BS ISO 11599-1998 Determination of gas porosity and gas permeability of hydraulic binders containing embedded radioactive waste《含有包埋放射废物的液压粘合剂气孔和透气性的测定》.pdf
《BS ISO 11599-1998 Determination of gas porosity and gas permeability of hydraulic binders containing embedded radioactive waste《含有包埋放射废物的液压粘合剂气孔和透气性的测定》.pdf》由会员分享,可在线阅读,更多相关《BS ISO 11599-1998 Determination of gas porosity and gas permeability of hydraulic binders containing embedded radioactive waste《含有包埋放射废物的液压粘合剂气孔和透气性的测定》.pdf(24页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS ISO 11599:1997 Determination of gas porosity and gas permeability of hydraulic binders containing embedded radioactive waste ICS 13.030.30; 13.030.40; 27.120.20BSISO 11599:1997 This British Standard, having been prepared under the directionof the Engineering SectorBoard, was publ
2、ished underthe authority of the Standards Board and comes intoeffect on 15 June 1998 BSI 04-1999 ISBN 0 580 29925 2 National foreword This British Standard reproduces verbatim ISO115991997 and implements it as the UK national standard. The UK participation in its preparation was entrusted to Technic
3、al Committee NCE/9, Nuclear fuel technology, which has the responsibility to: aid enquirers to understand the text; present to the responsible international/European committee any enquiries on the interpretation, or proposals for change, and keep the UK interests informed; monitor related internatio
4、nal and European developments and promulgate them in the UK. A list of organizations represented on this committee can be obtained on request to its secretary. Cross-references The British Standards which implement international or European publications referred to in this document may be found in t
5、he BSI Standards Catalogue under the section entitled “International Standards Correspondence Index”, or by using the “Find” facility of the BSI Standards Electronic Catalogue. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are r
6、esponsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, theISO title page, pages ii to iv, pages 1 to 15 and a back cover. Th
7、is standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. Amendments issued since publication Amd. No. Date CommentsBSISO 11599:1997 BSI 04-1999 i Contents Page National foreword Inside front c
8、over Foreword iii Text of ISO 11599 1ii blankBSISO 11599:1997 ii BSI 04-1999 Contents Page Foreword iii 1 Scope 1 2 Sample preparation 1 3 Measurement of open gas porosity 5 4 Measurement of gas permeability 8 Annex A (normative) Gas pycnometer 12 Annex B (informative) Bibliography 15 Figure 1 Level
9、ling of moulded sample 2 Figure 2 Sampling of homogeneous waste forms 3 Figure 3 Sampling of heterogeneous waste forms of block volume # 2m 3 4 Figure 4 Sampling of heterogeneous waste forms of block volume 2m 3 5 Figure 5 Gas pycnometer 7 Figure 6 Gas permeameter 10BSISO 11599:1997 BSI 04-1999 iii
10、Foreword ISO (the International Organization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a t
11、echnical committee has been established has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters
12、 of electrotechnical standardization. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Publication as an International Standard requires approval by at least 75 % of the member bodies casting a vote. International Standard ISO 11599 wa
13、s prepared by Technical Committee ISO/TC85, Nuclear energy, Subcommittee SC5, Nuclear fuel technology. Annex A forms an integral part of this International Standard. Annex B is for information only.iv blankBSISO 11599:1997 BSI 04-1999 1 Introduction Hydraulic binder-based matrices can be hardened pu
14、re cement, mortar or concrete containing embedded wastes; these wastes can be radioactive or non-radioactive. It has been observed that the durability of these matrices, as well as the leaching rate of immobilized radionuclides in water are very largely dependent on gas open porosity and gas permeab
15、ility of the matrix. Also, permeability and open porosity can be related to the homogeneity of a hydraulic binder matrix. The objective of this International Standard is to offer a methodology that allows rapid estimation of the gas porosity and permeability of hydraulic binders. A direct comparison
16、 of the results obtained in different laboratories would thus be possible by checking the quality or ageing behaviour of a waste form. The International Standard, once implemented, would reduce discrepancies between laboratories. 1 Scope This International Standard describes the principles and metho
17、dologies of measuring both gas open porosity and permeability of hydraulic binder-based matrices used for immobilization of radioactive waste. The measurements can be carried out by using different apparatus designed and constructed on the basis of a few recommended characteristics. The measurements
18、 can be performed on samples prepared in a laboratory or taken from industrial production. Samples can be obtained by moulding or by coring a block. 2 Sample preparation The samples may be obtained either by moulding or by coring of a block. The choice shall be made according to the purpose of the s
19、tudy. 2.1 Moulded samples The samples are moulded when the hardened cement, mortar or concrete has been prepared either in the laboratory or taken from an industrial or pilot plant. 2.1.1 Sample size The sample shall be an orthogonal cylinder with square cross-section, or a rectangular parallelepipe
20、d. The acceptable sample length is in the range between (40 2) mm and (220 5) mm. The recommended length is (110 3) mm. The end orthogonalities in relation to the generating line direction shall be (90 1) . Straight section inherent flatness shall be 0,5mm. 2.1.2 Mould The sample is poured into moul
21、ds made of steel, plastic or cardboard with an inner sulfurized paper lining. Mould design shall allow withdrawal of the pattern from the mould without knocking flakes off the solid angle of intersection of the two surfaces. During mould filling, the mixture is stirred with a straight rod to elimina
22、te possible air bubbles. If drum vibration is arranged for an industrial process, the sample is compressed with a vibrating microtable. Levelling of the upper surface of the sample is carried out with a steel strip. The cross-section of the strip shall be trapezoidal with a 45 angle. The dimensions
23、of the strip shall be as follows: length: 450mm; width of the major base: 60mm; thickness: 15mm. In a first step, levelling enables a raw surface of a sample to be obtained using the strips chamfered edge (seeoperation A in Figure 1). In a second step, use the strips shorter base to obtain the final
24、 surface of the sample to be used (seeoperation B in Figure 1).BSISO 11599:1997 2 BSI 04-1999 Raw and final levellings are made with a sawing movement (an alternating movement). For each levelling, two passes are made with a change in direction of 90 . During levelling, cavities are filled with the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO115991998DETERMINATIONOFGASPOROSITYANDGASPERMEABILITYOFHYDRAULICBINDERSCONTAININGEMBEDDEDRADIOACTIVEWASTE

链接地址:http://www.mydoc123.com/p-583618.html