《ASTM F667 F667M-2016 Standard Specification for 3 through 24 in Corrugated Polyethylene Pipe and Fittings《3至24英寸聚乙烯波纹管和配件的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM F667 F667M-2016 Standard Specification for 3 through 24 in Corrugated Polyethylene Pipe and Fittings《3至24英寸聚乙烯波纹管和配件的标准规格》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F667/F667M 15F667/F667M 16Standard Specification for3 through 24 in. Corrugated Polyethylene Pipe and Fittings1This standard is issued under the fixed designation F667/F667M; the number immediately following the designation indicates the yearof original adoption or, in the case of revis
2、ion, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers requirements and test methods for materials, workmanship, dimensions, perf
3、orations, pipestiffness, elongation, joint separation resistance, quality of extruded polyethylene, brittleness, bond, and marking of corrugatedpolyethylene (PE) pipe and fittings. It covers nominal sizes 3 in. 76 mm, 4 in. 102 mm, 5 in. 127 mm 6 in. 152 mm, 8 in.203 mm, 10 in. 254 mm, 12 in. 305 mm
4、, 15 in. 381 mm, 18 in. 457 mm, and 24 in. 610 mm.1.2 This specification covers tubularly extruded, spirally laminated, and rotationally molded corrugated polyethylene pipe.1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematicalconve
5、rsions to SI units that are provided for information only and are not considered standard.1.4 The following precautionary caveat pertains only to the test method portion, Section 9, of this specification:This standarddoes not purport to address all of the safety concerns, if any, associated with its
6、 use. It is the responsibility of the user of thisstandard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D618 Practice for Conditioning Plastics for TestingD2412 Test Method for D
7、etermination of External Loading Characteristics of Plastic Pipe by Parallel-Plate LoadingD2444 Test Method for Determination of the Impact Resistance of Thermoplastic Pipe and Fittings by Means of a Tup (FallingWeight)D3350 Specification for Polyethylene Plastics Pipe and Fittings MaterialsF412 Ter
8、minology Relating to Plastic Piping SystemsF449 Practice for Subsurface Installation of Corrugated Polyethylene Pipe for Agricultural Drainage or Water Table Control2.2 Federal Standard:3Fed. Std. No. 123 Marking for Shipment (Civil Agencies)2.3 Military Standard:3MIL-STD-129 Marking for Shipment an
9、d Storage3. Terminology3.1 DefinitionsDefinitions used in this specification are in accordance with Terminology F412, unless otherwise noted.3.2 Definitions:3.2.1 splitany break or crack that extends through the wall.3.2.2 creasea deformation that cannot be removed like a dent: generally associated
10、with wall buckling.4. Significance and Use4.1 Corrugated PE pipe and fittings are intended for underground applications where soil provides support to their flexible walls.Their major use is to collect or convey drainage water, or both.1 This specification is under the jurisdiction ofASTM Committee
11、F17 on Plastic Piping Systems and is the direct responsibility of Subcommittee F17.65 on Land Drainage.Current edition approved April 15, 2015Feb. 1, 2016. Published May 2015March 2016. Originally approved in 1980. Last previous edition approved in 20122015 asF667 12.F667/F667M 15. DOI: 10.1520/F066
12、7_F0667-15.10.1520/F0667_F0667-16.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3 Available from Standardiz
13、ation Documents Order Desk, DODSSP, Bldg. 4, Section D, 700 Robbins Ave., Philadelphia, PA 19111-5098, http:/dodssp.daps.dla.mil.DLADocument Services Building 4/D 700 Robbins Avenue Philadelphia, PA 19111-5094 http:/quicksearch.dla.mil/This document is not an ASTM standard and is intended only to pr
14、ovide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof th
15、e standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.2 Exclusions from Recommended Use:4.2.1 Expos
16、ure to flame at any time,4.2.2 Permanent exposure to sunlight or weathering, or both, and4.2.3 Exposure to chemicals, other than those normally found in ground water, whose compatibility with the tubing and fittingsis not known.5. Materials5.1 Basic MaterialsCompounds used in the manufacture of corr
17、ugated PE drainage pipe and fittings shall have a minimumcell classification of 323410C or 333410C as defined and described in Specification D3350. Compounds that have a higher cellclassification in one or more properties are acceptable, provided the product requirements are met.NOTE 1Class B pigmen
18、ts may be substituted for Class C provided that ultraviolet protection is acceptable to the publisher as satisfactory for theintended use.5.2 Rework MaterialClean rework material, generated from the manufacturers own production of the product, may be usedby the manufacturer provided that the tubing
19、and fittings produced meet all requirements of this specification.6. General Requirements6.1 WorkmanshipThe pipe and fittings shall be homogenous throughout and essentially uniform in color, opacity, density, andother properties. The inside and outside surfaces shall be semimatte or glossy in appear
20、ance (depending on the type of plastic) andfree of chalking, sticky, or tacky material.The pipe and fitting walls shall be free of cracks, holes, blisters, voids, foreign inclusions,or other defects that are visible to the naked eye and that may affect the wall integrity. Holes deliberately placed i
21、n perforated pipeare acceptable. The surface shall be free of excessive bloom. Bloom or chalking may develop in pipe exposed to the direct raysof the sun (ultraviolet radiant energy) for extended periods; consequently, these requirements do not apply to pipe and fittings afterextended exposure to di
22、rect rays of the sun.NOTE 2Wall thickness may vary within each corrugation. Variation is acceptable provided the tubing meets all physical requirements.7. Detail Requirements7.1 General:7.1.1 The following requirements shall be met by perforated or nonperforated pipe, as applicable.7.1.2 Individual
23、results shall be used to determine compliance with the requirements, unless otherwise stated.7.2 Dimensions and Tolerances:7.2.1 Pipe:7.2.1.1 Nominal DiameterThe nominal diameter of the pipe shall be the average inside diameter rounded to the nearest wholenumber.7.2.1.2 Inside DiameterThe tolerance
24、on the nominal inside diameter shall be +3 %; 1.5 %, when measured in accordancewith 9.3.7.2.1.3 LengthThe pipe may be sold in any length agreeable to the user. Length shall not be less than 99 % of stated quantity,when measured in accordance with 9.4.7.2.2 Fittings:7.2.2.1 The maximum allowable gap
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF667F667M2016STANDARDSPECIFICATIONFOR3THROUGH24INCORRUGATEDPOLYETHYLENEPIPEANDFITTINGS3 24 英寸 聚乙烯

链接地址:http://www.mydoc123.com/p-537064.html