DIN 10972-2003 Sensory analysis - A - not A test《感官分析 A和非A试验》.pdf
《DIN 10972-2003 Sensory analysis - A - not A test《感官分析 A和非A试验》.pdf》由会员分享,可在线阅读,更多相关《DIN 10972-2003 Sensory analysis - A - not A test《感官分析 A和非A试验》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、ICS 67.240Sensorische Prfverfahren ,A“ ,nicht-A“ PrfungIn keeping with current practice in standards published by the International Organization for Standardization(ISO), a comma has been used throughout as the decimal marker.Ref. No. DIN 10972 : 2003-08English price group 10 Sales No. 011009.04DEUT
2、SCHE NORM August 2003 No part of this translation may be reproduced without the prior permission ofDIN Deutsches Institut fr Normung e.V., Berlin. Beuth Verlag GmbH, 10772 Berlin, Germany,has the exclusive right of sale for German Standards (DIN-Normen).Translation by DIN-Sprachendienst.In case of d
3、oubt, the German-language original should be consulted as the authoritative text.Sensory analysisA or not A testContinued on pages 2 to 8.10972ForewordThis standard has been prepared by Technical Committee Sensorik of the Normenausschuss Lebensmittelund landwirtschaftliche Produkte (Foodstuffs and A
4、gricultural Products Standards Committee). It is equiva-lent to International Standard ISO 8588, but differs in thata) the two different not A test samples provided in the ISO 8588 procedure for exceptional cases havenot been included because the test situations are seldom encountered in practice an
5、d the statisticalevaluation was considered to be too cumbersome,b) it contains a note that the method is unsuitable for equivalence tests, which is important, in particular,if incorrect use of the present standard is to be avoided.ContentsPageForeword . . . . . . . . . . . . . . . . . . . . . . . .
6、. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 Normative references . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23 Conc
7、epts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24 Principle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25 Sampling . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8、. . . . . . . . . . . . . . . . . . . . . . . . . 26 Assessors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Test room and test equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38 Preparation of test portions .
9、 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39 Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 310 Evaluation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
10、 . . . 411 Test report . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5Appendix A Critical values for test statistics . . . . . . . . . . . . . . . . . . . . . . . . . 5Appendix B Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11、. . . . . . . . . . . . . . . 5Appendix C Specimen response forms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7Page 2DIN 10972 : 2003-081 ScopeThis standard specifies a method of detecting a difference between two test samples and, in particular, maybe used as:a) a difference test fo
12、r test samples whose attributes are subject to variation;b) a recognition test for determining whether assessors are able to detect the deviation of an attribute froma known attribute in a test sample;c) a test for recognizing new attributes in addition to those already known;d) a perception test fo
13、r determining the sensitivity of an assessor to a particular attribute.This method is not suitable for equivalence tests.2 Normative referencesThis standard incorporates, by dated or undated reference, provisions from other publications. These norma-tive references are cited at the appropriate place
14、s in the text, and the titles of the publications are listed below.For dated references, subsequent amendments to or revisions of any of these publications apply to thisstandard only when incorporated in it by amendment or revision. For undated references, the latest edition ofthe publication referr
15、ed to applies.DIN 10950-1 Sensory analysis ConceptsDIN 10956 Equipment for sensory analysis Universal testing glasses and lids Requirements andinstructions for useDIN 10960 Equipment for sensory analysis Wine-tasting glassesDIN 10962 Areas for sensory analysis Specification of test roomsISO 5492 : 1
16、992 Sensory analysis VocabularyISO 8588 : 1987 Sensory analysis Methodology “A” “not A” test1 Fisher, R. A., Statistical methods for research workers, Edinburgh: Oliver b) test portion size;c) number of test portions;d) temperature of test portions;e) masking of individual attributes.The test portio
17、ns shall be served in the form in which they are normally consumed. The assessor shall not beable to draw any conclusions about the origin of the sample from the manner of presentation and the testportions shall be served in an identical way.8.3 Test portion codingThe test portions shall preferably
18、be coded using three-figure random numbers and shall be re-coded beforeevery test.9 ProcedureThe A or not A test assumes an explicit familiarization with test sample A and, after testing has started, theassessor will no longer have access to test sample A.The order in which the A and not A test port
19、ions are served shall be random and different for every assessor,each of whom shall receive the same number of A and not A test portions, but it is not necessary for thenumber of A and not A test portions to be the same.The actual number of A and not A test portions shall not be disclosed to the ass
20、essors.The assessors shall taste the test portions one after the other in the order served and decide whether each testportion is A or not A.Depending on the objective of the test, the method may be varied as follows:a) the initial familiarization may cover not only A test portions, but also not A t
21、est portions;b) the A test portion may be freely available throughout the test.The time interval between serving the test portions will depend on their nature, but shall be constant to avoidinterfering effects due to sensory adaptation.Page 4DIN 10972 : 2003-0810 EvaluationThe results shall be evalu
22、ated by summarizing the correct and incorrect assignments of A and not A testportions in a table (see table 1).Table 1: Summary of resultsTest portion servedTotalA not AAssessorsA n11n12n1.identificationnot A n21n22n2.Total n.1n.2nwherea) n11and n22are the numbers of correct A and not A responses, r
23、espectively;b) n21and n12are the numbers of incorrect A and not A responses, respectively;c) n1.and n2.are the sums of the correct responses in the A and not A rows, respectively;d) n.1and n.2are the sums of the correct A column and not A column responses, respectively;e) nis the sum of all the resp
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- DIN109722003SENSORYANALYSISANOTATEST 感官 分析 试验 PDF

链接地址:http://www.mydoc123.com/p-652554.html