DIN 51451-2004 Testing of petroleum products and related products - Analysis by infrared spectrometry - General working principles《石油产品及相关产品的检验 红外线光谱分析 一般工作原理》.pdf
《DIN 51451-2004 Testing of petroleum products and related products - Analysis by infrared spectrometry - General working principles《石油产品及相关产品的检验 红外线光谱分析 一般工作原理》.pdf》由会员分享,可在线阅读,更多相关《DIN 51451-2004 Testing of petroleum products and related products - Analysis by infrared spectrometry - General working principles《石油产品及相关产品的检验 红外线光谱分析 一般工作原理》.pdf(18页珍藏版)》请在麦多课文档分享上搜索。
1、September 2004DEUTSCHE NORM English price group 11No part of this translation may be reproduced without prior permission ofDIN Deutsches Institut fr Normung e. V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).ICS 75.080!$Qdl“14665
2、73www.din.deDDIN 51451Testing of petroleum products and related products Analysis by infrared spectrometry General working principlesPrfung von Minerallerzeugnissen und verwandten Produkten Infrarotspektrometrische Analyse Allgemeine ArbeitsgrundlagenSupersedesDIN 51451:1988-09www.beuth.deIn case of
3、 doubt, the German-language original should be consulted as the authoritative text.Translation by DIN-Sprachendienst.Document comprises 18 pagesDIN 51451:2004-09 2 Foreword This standard has been prepared by Technical Committee Moleklspektrometrie of the Fachausschuss Minerall- und Brennstoffnormung
4、 of the Normenausschuss Materialprfung (Materials Testing Standards Committee). Amendments This standard differs from DIN 51451:1988-09 as follows: a) The FT (Fourier-Transform) instruments have been included in addition to the grating instruments (see clause 5 and Annex A). b) Clause 2 “Normative r
5、eferences” has been added. c) Further information relating to instrument checking and alignment has been included. d) A new Figure 2 “Baseline method (linear absorbance ordinate)” has been added. Previous editions DIN 51451: 1988-09 1 Scope This standard specifies the principles governing the use of
6、 infrared (IR) spectrometry for analysing products based on petroleum and synthetic oils, including their additives. This standard covers the standard procedures for qualitatively identifying and for semi-quantitatively and quantitatively determining the contents of individual constituents. The purp
7、ose of the standard is to facilitate the preparation of standards governing the analysis of special groups of substances by IR spectrometry, thereby reducing their individual volumes, and to standardize the associated working procedures as early as possible. 2 Normative references This standard inco
8、rporates, by dated or undated reference, provisions from other publications. These normative references are cited at the appropriate places in the text, and the titles of the publications are listed below. For dated references, subsequent amendments to or revisions of any of these publications apply
9、 to this standard only when incorporated in it by amendment or revision. For undated references, the latest edition of the publication (including amendments) referred to applies. DIN 12491, Vacuum desiccators for laboratory use DIN 32635, Concepts, symbols and units relating to the spectrophotometri
10、c analysis of solutions DIN 50011-11, Artificial climates in technical applications Controlled-atmosphere test installations General concepts and requirements DIN 51451:2004-09 3 DIN 50011-12, Artificial climates in technical applications Air temperature as a climatological quantity in controlled-at
11、mosphere test installations DIN 51820-1, Infrared spectrometric analysis of lubricating greases Recording and evaluation of infrared spectra 3 Principle The attenuation of the infrared radiation in an irradiated sample is recorded as a function of wavelength. The position of the absorption bands and
12、 their magnitude in the spectrum obtained enables the sample to be analysed qualitatively and quantitatively. 4 General 4.1 Theoretical principles On passing through a transparent, homogeneous medium, radiation is attenuated by reflection, scattering and absorption. Neglecting reflection and scatter
13、ing, the absorption is related to the content of an individual absorbing substance in a nonabsorbing solvent and the path length by the Lambert-Beer-Bouguer law (equation 1): dcE = lglgae(1) =ea100% (2) where e, aare the radiant powers of the radiation entering and leaving the sample, respectively;
14、is the net transmittance (also referred to as transmission T), i.e. the ratio of the radiant power atransmitted by the sample to the incident radiant power e, which is often reported as a percentage (see equation (2); E is the absorbance (cf. DIN 32635); NOTE 1 In international usage, the symbol A()
15、 is also used for the absorbance. is the molar absorptivity, in m2/mol, if the concentration is expressed in mol/l and the path length in mm (if other units are used, the molar absorptivity is denoted by and the resultant unit shall then be specified); c is the concentration of the absorbing substan
16、ce, usually in mol/l; d is the path length (the optical distance traversed in the sample), in mm. NOTE 2 The net transmittance, was previously referred to as transmission T. The radiant powers, aand e, were previously referred to as intensities I and I0. DIN 51451:2004-09 4 is often very dependent o
17、n the chosen solvent and can be altered by interactions, for example association, between individual components in the sample under examination. The total absorbance, Etot, at a given wavelength for a multicomponent mixture is the sum of the contributions Ei,of the components i in the mixture as in
18、equation 3: =iicdEE,ii,tot,(3) If the individual molar absorptivities, i, are known, the contents of individual components i or, under favourable circumstances, of all the components i in a mixture can be determined by measuring Etot,at a number of wavelengths . 4.2 Units Wavelength Normally m is us
19、ed for wavelength (1 m = 106m) Wavenumber Normally cm1for wavenumber (1 cm1= 102m1; = 10 000/) Molar concentration c Normally mol/l is used for molar concentration c Proportion by mass w Normally g/100 g (i.e. % (m/m) or mg/kg are used for proportion by mass w Proportion by volume Normally ml/100 ml
20、 (i.e. % (V/V) is used for proportion by volume . NOTE 3 The name and/or the quantity symbol of the physical quantity percentages, e.g. proportion by mass or m/m, shall be stated for percentages specified without naming the units (e.g. g/100 g or ml/100 ml). NOTE 4 Other units, e.g. g/l or g/ml, are
21、 permitted, but the symbol used in the equation shall carry a prime (e.g. ). 5 Apparatus 5.1 IR spectrometer 5.1.1 General In principle, both grating and FT (Fourier-Transform) instruments can be used for petroleum analysis, but FT instruments are generally preferred because of their greater capabil
22、ities. Instruments using prism monochromators are now obsolete. Instruments using filter monochromators are obtainable on the market, but do not figure in this standard since most IR analyses in the petroleum sector require the recording and evaluation of an entire spectral range and not of a single
23、 wavelength. The double-beam instruments used in the past are being increasingly replaced by single-beam instruments in which the optical correction used in the former is replaced by sequential measurement with subsequent correction by calculation. Further information on the design features of moder
24、n spectrometers will be found in Annex A. DIN 51451:2004-09 5 5.1.2 Minimum requirements The specific requirements in a standard, e.g. relating to wavenumber precision, resolution and repeatability, shall be specified, where necessary, in the individual test standards. However, as far as possible, t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DIN514512004TESTINGOFPETROLEUMPRODUCTSANDRELATEDPRODUCTSANALYSISBYINFRAREDSPECTROMETRYGENERALWORKINGPRINCIPLES

链接地址:http://www.mydoc123.com/p-658511.html