1、BRITISH STANDARD BS 8425:2003 Code of practice for installation of laminate floor coverings ICS 91.180; 97.150 BS 8425:2003 This British Standard was published under the authority of the Standards Policy and Strategy Committee on 7 July 2003 BSI 7 July 2003 The following BSI references relate to the
2、 work on this British Standard: Committee reference PRI/60 Draft for comment 03/100121 DC ISBN 0 580 42114 7 Committees responsible for this British Standard The preparation of this British Standard was entrusted to PRI/60, Resilient floor coverings, upon which the following bodies were represented:
3、 British Adhesives and Sealants Association British Railways Board Contract Flooring Association Cork Industry Federation Health and Safety Executive Industrial Cleaning Machine Manufacturers Association Institute of Chartered Arbitrators RAPRA Technology Ltd SATRA Technology Centre UK Cleaning Prod
4、ucts Industry Association United Kingdom Resilient Flooring Association Wood Panel Industries Federation Amendments issued since publication Amd. No. Date CommentsBS 8425:2003 BSI 7 July 2003 i Contents Page Committees responsible Inside front cover Foreword ii 1S c o p e 1 2 Normative references 1
5、3T e r m s a n d d e f i n i t i o n s 1 4 Exchange of information 2 5 Sub-floors 3 6M a t e r i a l s 8 7I n s t a l l a t i o n 9 8C o m p l e t i o n 1 1 Annex A (normative) Dampness testing 12 Figure A.1a) Typical apparatus using hygometer 14 Figure A.1b) Typical apparatus using rh probe 15BS 84
6、25:2003 ii BSI 7 July 2003 Foreword This British Standard has been prepared by Technical Committee PRI/60. As a code of practice, this British Standard takes the form of guidance and recommendations. It should not be quoted as if it were a specification and particular care should be taken to ensure
7、that claims of compliance are not misleading. This publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages Thi
8、s document comprises a front cover, an inside front cover, pages i and ii, pages 1 to 15 and a back cover. The BSI copyright notice displayed in this document indicates when the document was last issued.BS 8425:2003 BSI 7 July 2003 1 1 Scope This British Standard gives recommendations for the instal
9、lation of laminate floor coverings in new or existing buildings. Generally, laminate floor coverings are installed as floating floors but, in some applications, they can be integrally glued to the subfloor. This British Standard only details suitable methods for floating floor installation and advis
10、es on the selection of materials required for their implementation. 2 Normative references The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced doc
11、ument (including any amendments) applies. BS 7916, Code of practice for the selection and application of particleboard, oriented strand board (OSB), cement bonded particle board and wood fibre boards for specific purposes. BS 7953, Entrance flooring systems Selection, installation and maintenance. B
12、S 8102, Code of practice for protection of structures against moisture from the ground. BS 8204-1:2002, Screeds, bases and in-situ floorings Part 1: Concrete bases and cement sand levelling screeds to receive floorings Code of practice. BS EN 204, Classification of thermoplastic wood adhesives for n
13、on-structural applications. BS EN 13329, Laminate floor coverings Specifications, requirements and test methods. 3 Terms and definitions For the purposes of this British Standard, the following terms and definitions apply. 3.1 fabricated substrate manufactured board made from wood, wood particles or
14、 wood fibres in sheet form, gypsum, etc. to provide suitable a surface to receive the specified floor covering 3.2 screed layer of well compacted material, commonly a mixture of cement and aggregate, applied in situ to a concrete base at the appropriate thickness 3.3 levelling layer layer of compact
15、ed material, applied in situ to a sound base or screed where there is a need to raise the level of the floor surface to level a floor that is out of true, or to give a uniform absorbency where water-based adhesives are to be used 3.4 underlayment thin layer of compacted material, applied in situ to
16、a sound base, screed or substrate to provide a suitable finish to receive adhesive, the underlay or floor covering 3.5 flowing screed in situ applied material that sets hydraulically or by chemical cure NOTE It is normally a proprietary compound to be used in accordance with manufacturers recommenda
17、tions. It is poured or pumped directly to the concrete slab to form a smooth level surface, ready to receive most floor coveringsBS 8425:2003 2 BSI 7 July 2003 3.6 anhydrite screed formulated flowing screed based on calcium sulfate 3.7 membrane thin flexible sheet, at least 0.15 mm thick, for exampl
18、e of polythene, that is placed directly onto the surface of the mineral subfloor to protect the laminate floor covering from residual damp 4 Exchange of information 4.1 General In order for the correct floor covering to be installed in appropriate conditions, at the right time, etc., it is essential
19、 that all parties have a clear understanding of the requirements of the project, e.g. new build or refurbishment, and of the implications for all concerned. To ensure that this is achieved, it is essential that there is wide consultation between all parties involved in the project, including sub-con
20、tractors and materials suppliers. This consultation should start early in the design stage but will be necessary throughout the contract, especially should requirements or time scales change and as new sub-contract work is initiated. As each project will be unique, it is impossible to give a definit
21、ive list of the information to be exchanged, but the following (4.2 to 4.9) are typical examples. 4.2 Project The name and location of projects and personnel involved in pre-contract negotiations should be identified. 4.3 Contract conditions A programme for commencement and completion of work should
22、 be defined, including any specific requirement for sequenced completion. 4.4 Special attendance Access, unloading, hoisting and storage facilities, heat, light and power and any additional items considered necessary to expedite the work should be provided. 4.5 Design 4.5.1 General The following lay
23、out and specifications, based on building type and occupational uses, should be provided: a) type of use: building, rooms; b) type and density of foot and/or wheeled traffic; c) specific requirements: fire resistance period, acoustic absorption level; d) particulars of use: staining, potentially abr
24、asive conditions. 4.5.2 Floor details The completed drawings/specification should provide comprehensive information on: a) whether upper floor, ground floor or below ground level; b) whether ground-supported or suspended construction; c) particulars of any under floor heating installation or securit
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS84252003CODEOFPRACTICEFORINSTALLATIONOFLAMINATEFLOORCOVERINGS 多层 楼面 面层 安装 实施 规程 PDF

链接地址:http://www.mydoc123.com/p-547353.html