《BS EN 60534-8-2-2011 Industrial-process control valves Noise considerations Laboratory measurement of noise generated by hydrodynamic flow through control valves《工业过程控制阀 流动液流经控制阀产生.pdf》由会员分享,可在线阅读,更多相关《BS EN 60534-8-2-2011 Industrial-process control valves Noise considerations Laboratory measurement of noise generated by hydrodynamic flow through control valves《工业过程控制阀 流动液流经控制阀产生.pdf(26页珍藏版)》请在麦多课文档分享上搜索。
1、raising standards worldwideNO COPYING WITHOUT BSI PERMISSION EXCEPT AS PERMITTED BY COPYRIGHT LAWBSI Standards PublicationIndustrial-process control valvesPart 8-2: Noise considerations Laboratory measurement of noise generated by hydrodynamic flow through control valvesBS EN 60534-8-2:2011Copyright
2、 European Committee for Electrotechnical Standardization Provided by IHS under license with CENELECNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-National forewordThis British Standard is the UK implementation of EN 60534-8-2:2011. It is identical to IEC 60534-8-2
3、:2011. It supersedes BS EN 60534-8-2:1993, which will be withdrawn on 16 November 2014.The UK participation in its preparation was entrusted by Technical Committee GEL/65, Measurement and control, to Subcommittee GEL/65/2, Elements of systems.A list of organizations represented on this committee can
4、 be obtained on request to its secretary.This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. The British Standards Institution 2012Published by BSI Standards Limited 2012 ISBN 978 0 580 76471 4 ICS 17.140.20; 23.
5、060.40; 25.040.40 Compliance with a British Standard cannot confer immunity from legal obligations.This British Standard was published under the authority of the Stand-ards Policy and Strategy Committee on 31 August 2012.Amendments issued since publicationDate Text affectedBRITISH STANDARDBS EN 6053
6、4-8-2:2011Copyright European Committee for Electrotechnical Standardization Provided by IHS under license with CENELECNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-EUROPEAN STANDARD EN 60534-8-2 NORME EUROPENNE EUROPISCHE NORM December 2011 CENELEC European Commi
7、ttee for Electrotechnical Standardization Comit Europen de Normalisation Electrotechnique Europisches Komitee fr Elektrotechnische Normung Management Centre: Avenue Marnix 17, B - 1000 Brussels 2011 CENELEC - All rights of exploitation in any form and by any means reserved worldwide for CENELEC memb
8、ers. Ref. No. EN 60534-8-2:2011 E ICS 17.140.20; 23.060.40; 25.040.40 Supersedes EN 60534-8-2:1993English version Industrial-process control valves - Part 8-2: Noise considerations - Laboratory measurement of noise generated by hydrodynamic flow through control valves (IEC 60534-8-2:2011) Vannes de
9、rgulation des processus industriels - Partie 8-2: Considrations sur le bruit - Mesure en laboratoire du bruit cr par un coulement hydrodynamique dans une vanne de rgulation (CEI 60534-8-2:2011) Stellventile fr die Prozeregelung - Teil 8-2: Geruschemission - Laboratoriumsmessungen von Geruschen bei f
10、lssigkeitsdurchstrmten Stellventilen (IEC 60534-8-2:2011) This European Standard was approved by CENELEC on 2011-11-16. CENELEC members are bound to comply with the CEN/CENELEC Internal Regulations which stipulate the conditions for giving this European Standard the status of a national standard wit
11、hout any alteration. Up-to-date lists and bibliographical references concerning such national standards may be obtained on application to the CEN-CENELEC Management Centre or to any CENELEC member. This European Standard exists in three official versions (English, French, German). A version in any o
12、ther language made by translation under the responsibility of a CENELEC member into its own language and notified to the CEN-CENELEC Management Centre has the same status as the official versions. CENELEC members are the national electrotechnical committees of Austria, Belgium, Bulgaria, Croatia, Cy
13、prus, the Czech Republic, Denmark, Estonia, Finland, France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latvia, Lithuania, Luxembourg, Malta, the Netherlands, Norway, Poland, Portugal, Romania, Slovakia, Slovenia, Spain, Sweden, Switzerland and the United Kingdom. BS EN 60534-8-2:2011Copyrig
14、ht European Committee for Electrotechnical Standardization Provided by IHS under license with CENELECNot for ResaleNo reproduction or networking permitted without license from IHS-,-,-EN 60534-8-2:2011 - 2 - Foreword The text of document 65B/801/FDIS, future edition 2 of IEC 60534-8-2, prepared by S
15、C 65B, “Devices b) decrease the pressure ratio xFin such a way that there is a transition from cavitating to non-cavitating flow and measure Lpas a function of frequency for each value of xFused; c) from the data obtained in b), determine the approximate frequency which gives the maximum Lpresponse.
16、 This is the peak frequency; d) using a sound level meter with an octave band filter that includes the peak frequency, measure the Lpas xFis decreased. The range of xFshall be sufficient to establish the curves in both the cavitating and non-cavitating regions; e) in both the cavitating and non-cavi
17、tating regions, fit a straight line through the data points. The intersection of the straight lines shall determine the value of xFz. See point A in Figure 5; f) repeat the procedure for the other relative flow coefficients given in Clause 8. 8.3.2 A-weighted method This method of determining xFzreq
18、uires the measurement of the overall sound pressure level (LpA) using the A-weighted method. The procedure is as follows (refer to Figure 6): a) at a given travel (corresponding to one of the relative flow coefficients given in Clause 8), the LpAversus xFcurve as shown by the dashed line shall be de
19、termined. Decrease the pressure ratio xFin such a way that there is a transition from cavitating to non-cavitating flow and measure LpAfor each value of xFused; b) from the above curve, xF3and xF6, which are the approximate values at which the LpAcurve changes slope, shall be determined; c) the rang
20、es xFIand xFIIshall each be divided into three equal parts (designated as “a“ and “b“, respectively); d) at each of the values xF6through xF1, the A-weighted overall sound pressure level shall be measured. This procedure shall be repeated twice so that there are three series of measurements; e) for
21、each value of xF, the arithmetic average, pAL , of the three LpAvalues shall be calculated and the points plotted; BS EN 60534-8-2:2011Copyright European Committee for Electrotechnical Standardization Provided by IHS under license with CENELECNot for ResaleNo reproduction or networking permitted wit
22、hout license from IHS-,-,- 14 60534-8-2 IEC:2011 f) using the values of pAL at xF1through xF6, the curves designated as lines 1 and 2 shall be determined by linear regression; g) the point at which lines 1 and 2 intersect shall be determined. The value of xFat this point is xFz; h) repeat the proced
23、ure for the other relative flow coefficients given in Clause 8. T P P PC F TC 9b 9 14 11 12 15 10 13 8 1 2 3 4 4b 5 6 5 7 IEC 2131/11 NOTES System components 1 See Figure 2a or 2b for placement of item 8 (acoustic environment) and item 10 (microphone) 2 Items 8, 12 and 15 are optional 1 = pump 2 = f
24、low measuring device 3 = upstream throttling valve 4 = temperature measuring device 4b = upstream in-line silencer (if necessary) 5 = pressure measuring device 6 = test specimen 7 = test section piping 8 = acoustic environment (test chamber) (Notes 1 and 2) 9 = downstream throttling valve 9b = downs
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BSEN60534822011INDUSTRIALPROCESSCONTROLVALVESNOISECONSIDERATIONSLABORATORYMEASUREMENTOFNOISEGENERATEDBYHYDRODYNAMICFLOWTHROUGHCONTROLVALVES

链接地址:http://www.mydoc123.com/p-575898.html