1、BRITISH STANDARD BS 5041-1: 1987 Incorporating Amendment No.1 Fire hydrant systems equipment Part 1: Specification for landing valves for wet risers UDC 614.843.1 + 621.643.51BS5041-1:1987 This British Standard, having been prepared under the directionof the Fire Standards Committee, was published u
2、nderthe authority of the BoardofBSI and comes intoeffecton 31 March 1987 BSI 03-1999 First published September 1975 First revision March 1987 The following BSI references relate to the work on this standard: Committee reference FSM/6 Draft for comment 86/35835 DC ISBN 0 580 15721 0 Committees respon
3、sible for this British Standard The preparation of this British Standard was entrusted by the Fire Standards Committee (FSM/-) to Technical Committee FSM/6, upon which the following bodies were represented: Association of County Councils Association of Metropolitan Authorities British Coal British F
4、ire Services Association British Plastics Federation British Valve Manufacturers Association Ltd. Chief and Assistant Chief Fire Officers Association Convention of Scottish Local Authorities Copper Development Association Department of the Environment (Property Services Agency) Department of Transpo
5、rt (Marine Directorate) Fire Extinguishing Trades Association Fire Offices Committee Fire Protection Association Greater London Council Home Office Institution of Fire Engineers Ministry of Defence Royal Institute of British Architects The following body was also represented in the drafting of the s
6、tandard, through subcommittees and panels: British Fire Protection Systems Association Ltd. Amendments issued since publication Amd. No. Date of issue Comments 5912 September 1988 Indicated by a sideline in the marginBS5041-1:1987 BSI 03-1999 i Contents Page Committees responsible Inside front cover
7、 Foreword ii Section 1. General 1 Scope 1 2 Definitions 1 3 Valve types 1 4 Classification by pressure rating 1 5 Nominal inlet sizes 2 6 Temperature rating 2 7 Marking 2 Section 2. Design 8 Materials 3 9 Valve bodies 3 10 Valve inlets 3 11 Valve outlets 3 12 Bonnets 3 13 Stems 3 14 Stem sealing on
8、globe valves 5 15 Glands on globe valves 5 16 Disks and disk facings 5 17 Handwheels and operation 5 18 Bolting 5 19 Pressure retention 5 20 Strap 5 21 Blank cap and chain 5 22 Water flow rate and outlet pressure 5 23 Outlet pressure at restricted pressure (high pressure valves only) 6 24 Resistance
9、 to high temperature (diaphragm valves only) 6 Section 3. Production testing requirements and test certificate 25 Hydrostatic tests 7 26 Pressure control test (high pressure valves only) 7 27 Test certificate 7 Appendix A Test methods 8 Appendix B Recommendations for the information to be supplied b
10、y thepurchaser to the manufacturer 9 Figure 1 Valve types 1 Table 1 Choice of materials for components and parts 4 Table 2 Bolting for valves 5 Table 3 Body test pressures and durations 8 Table 4 Seat test pressures and durations 8 Publications referred to Inside back coverBS5041-1:1987 ii BSI 03-19
11、99 Foreword This revision of BS5041-1 has been prepared under the direction of the Fire Standards Committee and supersedes BS5041-1:1975, which is withdrawn. It specifies requirements for valves suitable for use on wet risers of either high or low pressure installations. BS5041-1:1975 was restricted
12、 to copper alloy globe valves but in this revision requirements for diaphragm valves are included. The subjects of the other Parts in the BS5041 series of general specifications for fire hydrant systems equipment are as follows. Part 2: Landing valves for dry risers; Part 3: Inlet breechings for dry
13、 riser inlets; Part 4: Boxes for landing valves for dry risers; Part 5: Boxes for foam inlets and dry riser inlets. These Parts give detailed requirements for most of the other special items required for wet and dry risers described in BS5306-1. In this standard metric values are given in SI units;
14、for further information reference should be made to BS3763. Some nominal bores and thread sizes are given in inches to accord with the standards referred to. A British Standard does not purport to include all the necessary provisions of a contract. Users of British Standards are responsible for thei
15、r correct application. Compliance with a British Standard does not of itself confer immunity from legal obligations. Summary of pages This document comprises a front cover, an inside front cover, pages i and ii, pages1 to10, an inside back cover and a back cover. This standard has been updated (see
16、copyright date) and may have had amendments incorporated. This will be indicated in the amendment table on theinside front cover.BS5041-1:1987 BSI 03-1999 1 Section 1. General 1 Scope This Part of BS5041 specifies requirements for copper alloy globe valves generally complying with BS5154 and diaphra
17、gm valves generally complying with BS5156, both suitable for installation as landing valves on wet risers. The valves have screwed or flanged inlets and also delivery hose connections complying with BS336. This standard covers valves of nominal pressure (PN) designations15bar and 20bar and nominal i
18、nlet sizes DN40 to DN65 for flanged ends and 1 and2 for screwed ends. NOTE 1Unless otherwise stated all pressures are gauge pressures expressed in bar: 1bar = 10 5N/m 2= 100kPa. NOTE 2Information which the purchaser is recommended to supply to the manufacturer is given in Appendix B and does not for
19、m part of the specification. NOTE 3The titles of the publications referred to in this standard are listed on the inside back cover. 2 Definitions For the purposes of this Part of BS5041, the following definitions apply. 2.1 wet riser (wet rising main) a vertical pipe installed in a building for fire
20、 fighting purposes, permanently charged with water from a pressurized supply, and fitted with valves and outlet connections at specified points 2.2 landing valve an assembly comprising a valve and outlet connection from a wet or dry riser 3 Valve types Valves, whether globe or diaphragm, shall be of
21、 the horizontal, bib-nosed, oblique or right-angle type, the general forms being illustrated in Figure 1. 4 Classification by pressure rating 4.1 General Valves shall be classified as low pressure or high pressure according to the nominal inlet working pressure for which they are suitable. 4.2 Low p
22、ressure valves Low pressure valves shall be suitable for use at nominal inlet pressures up to 15bar. 4.3 High pressure valves High pressure valves shall be suitable for use at nominal inlet pressures up to 20bar. Figure 1 Valve typesBS5041-1:1987 2 BSI 03-1999 5 Nominal inlet sizes 5.1 Flanged end v
23、alves The nominal inlet size (DN) shall be 40, 50 or 65. 5.2 Screwed end valves The nominal inlet size (DN) shall be 1, 2 or 2. 6 Temperature rating Both low pressure and high pressure valves shall be suitable for continuous use at their nominal pressure rating throughout the temperature range from
24、0C to 38C. 7 Marking 7.1 General Each valve shall be marked with the following: a) the letters “LP” (for low pressure valves) or “HP” (for high pressure valves) in a position which will be visible after the valve has been installed; b) the nominal size; c) the manufacturers name or trademark; d) the
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- BS504111987FIREHYDRANTSYSTEMSEQUIPMENTSPECIFICATIONFORLANDINGVALVESFORWETRISERS 消防栓 系统 设备 部分 湿式水嘴 接地

链接地址:http://www.mydoc123.com/p-544811.html