BS 842-1965 Specification for a c voltage-operated earth-leakage circuit breakers《交流电压控制的接地保护断路器规范》.pdf
《BS 842-1965 Specification for a c voltage-operated earth-leakage circuit breakers《交流电压控制的接地保护断路器规范》.pdf》由会员分享,可在线阅读,更多相关《BS 842-1965 Specification for a c voltage-operated earth-leakage circuit breakers《交流电压控制的接地保护断路器规范》.pdf(22页珍藏版)》请在麦多课文档分享上搜索。
1、BRITISH STANDARD BS 842:1965 Incorporating Amendment No. 1 Specification for A.C. voltage-operated earth-leakage circuit breakers UDC 621.316.57.025:621.316.9BS842:1965 This British Standard, having been approved by the ElectricalIndustry StandardsCommittee and endorsed by the Chairman of theEnginee
2、ring Divisional Council, was published under theauthority of the General Council on 15November1965 First publishedJune1939 First revisionNovember1965 BSI 10-1999 The following BSI references relate to the work on this standard: Committee references ELE/10 and ELE/10/18 Draft for comment D64/1587 ISB
3、N 0 580 01330 8 Co-operating organizations The Electrical Industry Standards Committee under whose supervision this British Standard was prepared consists of representatives from the following Government departments and scientific and industrial organizations: Associated Offices Technical Committee
4、Association of Consulting Engineers* Association of Mining Electrical and Mechanical Engineers* Association of Supervising Electrical Engineers* British Electrical and Allied Manufacturers Association* British Railways Board* Cable Makers Association* Crown Agents for Oversea Governments and Adminis
5、trations* Electric Lamp Industry Council Electric Light Fittings Association Electrical Contractors Association (Incorporated)* Electrical Contractors Association of Scotland Electrical Research Association* Electricity Council, The Generating Board and the Area Boards in England and Wales* Electron
6、ic Engineering Association Engineering Equipment Users Association* Independent Cable Makers Association Institution of Electrical Engineers* Ministry of Aviation* Ministry of Defence, Army Department* Ministry of Defence, Navy Department* Ministry of Labour (H.M. Factory Inspectorate)* Ministry of
7、Power* Ministry of Public Building and Works* Municipal Passenger Transport Association (Incorporated) National Inspection Council for Electrical Installation Contracting* National Physical Laboratory (Ministry of Technology) Oil Companies Materials Association* Post Office* Public Transport Associa
8、tion (Incorporated) South of Scotland Electricity Board* The Government departments and scientific and industrial organizations marked with an asterisk in the above list, together with the following, were directly represented on the committee entrusted with the preparation of this British Standard:
9、Association of Short-circuit Testing Authorities Engineer Surveyors Association Lloyds Register of Shipping London Transport Board National Coal Board Amendments issued since publication Amd. No. Date Comments 3259 March 1980 Indicated by a sideline in the marginBS842:1965 BSI 10-1999 i Contents Pag
10、e Co-operating organizations Inside front cover Foreword iii 1 Scope 1 2 Definitions 1 3 Service conditions 1 4 Rating 1 5 Standard arrangement of poles 2 6 Standard voltage ratings 2 7 Standard current ratings 2 8 Frequency 2 9 Marking 2 10 Terminal identification 2 11 Temperature rise 2 12 Earth-l
11、eakage performance 3 13 Test device 3 14 Mains operated trip coils 3 15 Construction 3 16 Operating mechanism 4 17 Connection arrangements 4 18 Test requirements general 4 19 Test certificates 4 20 Type tests 4 21 Temperature rise test 5 22 Operation of the test device 5 23 Endurance test 5 24 Makin
12、g and breaking test 6 25 Through current test 6 26 Resistance to lightning surges 6 27 Routine tests 7 28 Performance test 7 29 Speed of operation 7 30 Performance of test device 7 31 Mains voltage test on tripping device 7 32 High-voltage test 7 Appendix A Service conditions 8 Appendix B Applicatio
13、n of earth-leakage circuit-breakers 8 Appendix C Method of installation 8 Appendix D Function of the test device 9 Appendix E Effect of earth-electrode resistance 10BS842:1965 ii BSI 10-1999 Page Figure 1 Typical test circuit for through current test 11 Figure 2 Circuit for surge test 12 Figure 3 Ty
14、pical voltage-operated earth-leakage circuit-breaker installation.Note insulated lead from “e” to earth electrode 13 Figure 4 Typical voltage distribution in soil surrounding a2m rod electrode 14 Table 1 Voltage ratings 2 Table 2 Current ratings 2 Table 3 Temperature rise 3 Table 4 Operating limits
15、3 Table 5 Terminal capacities 4 Table 6 Endurance test sequence 6 Table 7 Prospective-current values 6BS842:1965 BSI 10-1999 iii Foreword This standard makes reference to the following British Standards: BS 2757, Classification of insulating materials for electrical machinery and apparatus on the ba
16、sis of thermal stability in service. BS 3042, Standard test finger (for checking protection against electric shock). This British Standard for voltage-operated air-break earth-leakage circuit-breakers is an extensive revision of the1939 edition to take account of modern developments in earth-leakage
17、 protection and in the design and production of small circuit-breakers. The voltage-operated type of earth-leakage circuit-breaker is intended to prevent a dangerous potential difference persisting between the general mass of earth and accessible installation metal work. The operation of the device
18、will depend not only upon this potential difference but also upon the earth-leakage circuit-breaker earth-electrode resistance (seeAppendix E). A voltage-operated earth-leakage circuit-breaker may incorporate over-current protection. In such instances it is necessary for the earth-leakage circuit-br
19、eaker to comply with the requirements of this standard and also with the relevant requirements in the appropriate circuit-breaker standard. In this connection, attention is drawn to BS3871-1 1)and BS862 2) . Appendices have been included to assist users in the proper application of voltage-operated
20、earth-leakage circuit-breakers and attention is particularly directed to these. A British Standard for the current-operated type of earth-leakage circuit-breaker is in the course of preparation and this type of circuit-breaker will be more suitable for low-values of earth-loop impedance. NOTEIn plac
21、e of the customary, but incorrect use of the ounce as a unit of force, the unit called ounce-force (abbreviation ozf) has been used in this standard. This is the force which, when acting on a body of mass one ounce, gives it an acceleration equal to that of standard gravity. A British Standard does
22、not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for their correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside
23、 front cover, pages i to iv, pages1 to 14 and a back cover. This standard has been updated (see copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on the inside front cover. 1) BS3871, “Miniature and moulded-case circuit-breakers”, Part1, “Miniatu
24、re air-break circuit-breakers for a.c. circuits”. 2) BS862, “Air-break circuit-breakers (including totally enclosed and flameproof types) for voltages not exceeding660 volts”.iv blankBS842:1965 BSI 10-1999 1 1 Scope This British Standard specifies requirements for a.c. voltage-operated earth-leakage
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS8421965SPECIFICATIONFORACVOLTAGEOPERATEDEARTHLEAKAGECIRCUITBREAKERS 交流 电压 控制 接地 保护 断路器 规范 PDF

链接地址:http://www.mydoc123.com/p-547348.html