BS 7856-2017 Specification for special design and other features of alternating current watthour meters for active energy for use in the UK (Accuracy Classes A and B)《在英国使用的有功电量用交流.pdf
《BS 7856-2017 Specification for special design and other features of alternating current watthour meters for active energy for use in the UK (Accuracy Classes A and B)《在英国使用的有功电量用交流.pdf》由会员分享,可在线阅读,更多相关《BS 7856-2017 Specification for special design and other features of alternating current watthour meters for active energy for use in the UK (Accuracy Classes A and B)《在英国使用的有功电量用交流.pdf(34页珍藏版)》请在麦多课文档分享上搜索。
1、BS 7856:2017Specification for special design and other features of alternating current watthour meters for active energy for use in the UK (Accuracy Classes A and B)BSI Standards PublicationWB11885_BSI_StandardCovs_2013_AW.indd 1 15/05/2013 15:06Publishing and copyright informationThe BSI copyright
2、notice displayed in this document indicates when the document was last issued. The British Standards Institution 2017Published by BSI Standards Limited 2017ISBN 978 0 580 95803 8ICS 17.220.20The following BSI references relate to the work on this document: Committee reference PEL/13 Draft for commen
3、t 16/30348626 DCAmendments/corrigenda issued since publicationDate Text affected BS 7856:2017 BRITISH STANDARD THE BRITISH STANDARDS INSTITUTION 2017 ALL RIGHTS RESERVEDForeword ii1 Scope 12 Normative references 13 Terms and definitions 14 Mechanical features 2Table 1 Dimensions and spacing of fixin
4、g holes and terminals 3Figure 1 Spacing of fixing holes and terminals for single-phase, two-wire meter 45 Electrical features 5Table 2 Standard currents for meters of Class A or Class B 5Figure 2 Diagrams of connections for a single-phase, two-wire, one-rate meter 7Figure 3 Diagrams of connections a
5、nd graphical symbols for a two-element meter used on three-wire systems 8Figure 4 Diagrams of connections and graphical symbols for a two-element meter used on a two-phase, four-wire system 9Figure 5 Diagrams of connections and graphical symbols for a three-element meter used on a three-phase, four-
6、wire system 106 Other features 11Annex A (normative) Test method of a terminals ability to safely clamp standard UK cables 12Figure A.1 Test arrangement for clamping ability of a meter terminal 13Annex B (normative) External rate switching logic for multi-rate meters 14Table B.1 Sequence for multi-r
7、ate registers having two to eight rates 14Annex C (normative) Long-term overcurrent test requirements 15Annex D (normative) Performance criteria for load switches inside meters 16Table D.1 Performance criteria for supply control and load control switches 16Figure D.1 Polyphase meter supply control s
8、witch test timing 17Figure D.2 Contact resistance derived from mV drop measured at meter terminals at Imax18Annex E (normative) Sealing criteria 19Annex F (informative) Operational considerations related to switches inside meters 20Figure F.1 Typical heating in a 100 AImaxmeter when subjected to 1.4
9、5 * Imax21Table F.1 Thermal stresses on a 100 A SCS protected by various OCPD ratings 22Table F.2 Characteristics of OCPDs in common domestic use in the UK 23Figure F.2 Current levels for determining OCPD characteristics 24Bibliography 26Contents PageSummary of pagesThis document comprises a front c
10、over, and inside front cover, pages i to iv, pages 1 to 26, an inside back cover and a back cover.BRITISH STANDARD BS 7856:2017 THE BRITISH STANDARDS INSTITUTION 2017 ALL RIGHTS RESERVED IForewordPublishing informationThis British Standard is published by BSI Standards Limited, under licence from Th
11、e British Standards Institution, and came into effect on 31 July 2017. It was prepared by Technical Committee PEL/13, Electricity meters. A list of organizations represented on this committee can be obtained on request to its secretary.SupersessionThis British Standard supersedes BS 7856:2013, which
12、 is withdrawn.Relationship with other publicationsThe standard specifies several conditions which are more stringent than currently exist within other European metering standards, reflecting the differences in working practices that exist between the United Kingdom and other European Union member st
13、ates. It is, however, important to note that this British Standard is intended to augment the provisions of certain European standards (see Clause 2, “Normative references”) and so, in instances where this document is non-prescriptive, the provisions of these other standards prevail and are therefor
14、e to be taken into account.Information about this documentThis standard has been revised to take account of the introduction of the IEC standard for electricity meter safety (IEC 62052-31) and developments in the UK metering market, principally the roll-out of smart metering to the residential marke
15、t. The decision to further revise the standard came about because of: the incorporation of a supply control switch in every meter, particularly with regard to design considerations related to appropriate utilization categories, switch life (endurance) concerns and the thermal stresses placed upon su
16、ch switches during overcurrent episodes. Furthermore, to give advice relating to supply control switches within polyphase meters in order to avoid issues due to partial switching arising from fault conditions; the inadequacies of some forms of service fusing as a means of providing protection to met
17、ering equipment and the need to align the overload requirements with British national specifications e.g. 1.45 Imax; the need to ensure that the provisions for installation sealing arrangements continue to meet the national specifications within the MOCOPA N1.In addition, legacy sections relating to
18、 meters of older design have been removed. Reference to current transformer operated metering has also been removed as the majority of the standard no longer applies to such metering equipment. However, at the time of writing, consideration is being given to additional work to incorporate current tr
19、ansformer operated metering in an additional standard.The decision has also been taken to convert BS 7856 from a Code of Practice to a Specification as some of the new requirements relating to the national specifications are normative and safety related.Presentational conventionsThe provisions of th
20、is standard are presented in roman (i.e. upright) type. Its requirements are expressed in sentences in which the principal auxiliary verb is “shall”.BS 7856:2017 BRITISH STANDARDII THE BRITISH STANDARDS INSTITUTION 2017 ALL RIGHTS RESERVEDCommentary, explanation and general informative material is p
21、resented in smaller italic type, and does not constitute a normative element.Where words have alternative spellings, the preferred spelling of the Shorter Oxford English Dictionary is used (e.g. “organization” rather than “organisation”).Requirements in this standard are drafted in accordance with R
22、ules for the structure and drafting of UK standards, subclause G.1.1, which states, “Requirements should be expressed using wording such as: When tested as described in Annex A, the product shall .”. This means that only those products that are capable of passing the specified test will be deemed to
23、 conform to this standard.Contractual and legal considerationsThis publication does not purport to include all the necessary provisions of a contract. Users are responsible for its correct application.Compliance with a British Standard cannot confer immunity from legal obligations.BRITISH STANDARD B
24、S 7856:2017 THE BRITISH STANDARDS INSTITUTION 2017 ALL RIGHTS RESERVED IIITHIS PAGE DELIBERATELY LEFT BLANKBS 7856:2017 BRITISH STANDARD1 ScopeThis British Standard specifies requirements for special design and other features of newly manufactured directly connected alternating current watthour mete
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS78562017SPECIFICATIONFORSPECIALDESIGNANDOTHERFEATURESOFALTERNATINGCURRENTWATTHOURMETERSFORACTIVEENERGYFORUSEINTHEUKACCURACYCLASSESAANDB

链接地址:http://www.mydoc123.com/p-547091.html