1、Designation: F 511 04Standard Test Method forQuality of Cut (Joint Tightness) of Resilient Floor Tile1This standard is issued under the fixed designation F 511; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revis
2、ion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers a means of measuring andevaluating the quality of cut (joint tightness) of square orrectangular resilie
3、nt floor tile. Characteristics that detract froma monolithic (seamless) appearance, such as burred, chipped,nicked, or beveled edges, or bow cut or rounded corners, aremeasured or observed, or both.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its u
4、se. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ANSI Standard:2ANSI/ASQC Z1.4-93 Sampling Procedures and Tables forInspection by Attribute
5、s3. Significance and Use3.1 Installations of resilient floor tile require tight joints ifsatisfactory appearance is to result. The quality of cut ofresilient tile is determined by this test method.4. Apparatus4.1 Shadow Box, consisting of a backlighted poly(methylmethacrylate) (PMMA) plate measuring
6、 28 by 28 by38 in.(710 by 710 by 9.5 mm). One metal strip, 28 in. long by34 in.(19 mm) wide by18 in. (3.2 mm) thick, and one metal strip,2714 in. (692 mm) long by34 in. wide by18 in. thick, arepermanently attached to the PMMA plate to form an included90 6 10-sec angle at the lower left-hand corner o
7、f the PMMAplate. This is suitable for tiles up to 12 by 12 in. (305 by 305mm). For larger tiles, longer metal strips will have to be used,such that the length of each strip is greater than twice thelongest dimension of the tiles to be measured.4.2 Optical Comparator3Power illuminated magnifier,equip
8、ped to measure to the nearest 0.001 in. (0.02 mm).4.3 Feeler GagesAs an alternative to the optical compara-tor described in 4.2, a set of feeler gages with a range from0.0015 to 0.035 in. (0.038 to 0.89 mm) for measuring to thenearest 0.001 in. (0.02 mm) may be used.4.4 Wire Gages, sized in incremen
9、ts of 0.005 in. (0.13 mm)from 0.005 to 0.050 in. (0.13 to 1.3 mm).5. Sampling5.1 Sample in accordance with ANSI/ASQC Z1.4-936. Test Specimen and Sample6.1 The specimen (test unit) shall consist of four nominallysquare or rectangular tiles taken from a sample secured inaccordance with ANSI/ASQC Z1.4-
10、93.6.2 The required number of specimens for each test shall beindicated in the individual material specification. If no numberis given, four units (the specimen) shall be taken from thesampled material and one determination made on each.7. Conditioning7.1 Condition the test tiles in an atmosphere ma
11、intained at73.4 6 3.6F (23 6 1C) and 50 6 5 % relative humidity fornot less than 2 h prior to testing.7.2 Conduct tests in an atmosphere maintained at 73.463.6F (236 1C) and 50 6 5 % relative humidity.8. Procedure8.1 After conditioning, place a tile from the four-tile testunit into the 90 angle form
12、ed by the two metal strips (4.1).Place the other three tiles of the test unit so as to form afour-tile square with tiles in firm contact. Do not force the tilesagainst each other. Normally, place each adjacent tile so thatalternative tiles are at 90 to each other as regards manufac-turing direction
13、(a checkerboard design). If the tile being testedhas arrows on the back and instructions call for all tile to be1This test method is under the jurisdiction ofASTM Committee F06 on ResilientFloor Coverings, and is the direct responsibility of Subcommittee F06.20 on TestMethodsProducts Construction/Ma
14、terials.Current edition approved Nov. 1, 2004. Published December 2004. Originallyapproved in 1977. Last previous edition approved in 1998 as F 511 98.2Available from the American National Standards Institute, 25 W. 43rd St., 4thFloor, New York, NY 10036.3The sole source of supply of the apparatus k
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF5112004STANDARDTESTMETHODFORQUALITYOFCUTJOINTTIGHTNESSOFRESILIENTFLOORTILE 弹性 铺地砖 切口 接缝 密封性 质量 标准

链接地址:http://www.mydoc123.com/p-536807.html