1、UDC 62.004.64(084.21) : 62-192 : 621 .O39 : 001.4 : 003.62 DEUTSCHE NORM September 1981 Fehlerbaumanalyse; Methode und Bildzeichen Supersedes DIN 25 42406.77 Fault tree analysis as considered here must be distinguished from the incident sequence analysis (see DIN 25 41 9 Part 1). In the incident seq
2、uence analysis the object is to find the undesired events that result from a particular cause, whilst fault tree analysis starts with the undesired event and the object is then to find all the causes that can lead to this event. Where possible the definitions have been made consistent with those in
3、DIN 40042 (preliminary standard). The graphical symbols used are as far as possible based on DIN 40700 Part 14 and the American IEEE Standard 352-1975 published by the Institute of Electrical and Electronics Engineers *). Contents Page 1 Field of application . 2 2 Purpose . 2 4 Method . 3 3 concepts
4、 2 4.1 Model and graphical symbols 3 4.2 Steps in analysis 4 4.3 Notes on systems analysis 4 4.4 Undesired event and failure criteria 5 4.5 Relevant reliability parameters and time intervals. 5 4.6 Modes of failure of components 5 4.8 Analysis of common mode failures 6 4.9 Notes on evaluating the fa
5、ult tree . 6 Appendix A Example of a fault tree . 7 4.7 Drawing up the fault tree 5 *) Obtainable from Auslandsnormenvermittlung (foreign standardsservice) of DIN Deutsches Institut fr Normung e.V., Burggrafenstrasse 4-1 O, D-I O00 Berlin 30. Continued on pages 2 to 8 iesalerightsof German Stan such
6、 a failure is therefore represented as a standard input. A secondary failure or a controlled failure are not necessarily present in all cases. If they are, step f) follows. Once the particular branch of the tree has been completed, it is necessary to consider the next failure from step c) onwards. I
7、f there are no further failures to develop, the fault tree is complete. The failure is not a failure of a functional element. The description of the failure given in the comments rectangle must be regarded as the undesired event of the fault tree to be developed below it: Step b) then follows. COPYR
8、IGHT DIN DEUTSCHES Institut Fur Normung E.V.- EnglishLicensed by Information Handling ServicesPage 6 DIN 25424 Part 1 a) Undesired event I I 7 I b. c. d) Secondary Controlled failure failure Failure 0 Functional element Failure A Failure B Secondary flp$i?-l o (3 Figure 1. Example of procedure for d
9、rawing up a fault tree Note: At the broken lines the fault tree has been left without tracing any further branches. The letters along the left hand edge of the figure show the steps in the analysis in accordance with sub- clause 4.7. 4.9 Notes on evaluating the fault tree The main results obtained f
10、rom fault tree analysis are: a) systematic determination of combinations of failures that result in the undesired event, IA I Figure 2. Example showing representation of common mode failures b) the frequency of occurrence of these combinations c) the frequency of occurrence of the undesired event, d
11、) the least combination of failures that result in the undesired event. At this point it is useful to draw attention to the effect of common mode failures (see subclause 4.8). Both analytic methods and simulation methods (Monte Carlo method) are available for systematic evaluation of a fault tree. A
12、nalytical methods for example consist of modifying the system structure given by the fault tree so that it is possible to evaluate it on the basis of a probability calculation. Fault trees containing only NOT, OR or AND logic functions can in many cases be evaluated with a simple computing procedure
13、 (a standard is being pre- pared giving examples of these). Simulation methods consist of simulating the time behaviour of the fault tree inputs by the use of random numbers. These methods are particularly useful for assessing the operational and fault behaviour of a technical system over a period o
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DIN2542411981FAULTTREEANALYSISMETHODANDGRAPHICALSYMBOLS 失效 分析 方法 图形 符号 PDF

链接地址:http://www.mydoc123.com/p-655346.html