《BS 845-2-1987 Methods for assessing thermal performance of boilers for steam hot water and high temperature heat transfer fluids - Comprehensive procedure《蒸汽 热水和高温传热流体用锅炉热性能的估算方法 综.pdf》由会员分享,可在线阅读,更多相关《BS 845-2-1987 Methods for assessing thermal performance of boilers for steam hot water and high temperature heat transfer fluids - Comprehensive procedure《蒸汽 热水和高温传热流体用锅炉热性能的估算方法 综.pdf(50页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS845-2:1987 Methods for Assessing thermal performance of boilers for steam, hot water and high temperature heat transfer fluids Part 2: Comprehensive procedure UDC 621.18.018BS845-2:1987 This British Standard, having been prepared under the directionof the Refrigeration,Heating and
2、 AirConditioning Standards Committee, was published underthe authority of the BoardofBSI and comes into effecton 30 June1987 BSI 11-1999 First published as BS845 April1939 First revision as BS845 September1961 Second revision as BS845 July1972 Third revision as BS845-2 June1987 The following BSI ref
3、erences relate to the work on this standard: Committee reference RHE/10 Draft for comment83/73795DC ISBN 0 580 15857 8 Committees responsible for this British Standard The preparation of this British Standard was entrusted by the Refrigeration, Heating and Air Conditioning Standards Committee (RHE/-
4、) to Technical Committee RHE/10, upon which the following bodies were represented: Associated Offices Technical Committee Association of British Solid Fuel Appliances Manufacturers Association of Shell Boilermakers Boiler and Radiator Manufacturers Association Ltd. British Coal British Combustion Eq
5、uipment Manufacturers Association British Foundry Association British Gas plc Building Services Research and Information Association Chartered Institution of Building Services Engineers Department of Energy (Energy Efficiency Office) Department of Energy (Gas Standards) Department of the Environment
6、 (Property Services Agency) Domestic Solid Fuel Appliances Approval Scheme Engineering Equipment and Materials Users Association Health and Safety Executive Hevac Association Institute of Domestic Heating Engineers Society of British Gas Industries The following bodies were also represented in the d
7、rafting of the standard, through sub-committees and panels: Association of Consulting Engineers British Paper and Board Industry Federation (PIF) Institution of Chemical Engineers Institution of Mechanical Engineers National Industrial Fuel Efficiency Service Water-tube Boilermakers Association Amen
8、dments issued since publication Amd. No. Date of issue CommentsBS845-2:1987 BSI 11-1999 i Contents Page Committees responsible Inside front cover Foreword ii 1 Scope 1 2 Definitions 1 3 Test preparation 2 4 Minimum test duration 3 5 Test operation 3 6 Instrumentation 4 7 Measurement procedure 5 8 Ca
9、lculations 10 9 Report 16 Appendix A Report data 22 Appendix B Calculation of production rate of unweighed ash 37 Appendix C Radiation, convection and conduction losses for boilers of conventional design 37 Appendix D Guiding principles 38 Appendix E Selection of assessment procedure 40 Figure 1 Dia
10、gram of heat flows in and out of the unit 42 Figure 2 Boundary points of unit 43 Table 1 Minimum duration of tests 3 Table 2 Measurement tolerances 6 Table 3 Symbols and units 17 Table 4 Typical radiation, convection and conduction losses from water-tube and shell boilers 38 Table 5 Typical radiatio
11、n, convection and conduction losses from sectional hot water boilers 38 Publications referred to Inside back coverBS845-2:1987 ii BSI 11-1999 Foreword This Part of BS845 has been prepared under the direction of the Refrigeration, Heating and Air Conditioning Standards Committee. Together with BS845-
12、1 it supersedes BS845:1972 which is withdrawn. The revised edition of BS845 describes, in two Parts, the procedures that should be used and the data that should be collected in order to obtain an assessment of the thermal performance of steam, hot water or high temperature heat transfer fluid boiler
13、s, generally of output greater than44kW. The test results may be based on either the net or the gross calorific value of the fuel. The tests described in this British Standard are for thermal performance only but are based on the assumption that boilers are operated during the tests in such a manner
14、 as to comply with relevant safety requirements and the requirements of national environmental legislation. BS845 is published in two separate Parts as follows: Part 1: provides a concise but complete procedure and is convenient for boilers which are thermodynamically simple, i.e.having a single maj
15、or source of heat input and a simple water or steam or high temperature heat transfer fluid; Part 2: provides a comprehensive procedure suitable for all boilers, including those with multiple thermal flows to and from the boiler. Part 2 is intended for testing boiler plant of any size burning any of
16、 the fuels available to commerce and industry. It may be used for contractual tests or for any subsequent test at full or part output and is suitable for testing all types of boiler including waste heat and electric boilers. Allowance is made for the use of fluidized bed combustion and for the use o
17、f domestic refuse as fuel. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pag
18、es This document comprises a front cover, an inside front cover, pagesi andii, pages1 to44, an inside back cover and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover.BS8
19、45-2:1987 BSI 11-1999 1 1 Scope This Part of BS845 describes a comprehensive procedure for conducting thermal performance tests on steam, hot water or high temperature heat transfer fluid boilers to give results within a tolerance of2percentage points 1)and for presenting the results in tabular form
20、. This Part makes use of both the direct and the indirect methods of test. Test results are based on either the gross or the net calorific value of the fuel. This comprehensive procedure is suitable for all boilers, including those with multiple thermal flows to and from the boiler. NOTEThe titles o
21、f the publications referred to in this standard are listed on the inside back cover. 2 Definitions For the purposes of this Part of BS845 the following definitions apply. 2.1 unit a steam, hot water or high temperature heat transfer fluid boiler, generally of output greater than44kW, including firin
22、g equipment, together with ancillary plant or equipment, such as superheater, economizer, air heater, fans and pumps lying within the unit boundary (as indicated in Figure 1 and Figure 2) 2.2 solid fuel any fuel in the solid state, including wastes with declared characteristics 2.3 liquid fuel petro
23、leum fuel oils in accordance with BS2869 or any other fuel in the liquid state with declared characteristics 2.4 gaseous fuel manufactured gas (first family), natural gas (second family) or LPG, i.e.propane or butane, (third family) or any other gaseous fuel with declared characteristics 2.5 gross c
24、alorific value the amount of heat liberated by the complete combustion, under specified conditions, of unit volume of a gas or unit mass of a solid or liquid fuel in the determination of which the water produced by combustion of the fuel is assumed to be completely condensed and its latent and sensi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS84521987METHODSFORASSESSINGTHERMALPERFORMANCEOFBOILERSFORSTEAMHOTWATERANDHIGHTEMPERATUREHEATTRANSFERFLUIDSCOMPREHENSIVEPROCEDURE

链接地址:http://www.mydoc123.com/p-547375.html