BS ISO 10770-2-2012 Hydraulic fluid power Electrically modulated hydraulic control valves Test methods for three-port directional flow-control valves《液压流体动力 电动调节液压控制阀 三向流量控制阀的试验方法》.pdf
《BS ISO 10770-2-2012 Hydraulic fluid power Electrically modulated hydraulic control valves Test methods for three-port directional flow-control valves《液压流体动力 电动调节液压控制阀 三向流量控制阀的试验方法》.pdf》由会员分享,可在线阅读,更多相关《BS ISO 10770-2-2012 Hydraulic fluid power Electrically modulated hydraulic control valves Test methods for three-port directional flow-control valves《液压流体动力 电动调节液压控制阀 三向流量控制阀的试验方法》.pdf(42页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationBS ISO 10770-2:2012Hydraulic fluid power Electrically modulatedhydraulic control valvesPart 2: Test methods for three-portdirectional flow-control valvesBS ISO 10770-2:2012 BRITI
2、SH STANDARDNational forewordThis British Standard is the UK implementation of ISO 10770-2:2012.It supersedes BS ISO 10770-2:1998 which is withdrawn.The UK participation in its preparation was entrusted to TechnicalCommittee MCE/18/-/8, Product testing.A list of organizations represented on this comm
3、ittee can beobtained on request to its secretary.This publication does not purport to include all the necessaryprovisions of a contract. Users are responsible for its correctapplication. The British Standards Institution 2012. Published by BSI StandardsLimited 2012ISBN 978 0 580 74182 1ICS 23.100.50
4、Compliance with a British Standard cannot confer immunity fromlegal obligations.This British Standard was published under the authority of theStandards Policy and Strategy Committee on 31 December 2012.Amendments issued since publicationDate Text affectedBS ISO 10770-2:2012 ISO 2012Hydraulic fluid p
5、ower Electrically modulated hydraulic control valves Part 2: Test methods for three-port directional flow-control valvesTransmissions hydrauliques Distributeurs hydrauliques modulation lectrique Partie 2: Mthodes dessai pour distributeurs de commande de dbit trois voiesINTERNATIONAL STANDARDISO10770
6、-2Second edition2012-12-01Reference numberISO 10770-2:2012(E)BS ISO 10770-2:2012ISO 10770-2:2012(E)ii ISO 2012 All rights reservedCOPYRIGHT PROTECTED DOCUMENT ISO 2012All rights reserved. Unless otherwise specified, no part of this publication may be reproduced or utilized in any form or by any mean
7、s, electronic or mechanical, including photocopying and microfilm, without permission in writing from either ISO at the address below or ISOs member body in the country of the requester.ISO copyright officeCase postale 56 CH-1211 Geneva 20Tel. + 41 22 749 01 11Fax + 41 22 749 09 47E-mail copyrightis
8、o.orgWeb www.iso.orgPublished in SwitzerlandBS ISO 10770-2:2012ISO 10770-2:2012(E) ISO 2012 All rights reserved iiiContents PageForeword ivIntroduction v1 Scope 12 Normative references . 13 Terms, definitions, symbols and units 13.1 Terms and definitions . 13.2 Symbols and units 24 Standard test con
9、ditions . 35 Test installation 36 Accuracy 56.1 Instrument accuracy . 56.2 Dynamic range . 57 Electrical tests for valves without integrated electronics 57.1 General . 57.2 Coil resistance . 57.3 Coil inductance - Optional test 57.4 Insulation resistance 78 Performance tests . 78.1 Steady-state test
10、s 78.2 Dynamic tests .219 Pressure impulse test 2810 Presentation of results .2810.1 General .2810.2 Test reports .2911 Identification statement (reference to this part of ISO 10770) 30Annex A (informative) Testing guidance .31BS ISO 10770-2:2012ISO 10770-2:2012(E)ForewordISO (the International Orga
11、nization for Standardization) is a worldwide federation of national standards bodies (ISO member bodies). The work of preparing International Standards is normally carried out through ISO technical committees. Each member body interested in a subject for which a technical committee has been establis
