRID LINEAR 12 VOLT DUAL CHANNEL DC DC CONVERTER.pdf
《DLA SMD-5962-92144 REV N-2009 MICROCIRCUIT HYBRID LINEAR 12 VOLT DUAL CHANNEL DC DC CONVERTER.pdf》由会员分享,可在线阅读,更多相关《DLA SMD-5962-92144 REV N-2009 MICROCIRCUIT HYBRID LINEAR 12 VOLT DUAL CHANNEL DC DC CONVERTER.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、 REVISIONS LTR DESCRIPTION DATE (YR-MO-DA) APPROVED A Changes in accordance with NOR 5962-R112-93. 93-03-22 K. Cottongim B Changes in accordance with NOR 5962-R159-93. 93-05-11 K. Cottongim C Added case outline Z. Redrew entire document. 95-06-15 K. Cottongim D Added RadHard and Class K devices. Add
2、ed RadHard requirements. Redrew entire document. -sld 97-10-29 K. A. Cottongim E Table I; Changed the min and max limits for Radhard levels L, R device type 02 for the following tests +VOUT, -VOUT. Changed the max limits for VRLINE, VRLOAD, IIN, and Eff. For IRIPtest separate subgroups 1, 2, 3 to su
3、bgroup 1 for device type 01 max limit of 60 mAp-p and for subgroups 2 and 3 the max limit of 100 mAp-p. For the IRIPtest separate subgroups 1, 2, 3 to subgroup 1 for device type 02 max limit of 80 mAp-p and for subgroups 2 and 3 the max limit of 120 mAp-p. -sld 98-02-04 K. A. Cottongim F Made correc
4、tion to paragraph 4.3.5.a. Updated paragraph 1.2.3 to define the five reliability class levels. Made changes to table I format. -sld 01-03-21 Raymond Monnin G Added case outline Y, bathtub style package. -sld 01-08-21 Raymond Monnin H Made changes to XREG, VOTLOAD, and TTLOADin table I. Made additio
5、ns to footnotes 3/ and 5/ for table I. -gjc 02-09-24 Raymond Monnin J Table I; TTLOAD. Take out redundant values for +VOUTand -VOUT. For TTLOAD, 200s Max. on device type 01 was erroneously listed for +VOUTand -VOUT. Correct value is 500 s. Also, on Table I; change output current (IOUT) for device ty
6、pe 01 from 0.875 A to 1.125 A to agree with footnote 2/. 90% of 15W is 13.5 W and for 12 VOUTis 1.125 A. -gjc 03-11-06 Raymond Monnin K Figure 1; case outline X. Change the max limit for dimension “D“ from 1.455 inches to 1.460 inches and for dimension “E“ change the max limit from 1.125 inches to 1
7、.130 inches. Editorial changes throughout. -sld 04-08-19 Raymond Monnin L Add paragraph 1.5 and note 2. Table I, add note for enhanced low dose rate effects. Paragraph 4.3.5.a, correct paragraph to add component tested dose rate. -sld 07-01-08 Raj Pithadia M Add RHA level P to device type 02 in para
8、graphs 1.3, 1.5, 4.3.5 (table), table I, and SMD bulletin. Add paragraph 3.2.3. -gz 07-06-05 Robert M. Heber N Added footnote 1 to table II, under group C end-point electricals. Updated drawing paragraphs. -sld 09-08-06 Charles F. Saffle REV SHEET REV N SHEET 15 REV STATUS REV N N N N N N N N N N N
9、N N N OF SHEETS SHEET 1 2 3 4 5 6 7 8 9 10 11 12 13 14 PMIC N/A PREPARED BY Steve L. Duncan DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 http:/www.dscc.dla.mil/ STANDARD MICROCIRCUIT DRAWING CHECKED BY Michael Jones THIS DRAWING IS AVAILABLE FOR USE BY ALL DEPARTMENTS APPROVED BY Gregory
10、 A. Lude MICROCIRCUIT, HYBRID, LINEAR, 12 VOLT, DUAL CHANNEL, DC/DC CONVERTER AND AGENCIES OF THE DEPARTMENT OF DEFENSE DRAWING APPROVAL DATE 92-08-18 AMSC N/A REVISION LEVEL N SIZE A CAGE CODE 67268 5962-92144 SHEET 1 OF 15 DSCC FORM 2233 APR 97 5962-E379-09Provided by IHSNot for ResaleNo reproduct
11、ion or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-92144 DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION LEVEL N SHEET 2 DSCC FORM 2234 APR 97 1. SCOPE 1.1 Scope. This drawing documents five product assurance classes as defined in par
12、agraph 1.2.3 and MIL-PRF-38534. A choice of case outlines and lead finishes which are available and are reflected in the Part or Identifying Number (PIN). When available, a choice of radiation hardness assurance levels are reflected in the PIN. 1.2 PIN. The PIN shall be as shown in the following exa
