《ASTM F598-2000(2004) Standard Practice for Determining the Resistance of Carbonless Papers to Capsular Damage《测定无碳纸耐卷筒损伤能力的标准规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM F598-2000(2004) Standard Practice for Determining the Resistance of Carbonless Papers to Capsular Damage《测定无碳纸耐卷筒损伤能力的标准规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 598 00 (Reapproved 2004)Standard Practice forDetermining the Resistance of Carbonless Papers toCapsular Damage1This standard is issued under the fixed designation F 598; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision
2、, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 The test procedures of this practice are applicable to anycarbonless paper product that employs a coati
3、ng of micro-capsules bonded to one side of the paper wherein the activematerial within the capsules is a colorless reactant capable ofgenerating color when the capsules are broken and the con-tained solution is simultaneously transferred to a reactivereceptor surface capable of changing the chemical
4、 from acolorless to a colored condition.1.2 The procedures are designed to demonstrate the extentof damage incurred by (1) controlling the rate of slippage oftest units held in contact with each other under a calibratedweight and (2) by the controlled application of pressure to testunits held statio
5、nary with respect to each other.1.2.1 The first test procedure is designed to demonstrate theresistance to capsular damage related to plies slipping underpressure.1.2.2 The second test procedure is designed to demonstratethe resistance to capsular damage related only to pressure, suchas between plie
6、s within rolls, between sheets in a stack or dueto nip effects in web processing, converting, or end-useequipment.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of whoever uses this standard to consult andestablish ap
7、propriate safety and health practices and deter-mine the applicability of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 585 Practice for Sampling and Accepting a Single Lot ofPaper, Paperboard, Fiberboard, and Related ProductsD 685 Practice for Conditioning Paper a
8、nd Paper Productsfor TestingD 774/D 774M Test Method for Bursting Strength of PaperF 549 Terminology Relating to Carbonless Copy Products2.2 TAPPI Standard:T 425 Opacity of Paper (15/Diffuse Illuminant A, 89%Reflectance Backing and Paper Backing)32.3 ANSI Standards:IT 2.1619954IT 2.17199543. Termino
9、logy Definitions3.1 Refer to Terminology F 549.4. Summary of Practice4.1 Test Under Dynamic ConditionsA receptor (CF) testunit of fixed area is held in position under fixed pressure whilea donor test unit of specified length is drawn under it bycontrolled mechanical means. The receptor coated side o
10、f theCF sample and the donor coated side of the CB sample must bein contact.4.2 The degree of color development, as indicated by thecontrast ratio between the CF test specimen and the back-ground is used to calculate the damage factor.4.2.1 Reversing the positions of the CF and CB test unitswill res
11、ult in an invalid test. In a situation where the fixed areaof CB test unit is affected by a strip of CF unit, an attenuationof the released reactant will occur along the length of the testarea. The test must be conducted according to the conventionsspecified under 4.1 or the test conditions are not
12、being met.4.3 Test Under Stationary ConditionsCB and CF units ofidentical areas are placed face to face and subjected tocontrolled pressure without slippage. The degree of colordevelopment on the CF test specimen, as indicated by thecontrast ratio between the test specimen, and the background isused
13、 to calculate the damage factor.5. Significance and Use5.1 The primary purpose of these tests is to obtain informa-tion from a statistical sampling of a lot or shipment of paper1This practice is under the jurisdiction of ASTM Committee F05 on BusinessImaging Products and is the direct responsibility
14、 of Subcommittee F05.06 onCarbonless and Thermal Imaging Products.Current edition approved Dec. 1, 2004. Published December 2004. Originallyapproved in 1978. Last previous edition approved in 2000 as F 598 00.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Custom
15、er Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from the Technical Association of the Pulp and Paper Industry, P.O.Box 105113, Atlanta, GA 30348.4Available from American National Standards
16、Institute, 25 West 43rd Street, 4thFloor, New York, NY 10036.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.that will predict how well the whole lot will resist capsulardamage from normal handling processes, either in manufactur-ing
17、 or in subsequent processing, storage, and use.5.2 Other aspects of significance are covered in 1.2.6. Interferences6.1 If tests are performed as specified, there are no knowninterferences.7. Apparatus7.1 Bursting Strength Tester5Modified ASTM/TAPPIbursting strength tester (see Annex A1).7.2 Smooth
18、Steel Plate,3by3by14 in. (76 by 76 by 6.4mm) thick, for modifying clamp of bursting strength tester.7.3 OpacimeterStandard ASTM/TAPPI (BNL) Opacime-ter or alternative reflectometer (see Annex A2).7.4 Motorized Dynamic Slippage Tester.5,67.5 Stop Watch or Timer.8. Sampling8.1 The sample of the lot of
19、 paper to be tested shall consistof a percentage of test units so selected that the sample isstatistically representative of the average quality of the lot.8.2 Test Under Dynamic ConditionsThe size of the indi-vidual test units shall be: CF sheet, 2 in. wide by 13 in. (51 by330 mm) long, long side i
20、n machine direction; CB sheet, 218in. wide by 13 in. (54 by 330 mm) long, long side in machinedirection.8.3 Test Under Stationary ConditionsThe size of both CFand CB test units shall be 3 by 3 in. (76 by 76 mm).9. Calibration9.1 Bursting Strength TesterFor general information onthe calibration and u
21、se of bursting strength testers, refer to TestMethod D 774 and Annex A1.9.2 Opacimeter/ReflectometerFor general information onthe calibration and use of BNL Opacimeter/Reflectometers (oralternative instruments), refer to TAPPI T 425, ANSI IT 2.16and IT 2.17 and Annex A2.9.3 Dynamic Slippage TesterIn
22、formation on calibrationand use will be furnished by manufacturer or purchaser.10. Conditioning10.1 Condition the test units for at least 12 h at 736 2F (236 1C) and 50 % relative humidity prior to testing. Refer toPractice D 685.11. Procedure11.1 Test Under Dynamic ConditionsThis test should becond
23、ucted in a conditioned cabinet or room with the tempera-ture and relative humidity controlled as specified in Section 10.Each sample is run in triplicate.11.1.1 Pull a fixed length of CB test unit under a fixed areaof CF test unit.11.1.1.1 The characteristics of the dynamic slippage testerare such t
24、hat the CF test unit will be affected by the entirelength of the exposed CB test unit at a rate of 1 ft/s (305 mm/s)with a contact area of 214 in.2(14.51 cm2) under a pressure of4 psi (28 kPa).11.1.2 After 10 min 6 30 s, take reflectance readings on theCF test specimen at three equidistant intervals
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF59820002004STANDARDPRACTICEFORDETERMININGTHERESISTANCEOFCARBONLESSPAPERSTOCAPSULARDAMAGE 测定 无碳纸耐

链接地址:http://www.mydoc123.com/p-536934.html