12、hed has the right to be represented on that committee. International organizations, governmental and non-governmental, in liaison with ISO, also take part in the work. ISO collaborates closely with the International Electrotechnical Commission (IEC) on all matters of electrotechnical standardization
13、.International Standards are drafted in accordance with the rules given in the ISO/IEC Directives, Part 2.The main task of technical committees is to prepare International Standards. Draft International Standards adopted by the technical committees are circulated to the member bodies for voting. Pub
14、lication as an International Standard requires approval by at least 75 % of the member bodies casting a vote.Attention is drawn to the possibility that some of the elements of this document may be the subject of patent rights. ISO shall not be held responsible for identifying any or all such patent
15、rights.ISO 10770-2 was prepared by Technical Committee ISO/TC 131, Fluid power systems, Subcommittee SC 8, Product testing.This second edition cancels and replaces the first edition (ISO 10770-2:1998) which has been technically revised.ISO 10770 consists of the following parts, under the general tit
16、le Hydraulic fluid power Electrically modulated hydraulic control valves: Part 1: Test methods for four-port directional flow-control valves Part 2: Test methods for three-port directional flow-control valves Part 3: Test methods for pressure control valvesiv ISO 2012 All rights reservedBS ISO 10770
17、-2:2012ISO 10770-2:2012(E)IntroductionThis part of ISO 10770 has been prepared with the intention of improving the uniformity of valve testing and hence the consistency of recorded valve performance data so that this data can be used for system design, regardless of the data source. ISO 2012 All rig
18、hts reserved vBS ISO 10770-2:2012BS ISO 10770-2:2012Hydraulic fluid power Electrically modulated hydraulic control valves Part 2: Test methods for three-port directional flow-control valves1 ScopeThis part of ISO 10770 describes methods for determining the performance characteristics of electrically
19、 modulated hydraulic three-port directional flow-control valves.This type of electrohydraulic valve controls the direction and amount of hydraulic flow in a hydraulic system.2 Normative referencesThe following referenced documents are indispensable for the application of this document. For dated ref
20、erences, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.ISO 1219-1, Fluid power systems and components Graphical symbols and circuit diagrams Part 1: Graphical symbols for conventional use and data-processing a
21、pplicationsISO 3448, Industrial liquid lubricants ISO viscosity classificationISO 4406, Hydraulic fluid power Fluids Method for coding the level of contamination by solid particlesISO 5598, Fluid power systems and components VocabularyISO 6743-4, Lubricants, industrial oils and related products (cla
22、ss L) Classification Part 4: Family H (Hydraulic systems)ISO 9110-1:1990, Hydraulic fluid power Measurement techniques Part 1: General measurement principlesISO 10771-1, Hydraulic fluid power Fatigue pressure testing of metal pressure-containing envelopes Part 1: Test methodIEC 60617-DB-12M, Graphic
23、al symbols for diagrams3 Terms, definitions, symbols and units3.1 Terms and definitionsFor the purposes of this document, the terms and definitions given in ISO 5598 and the following apply.3.1.1electrically modulated hydraulic directional flow control valvevalve that provides a degree of proportion
24、al flow control in response to a continuously variable electrical input signalNOTE The flow direction can be changed by the input signal.3.1.2input signal deadbandportion of input signal that does not produce a controlled flowINTERNATIONAL STANDARD ISO 10770-2:2012(E) ISO 2012 All rights reserved 1B
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSISO1077022012HYDRAULICFLUIDPOWERELECTRICALLYMODULATEDHYDRAULICCONTROLVALVESTESTMETHODSFORTHREEPORTDIRECTIONALFLOWCONTROLVALVES

链接地址:http://www.mydoc123.com/p-583336.html