1、INCH-POUND MIL-PRF-8805/3L 23 March 2009 SUPERSEDING MIL-PRF-8805/K 14 March 2003 PERFORMANCE SPECIFICATION SHEET SWITCHES, PUSH, 10 AMPERES OR LOW LEVEL, DUSTTIGHT This specification is approved for use by all Departments and Agencies of the Department of Defense. The complete requirements for acqu
2、iring the switches described herein shall consist of this specification and the latest issue of MIL-PRF-8805. FIGURE 1. Configuration and dimensions.625 .006 DIA BUTTON STYLE SHOWN IS FOR MOMENTARY ACTION SWITCHES (SEE PUSH-PULL CONFIGURATION) AMSC N/A FSC 5930 Provided by IHSNot for ResaleNo reprod
3、uction or networking permitted without license from IHS-,-,-MIL-PRF-8805/3L 2 .375 Inches mm Inches mm Inches mm Inches mm .001 0.03 .031 0.79 .250 6.35 .623 15.82 .004 0.10 .047 1.19 .312 7.92 .625 15.88 .006 0.15 .062 1.57 .333 8.46 .640 16.26 .015 0.38 .094 2.39 .375 9.53 .688 17.48 .016 0.41 .12
4、5 3.18 .438 11.13 .739 18.77 .019 0.48 .156 3.96 .500 12.70 .875 22.23 .020 0.51 .187 4.75 .562 14.27 1.375 34.93 .022 0.56 .188 4.78 NOTES: 1. Dimensions are in inches. 2. Unless otherwise stated, tolerance is .010 (0.25 mm). 3. Mounting thread .625-24 UNEF-2A applies to type C, F, G, and H. All th
5、reads to be within .10 2.54 mm) of shoulder. 4. All terminal threads are .086-56UNC-28. 5. Hardware for each terminal includes one screw, one terminal lug, and one lockwasher. 6. Types C, F, G, and H shall be furnished with suitable mounting hardware. 7. Overall height of switch with push-pull activ
6、ator is 1.530 (38.66 mm) maximum in extended position. 8. Metric equivalents are given for general information only. 9. For push-pull configuration, circuit schematic is shown with actuator in extended position. FIGURE 1. Configuration and dimensions - Continued.Provided by IHSNot for ResaleNo repro
7、duction or networking permitted without license from IHS-,-,-MIL-PRF-8805/3L 3 REQUIREMENTS: Dimensions and configuration: See figure 1. Enclosure design: 2 (dust-tight). Temperature characteristic: 1 (-55C to +85C). Shock type: H for monetary type only (no contact opening or closing in excess of 20
8、 milliseconds). M for other units. Sinusoidal vibration grade: 2 (10 to 2,000 Hz). Weight: .050 pound maximum. Solderability: Applicable to screw tabs and solder lugs. Operating characteristics: Total plunger travel: .085 .015 inch. Operating force: Momentary: 4 1 pounds. Push-pull: 0.5 to 2 pounds.
9、 Releasing force: 1 pound minimum, monetary. Terminal strength torque test: Not applicable. Strength of actuator and stop: 75 pounds for 3 terminals circuitry; 40 pounds for all others. Finish: The switch case shall be corrosion resistant , lusterless black. Dielectric withstanding voltage: Sea leve
10、l: 1,000 V rms. After electrical endurance: 200 V rms. Intermediate current: 1/ MS25089-1, MS25089-2, and MS25089-3: 200,000 cycles. MS25089-4 and MS25089-5: 50, 000 cycles. 1/ Prior to test, units preconditioned at 85C for 48 hours. Provided by IHSNot for ResaleNo reproduction or networking permitt
11、ed without license from IHS-,-,-MIL-PRF-8805/3L 4 Mechanical endurance (10 to 15 cpm): MS25089-1, MS25089-2, and MS25089-3: At room temperature: 200,000 cycles. At -55C and +85C: 100,000 cycles each. MS25089-4 and MS25089-5: 50,000 cycles. Electrical endurance: 25,000 cycles at sea level; 5,000 cycl
12、es at 50,000 feet. Electrical ratings: Central terminal ratings: 3 amperes maximum. Other than center terminals: See table I. TABLE I. Electrical ratings, power circuit switches. 1/ Sea level 50,000 feet Load 28 V dc 115/V ac, 60/400 Hz 28 V dc Amperes Amperes Amperes Resistive- 10 10 - - - Inductiv
13、e - 5 5 5 Lamp - 3 3 - - - 1/ Center terminal rating: 3 amperes maximum. 2/ The 400 Hz ratings are shown for information only and do not require electrical endurance testing. Sand and dust: Applicable. Electrical logic circuit (5.0 V dc, .010 ampere): Applicable when specified (see table II): 25,000
14、 cycles at an actuation rate of 120 cycles per minute maximum with no “stick“, or “misses“, allowed when tested in accordance with EIA RS448, method 17 as follows: Test condition: Each switch contact shall be tested using a 5.0 0.5 V dc, 10 1 mA resistive load. During each closure of the contacts, t
15、he voltage drop across the switch terminals shall be monitored for a duration of no less than 50 percent of each contact static closure. The switch contacts need not be monitored until 10 milliseconds after the initial contact closure to exclude any contact bounce. During each opening of the contact
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DLAMILPRF88053L2009SWITCHESPUSH10AMPERESORLOWLEVELDUSTTIGHTPDF

链接地址:http://www.mydoc123.com/p-693119.html