ASTM F511-2017 Standard Test Method for Quality of Cut (Joint Tightness) of Resilient Floor Tile《弹性地砖切割质量(接头紧密度)的标准试验方法》.pdf
《ASTM F511-2017 Standard Test Method for Quality of Cut (Joint Tightness) of Resilient Floor Tile《弹性地砖切割质量(接头紧密度)的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F511-2017 Standard Test Method for Quality of Cut (Joint Tightness) of Resilient Floor Tile《弹性地砖切割质量(接头紧密度)的标准试验方法》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F511 17Standard Test Method forQuality of Cut (Joint Tightness) of Resilient Floor Tile1This standard is issued under the fixed designation F511; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, the year of last revisio
2、n. A number in parentheses indicates the year of last reapproval. A superscriptepsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers a means of measuring andevaluating the quality of cut (joint tightness) of square orrectangular resilient
3、floor tile. Characteristics that detract froma monolithic (seamless) appearance, such as burred, chipped,nicked, or beveled edges, or bow cut or rounded corners, aremeasured or observed, or both.1.2 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses
4、are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safet
5、y and health practices and determine the applica-bility of regulatory limitations prior to use.1.4 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Sta
6、ndards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:F141 Terminology Relating to Resilient Floor Coverings2.2 ANSI Standard:2ANSI/ASQC Z1.4, (most recent version) Sampling Proce-dures and Tabl
7、es for Inspection by Attributes3. Significance and Use3.1 Installations of resilient floor tile require tight joints ifsatisfactory appearance is to result. The quality of cut ofresilient tile is determined by this test method.4. Apparatus4.1 Shadow Box, consisting of a backlighted poly(methylmethac
8、rylate) (PMMA) plate measuring 28 by 28 by38 in.(710 by 710 by 9.5 mm). One metal strip, 28 in. long by34 in.(19 mm) wide by18 in. (3.2 mm) thick, and one metal strip,2714 in. (692 mm) long by34 in. wide by18 in. thick, arepermanently attached to the PMMA plate to form an included90 6 10-sec angle a
9、t the lower left-hand corner of the PMMAplate. This is suitable for tiles up to 12 by 12 in. (305 by 305mm). For larger tiles, longer metal strips will have to be used,such that the length of each strip is greater than twice thelongest dimension of the tiles to be measured.4.2 Optical Comparator3Pow
10、er illuminated magnifier,equipped to measure to the nearest 0.001 in. (0.02 mm).4.3 Feeler GagesAs an alternative to the optical compara-tor described in 4.2, a set of feeler gages with a range from0.0015 to 0.035 in. (0.038 to 0.89 mm) for measuring to thenearest 0.001 in. (0.02 mm) may be used.4.4
11、 Wire Gages, sized in increments of 0.005 in. (0.13 mm)from 0.005 to 0.050 in. (0.13 to 1.3 mm).5. Sampling5.1 Sample in accordance with ANSI/ASQC Z1.4, mostrecent version.6. Test Specimen and Sample6.1 The specimen (test unit) shall consist of four nominallysquare or rectangular tiles taken from a
12、sample secured inaccordance with ANSI/ASQC Z1.4, most recent version.6.2 The required number of specimens for each test shall beindicated in the individual material specification. If no numberis given, four units (the specimen) shall be taken from thesampled material and one determination made on ea
13、ch.7. Conditioning7.1 Condition the test tiles in an atmosphere maintained at73.4 6 3.6F (23 6 1C) and 50 6 10 % relative humidity fornot less than 2 h prior to testing.1This test method is under the jurisdiction ofASTM Committee F06 on ResilientFloor Coverings and is the direct responsibility of Su
14、bcommittee F06.20 on TestMethods - Products Construction/Materials.Current edition approved May 1, 2017. Published May 2017. Originallyapproved in 1977. Last previous edition approved in 2011 as F511 11. DOI:10.1520/F0511-17.2Available from the American National Standards Institute, 25 W. 43rd St.,
15、4thFloor, New York, NY 10036.3The sole source of supply of the apparatus known to the committee at this timeis Titan Tool Supply Co., Inc., 68 CometAve., Buffalo, N.Y. 14216. If you are awareof alternative suppliers, please provide this information to ASTM Headquarters.Your comments will receive car
16、eful consideration at a meeting of the responsibletechnical committee, which you may attend.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized princip
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF5112017STANDARDTESTMETHODFORQUALITYOFCUTJOINTTIGHTNESSOFRESILIENTFLOORTILE 弹性 地砖 切割 质量 接头 密度 标准

链接地址:http://www.mydoc123.com/p-536809.html