ASTM F2815-2010(2014) Standard Practice for Chemical Permeation through Protective Clothing Materials Testing Data Analysis by Use of a Computer Program《防护服材料化学渗透性的标准方法使用计算机程序进行试验数.pdf
《ASTM F2815-2010(2014) Standard Practice for Chemical Permeation through Protective Clothing Materials Testing Data Analysis by Use of a Computer Program《防护服材料化学渗透性的标准方法使用计算机程序进行试验数.pdf》由会员分享,可在线阅读,更多相关《ASTM F2815-2010(2014) Standard Practice for Chemical Permeation through Protective Clothing Materials Testing Data Analysis by Use of a Computer Program《防护服材料化学渗透性的标准方法使用计算机程序进行试验数.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F2815 10 (Reapproved 2014)Standard Practice forChemical Permeation through Protective Clothing Materials:Testing Data Analysis by Use of a Computer Program1This standard is issued under the fixed designation F2815; the number immediately following the designation indicates the year ofor
2、iginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the calculations of all the perme-ation
3、parameters related to Test Method F739, ISO 6529, andPractice D6978 standards by use of a computer program,referred to as “Permeation Calculator” (DHHS (NIOSH) Pub-lication No. 2007 143c).2,31.2 The practice is applicable to both open loop and closedloop permeation tests. The closed loop test includ
4、es continuoussampling and discrete sampling. The discrete sampling in-cludes tests when sample volume is replaced and also whensample volume is not replaced. For an open loop permeationtest, the computer program also allows permeation data fileswith variable sampling flow rate. Refer to Test Method
5、F739for more details about the different types of the permeationtesting systems.1.3 This practice is applicable to the most typical perme-ation behavior, that is, Type A, where the permeation ratestabilizes at a “steady-state” value. It does not apply to theother types of permeation behaviors. Refer
6、 to Test MethodF739 for more details about the various permeation behaviors.1.4 This practice is not applicable to Test Method F1383because the permeation behavior is different under conditionsof intermittent contact than under conditions of continuouscontact.1.5 This practice does not address the p
7、rocedure of perme-ation testing. Refer to Test Method F739, ISO 6529, or PracticeD6978 for the procedures in detail if needed.2. Referenced Documents2.1 ASTM Standards:4D6978 Practice for Assessment of Resistance of MedicalGloves to Permeation by Chemotherapy DrugsF739 Test Method for Permeation of
8、Liquids and Gasesthrough Protective Clothing Materials under Conditions ofContinuous ContactF1194 Guide for Documenting the Results of ChemicalPermeation Testing of Materials Used in Protective Cloth-ingF1383 Test Method for Permeation of Liquids and Gasesthrough Protective Clothing Materials under
9、Conditions ofIntermittent ContactF1494 Terminology Relating to Protective Clothing2.2 ISO Standards:5ISO 6529 Protective ClothingProtection againstChemicalsDetermination of Resistance of ProtectiveClothing Materials to Permeation by Liquids and Gases3. Terminology3.1 Definitions:3.1.1 analytical tec
10、hnique, na procedure whereby theconcentration of a challenge chemical in a collection mediumis quantitatively determined.3.1.1.1 DiscussionThe detailed steps for these proceduresare often specific to individual chemical and collection mediumcombinations. Applicable techniques include but are not lim
11、-ited to flame ionization, photo ionization, electro-chemical, andultraviolet and infrared spectrophotometry, gas and liquidchromatography, colorimetry, length-of-stain detector tubes,and radionuclide tagging/detection counting.3.1.2 breakthrough detection time, nthe elapsed time mea-sured from the
12、start of the test to the sampling time thatimmediately precedes the sampling time at which the testchemical is first detected.1This practice is under the jurisdiction of ASTM Committee F23 on PersonalProtective Clothing and Equipment and is the direct responsibility of SubcommitteeF23.30 on Chemical
13、s.Current edition approved May 1, 2014. Published May 2014. Originallyapproved in 2010. Last previous edition approved in 2010 as F281510.DOI:10.1520/F281510R14.2Gao P, Weise T, and Tomasovic B 2009 Development of a computer programfor permeation testing data analysis. Journal of Occupational solid
14、chemicals move through voids in the materials assolids, liquids as liquids, and gases as gases. Penetration is adistinctly different mechanism from permeation.3.1.12 permeation, nfor chemical protective clothing, themovement of chemicals as molecules through protective cloth-ing materials by the pro
15、cesses of (1) absorption of the chemicalinto the contact surface of the material, (2) diffusion of theabsorbed molecules throughout the material, and (3) desorptionof the chemical from the opposite surface of the material.3.1.12.1 DiscussionPermeation is a distinctly differentmechanism from penetrat
16、ion.3.1.13 protective clothing, nan item of clothing that isspecifically designed and constructed for the intended purposeof isolating all or part of the body from a potential hazard; orisolating the external environment from contamination by thewearer of the clothing.3.1.14 standardized breakthroug
17、h time, nthe first time atwhich the permeation rate reaches 0.1 g/cm2/min.3.1.15 steady-state permeation rate, na constant rate ofpermeation that occurs after breakthrough when all forcesaffecting permeation have reached equilibrium.3.1.16 test chemical, nsolid, liquid, gas or mixturethereof, used t
18、o evaluate the performance of a protectiveclothing material.4. Summary of Practice4.1 The computer program used in this practice calculatesall the permeation parameters listed in Test Method F739, ISO6529, and Practice D6978, including standardized break-through time, normalized breakthrough detecti
19、on time, break-through detection time, minimum breakthrough detection time(if applicable), steady-state permeation rate, cumulative per-meation at a given elapsed time, elapsed time at a givencumulative permeation, average permeation rate, and maxi-mum permeation rate if it is an open loop permeatio
20、n test.4.2 The operation of the computer program involves thefollowing steps:4.2.1 Data Input to the Computer ProgramInput a perme-ation testing data file that contains data points in time versusconcentration. The data must be in a spreadsheet software filewith a minimum of seven data points before
21、the breakthroughpoint and the total number of data points can not exceed 5000.The number of significant figures used for the input data willaffect the number of significant figures reported for thepermeation parameters, so appropriate significant figuresshould be used. Refer to Appendix X1 for detai
22、ls in data filerequirements.4.2.2 AnalysisAfter importing the data file and enteringrequired information, the program determines the permeationparameters based on a series of strategies and approaches.4.2.3 OutputUpon completion, the program displays allthe permeation parameters together with releva
23、nt informationand the permeation curve in a spreadsheet software or a textfile-formatted report.5. Significance and Use5.1 Data analysis for chemical protective clothing perme-ation testing involves a number of equations and experimentalfactors. Possible calculation errors are critical issues whende
24、termining permeation parameters. Because the calculationsof some of the permeation parameters are mathematicallycomplex, this computer program will be useful.5.2 This practice is to help researchers and industrial hy-gienists avoid labor intensive hand calculations of the perme-ation parameters. Fro
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF281520102014STANDARDPRACTICEFORCHEMICALPERMEATIONTHROUGHPROTECTIVECLOTHINGMATERIALSTESTINGDATAANALYSISBYUSEOFACOMPUTERPROGRAM

链接地址:http://www.mydoc123.com/p-539528.html