13、mple: 5962 - 92144 01 H X X Federal RHA Device Device Case Lead stock class designator type class outline finish designator (see 1.2.1) (see 1.2.2) designator (see 1.2.4) (see 1.2.5) / (see 1.2.3) / Drawing number 1.2.1 Radiation hardness assurance (RHA) designator. RHA marked devices shall meet the
14、 MIL-PRF-38534 specified RHA levels and shall be marked with the appropriate RHA designator. A dash (-) indicates a non-RHA device. 1.2.2 Device type(s). The device type(s) identify the circuit function as follows: Device type Generic number Circuit function 01 MHF+2812D/883,MHF+2812DF/883 DC-DC con
15、verter, 15 W, 12 V output 02 SMHF2812D,SMHF2812DF DC-DC converter, 15 W, 12 V output 1.2.3 Device class designator. This device class designator shall be a single letter identifying the product assurance level. All levels are defined by the requirements of MIL-PRF-38534 and require QML Certification
16、 as well as qualification (Class H, K, and E) or QML Listing (Class G and D). The product assurance levels are as follows: Device class Device performance documentation K Highest reliability class available. This level is intended for use in space applications. H Standard military quality class leve
17、l. This level is intended for use in applications where non-space high reliability devices are required. G Reduced testing version of the standard military quality class. This level uses the Class H screening and In-Process Inspections with a possible limited temperature range, manufacturer specifie
18、d incoming flow, and the manufacturer guarantees (but may not test) periodic and conformance inspections (Group A, B, C and D). E Designates devices which are based upon one of the other classes (K, H, or G) with exception(s) taken to the requirements of that class. These exception(s) must be specif
19、ied in the device acquisition document; therefore the acquisition document should be reviewed to ensure that the exception(s) taken will not adversely affect system performance. D Manufacturer specified quality class. Quality level is defined by the manufacturers internal, QML certified flow. This p
20、roduct may have a limited temperature range. Provided by IHSNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-STANDARD MICROCIRCUIT DRAWING SIZE A 5962-92144 DEFENSE SUPPLY CENTER COLUMBUS COLUMBUS, OHIO 43218-3990 REVISION LEVEL N SHEET 3 DSCC FORM 2234 APR 97 1.2.4
21、 Case outline(s). The case outline(s) are as designated in MIL-STD-1835 and as follows: Outline letter Descriptive designator Terminals Package style X See figure 1 8 Dual-in-line, Platform Y See figure 1 8 Dual-in-line, Bathtub Z See figure 1 8 Flange mount, Platform 1.2.5 Lead finish. The lead fin
22、ish shall be as specified in MIL-PRF-38534. 1.3 Absolute maximum ratings. 1/ Input voltage range -0.5 V dc to +50 V dc Power dissipation (PD): Device types 01 and 02 (non-RHA) 6 W Device type 02 (RHA levels P, L and R) . 8.5 W Output power . 15.26 W Lead soldering temperature (10 seconds) . +300C St
23、orage temperature range -65C to +150C 1.4 Recommended operating conditions. Input voltage range +16 V dc to +40 V dc Case operating temperature range -55C to +125C 1.5 Radiation features. Maximum total dose available (dose rate = 9 rad(Si)/s): Device type 02 (RHA levels P, L and R) 100 krad (Si) 2/
24、2. APPLICABLE DOCUMENTS 2.1 Government specification, standards, and handbooks. The following specification, standards, and handbooks form a part of this drawing to the extent specified herein. Unless otherwise specified, the issues of these documents are those cited in the solicitation or contract.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLASMD596292144REVN2009MICROCIRCUITHYBRIDLINEAR12VOLTDUALCHANNELDCDCCONVERTERPDF

链接地址:http://www.mydoc123.com/p-700156.html