1、Designation:F51104 Designation: F511 11Standard Test Method forQuality of Cut (Joint Tightness) of Resilient Floor Tile1This standard is issued under the fixed designation F511; the number immediately following the designation indicates the year of originaladoption or, in the case of revision, the y
2、ear of last revision. A number in parentheses indicates the year of last reapproval. A superscriptepsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers a means of measuring and evaluating the quality of cut (joint tightness) of square or r
3、ectangularresilient floor tile. Characteristics that detract from a monolithic (seamless) appearance, such as burred, chipped, nicked, or bevelededges, or bow cut or rounded corners, are measured or observed, or both.1.21.2 The values stated in inch-pound units are to be regarded as standard. The va
4、lues given in parentheses are mathematicalconversions to SI units that are provided for information only and are not considered standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to
5、establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:F141 Terminology Relating to Resilient Floor Coverings2.2 ANSI Standard:2ANSI/ASQC Z1.4-93ANSI/ASQC Z1.4, (most recent version) Sampling P
6、rocedures and Tables for Inspection by Attributes3. Significance and Use3.1 Installations of resilient floor tile require tight joints if satisfactory appearance is to result. The quality of cut of resilient tileis determined by this test method.4. Apparatus4.1 Shadow Box, consisting of a backlighte
7、d poly(methyl methacrylate) (PMMA) plate measuring 28 by 28 by38 in. (710 by710 by 9.5 mm). One metal strip, 28 in. long by34 in. (19 mm) wide by18 in. (3.2 mm) thick, and one metal strip, 2714 in. (692mm) long by34 in. wide by18 in. thick, are permanently attached to the PMMA plate to form an inclu
8、ded 90 6 10-sec angleat the lower left-hand corner of the PMMA plate. This is suitable for tiles up to 12 by 12 in. (305 by 305 mm). For larger tiles,longer metal strips will have to be used, such that the length of each strip is greater than twice the longest dimension of the tilesto be measured.4.
9、2 Optical Comparator3Power illuminated magnifier, equipped to measure to the nearest 0.001 in. (0.02 mm).4.3 Feeler GagesAs an alternative to the optical comparator described in 4.2, a set of feeler gages with a range from 0.0015to 0.035 in. (0.038 to 0.89 mm) for measuring to the nearest 0.001 in.
10、(0.02 mm) may be used.4.4 Wire Gages, sized in increments of 0.005 in. (0.13 mm) from 0.005 to 0.050 in. (0.13 to 1.3 mm).5. Sampling5.1Sample in accordance with ANSI/ASQC Z1.4-93.5.1 Sample in accordance with ANSI/ASQC Z1.4, most recent version.1This test method is under the jurisdiction of ASTM Co
11、mmittee F06 on Resilient Floor Coverings, and is the direct responsibility of Subcommittee F06.20 on TestMethodsProducts Construction/Materials.Current edition approved Nov. 1, 2004. Published December 2004. Originally approved in 1977. Last previous edition approved in 1998 as F51198. DOI:10.1520/F
12、0511-04.on Test Methods - Products Construction/Materials.Current edition approved Jan. 15, 2011. Published February 2011. Originally approved in 1977. Last previous edition approved in 2004 as F511 04. DOI:10.1520/F0511-11.2Available from the American National Standards Institute, 25 W. 43rd St., 4
13、th Floor, New York, NY 10036.3The sole source of supply of the apparatus known to the committee at this time is Titan Tool Supply Co., Inc., 68 Comet Ave., Buffalo, N.Y. 14216. If you are awareof alternative suppliers, please provide this information to ASTM Headquarters. Your comments will receive
14、careful consideration at a meeting of the responsible technicalcommittee, which you may attend.1This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically po
15、ssible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700,
16、West Conshohocken, PA 19428-2959, United States.6. Test Specimen and Sample6.1 The specimen (test unit) shall consist of four nominally square or rectangular tiles taken from a sample secured inaccordance with ANSI/ASQC Z1.4-93Z1.4, most recent version.6.2 The required number of specimens for each t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF5112011STANDARDTESTMETHODFORQUALITYOFCUTJOINTTIGHTNESSOFRESILIENTFLOORTILE 弹性 铺地砖 切口 接缝 密封性 质量 标准

链接地址:http://www.mydoc123.com/p-536808.html