BS 9251-2014 Fire sprinkler systems for domestic and residential occupancies Code of practice《家用和居住用房的消防喷淋系统 实施规程》.pdf
《BS 9251-2014 Fire sprinkler systems for domestic and residential occupancies Code of practice《家用和居住用房的消防喷淋系统 实施规程》.pdf》由会员分享,可在线阅读,更多相关《BS 9251-2014 Fire sprinkler systems for domestic and residential occupancies Code of practice《家用和居住用房的消防喷淋系统 实施规程》.pdf(46页珍藏版)》请在麦多课文档分享上搜索。
1、BSI Standards PublicationBS 9251:2014Fire sprinkler systems fordomestic and residentialoccupancies Code ofpracticePublishing and copyright informationThe BSI copyright notice displayed in this document indicates when the documentwas last issued. The British Standards Institution 2014Published by BSI
2、 Standards Limited 2014ISBN 978 0 580 82422 7ICS 13.220.20The following BSI references relate to the work on this document:Committee reference FSH/18/2Draft for comment 14/30280481 DCPublication historyFirst published as DD 251, April 2000First edition as BS 9251, January 2005Second (present) editio
3、n, October 2014Amendments issued since publicationDate Text affectedBS 9251:2014 BRITISH STANDARDContentsForeword iiIntroduction 11 Scope 12 Normative references 23 Terms and definitions 24 Preliminary work and consultation 55 Design 86 Installation, commissioning and documentation 207 Maintenance 2
4、3AnnexesAnnex A (informative) Elements of a typical residential sprinkler system 25Annex B (informative) Sprinkler performance, reliability and resilience forsystems installed in the homes of vulnerable people 26Annex C (normative) Hydraulic calculations 27Annex D (normative) Pipework support 33Anne
5、x E (informative) Hydraulic test 33Annex F (informative) Example of system data label 35Bibliography 36List of figuresFigure 1 Stored water supply 14Figure A.1 Elements of a typical mains-fed sprinkler system 25Figure A.2 Elements of a typical pump and tank sprinkler system 25Figure C.1 Example of a
6、 square law graduation graph 32Figure C.2 Blank template of a square law graduation graph 32Figure E.1 Test rig for hydraulic test 34Figure F.1 Example of system data label 35List of tablesTable 1 Category of system 7Table 2 Minimum design parameters 9Table C.1 C values for various type of pipes 29T
7、able C.2a K values for carbon steel tube conforming to BS EN 10255,Medium series 29Table C.2b K values for CPVC conforming to ASTM F442 29Table C.2c K values for copper tube conforming to BS EN 1057:2006+A1,half-hard, R250 designation 29Table C.3a Typical equivalent lengths for steel fittings and va
8、lves 30Table C.3b Typical equivalent lengths for CPVC fittings and valves 30Table C.3c Typical equivalent lengths for copper fittings and valves 31Table D.1 Maximum spacing of fixings for copper and stainless steelpipework 33Table D.2 Maximum spacing of fixings for steel pipework 33Table D.3 Maximum
9、 spacing of fixings for CPVC pipework 33Summary of pagesThis document comprises a front cover, an inside front cover, pages i to iv,pages 1 to 38, an inside back cover and a back cover.BRITISH STANDARD BS 9251:2014 The British Standards Institution 2014 iForewordPublishing informationThis British St
10、andard is published by BSI Standards Limited, under licence fromThe British Standards Institution, and came into effect on 31 October 2014.It was prepared by Subcommittee FSH/18/2, Sprinkler systems, under theauthority of Technical Committee FSH/18, Fixed fire fighting systems. A list oforganization
11、s represented on this committee can be obtained on request to itssecretary.SupersessionThis British Standard supersedes BS 9251:2005, which is withdrawn.Relationship with other publicationsAttention is drawn to the requirements of BS EN 806, with particular regard tobackflow prevention, to BS EN 805
12、 where appropriate, and to BS 1710 forguidance on identification and marking of pipework.Sprinkler protection for industrial premises and commercial buildings other thanthose listed in this standard is specified in BS EN 12845. Where sprinklers are notinstalled primarily for life protection in domes
13、tic and residential occupancies,sprinkler installations conforming to BS EN 12845 might be more appropriatethan those conforming to BS 9251.Guidance on the application of sprinkler systems is given in BS 9991, BS 9999,the Building Regulations 2010, Approved Document B for use in England 1, 2,Wales 3
14、, 4 and its equivalents in Scotland 5 and Northern Ireland 6.Information about this documentThis is a full revision of the standard, and introduces the following principalchanges: introduction of building categorization based on occupancy risk; change of building height limit; variation in sprinkler
15、 head design density; increase in sprinkler head spacing; expanded guidance on preliminary work and consultation; expanded guidance on water supplies; additional measures for vulnerable people and multi-occupancy premises.This British Standard is intended for the use of designers, engineers, archite
16、cts,surveyors, contractors, installers and authorities having jurisdiction.Product certification/inspection/testing. Users of this British Standard are advisedto consider the desirability of third-party certification/inspection/testing ofsystem conformity with this British Standard. Appropriate conf
17、ormity attestationarrangements are described in BS EN ISO 9001. Users seeking assistance inidentifying appropriate conformity assessment bodies or schemes may ask BSI toforward their enquiries to the relevant association.Fire sprinkler systems for domestic and residential applications are designed a
18、ndinstalled as a measure in the protection of life in the event of fire. This BritishStandard presumes that the sprinkler protection will form part of an integratedfire safety system as part of the building design.BRITISH STANDARDBS 9251:2014ii The British Standards Institution 2014The recommendatio
19、ns contained in this British Standard result from the besttechnical information available to the committee at the time of writing.Firefighting and life protection encompasses a wide field of endeavour and assuch it is impracticable to cover every possible factor or circumstance that mightaffect impl
20、ementation of this British Standard.Use of this documentAs a code of practice, this British Standard takes the form of guidance andrecommendations. It should not be quoted as if it were a specification andparticular care should be taken to ensure that claims of compliance are notmisleading.Any user
21、claiming compliance with this British Standard is expected to be able tojustify any course of action that deviates from its recommendations.It has been assumed in the preparation of this British Standard that theexecution of its provisions will be entrusted to appropriately qualified andexperienced
22、people, for whose use it has been produced.Presentational conventionsThe provisions of this standard are presented in roman (i.e. upright) type.Its recommendations are expressed in sentences in which the principal auxiliaryverb is “should”.Commentary, explanation and general informative material is
23、presented insmaller italic type, and does not constitute a normative element.Contractual and legal considerationsThis publication does not purport to include all the necessary provisions of acontract. Users are responsible for its correct application.Compliance with a British Standard cannot confer
24、immunity from legalobligations.Particular attention is drawn to the Water Supply (Water Fittings)Regulations 1999 7, the Water Supply (Water Fittings) (Scotland)Byelaws 2014 8 and the Water Regulations (Northern Ireland) 2006 9in respect of requirements for any fire sprinkler system which conveys, o
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS92512014FIRESPRINKLERSYSTEMSFORDOMESTICANDRESIDENTIALOCCUPANCIESCODEOFPRACTICE 家用 居住 用房 消防 喷淋 系统 实施

链接地址:http://www.mydoc123.com/p-547636.html