ASTM F1405-1998(2002) Standard Test Method for Determining the Dynamic Thermal Response of Direct Thermal Imaging Products-Atlantek Method《测定直接热成像产品的动态热敏感性的测试方法》.pdf
《ASTM F1405-1998(2002) Standard Test Method for Determining the Dynamic Thermal Response of Direct Thermal Imaging Products-Atlantek Method《测定直接热成像产品的动态热敏感性的测试方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1405-1998(2002) Standard Test Method for Determining the Dynamic Thermal Response of Direct Thermal Imaging Products-Atlantek Method《测定直接热成像产品的动态热敏感性的测试方法》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 1405 98 (Reapproved 2002)Standard Test Method forDetermining the Dynamic Thermal Response of DirectThermal Imaging ProductsAtlantek Method1This standard is issued under the fixed designation F 1405; the number immediately following the designation indicates the year oforiginal adoptio
2、n or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the measurement of thermalresponse of various dire
3、ct thermal imaging papers or otherthermal-coated substrates used for facsimile, labels, medicalrecorders, plotters, and printers.1.2 The Atlantek Thermal Response Tester Model 200described in this test method may be used for specificationacceptance, product development, and research applications.1.3
4、 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specificpreca
5、utionary statements, see Section 8.2. Referenced Documents2.1 ASTM Standards:D 685 Practice for Conditioning Paper and Paper Productsfor Testing2E 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method3F 1623 Terminology Relating to Thermal Imaging Prod-ucts2
6、2.2 ANSI Standards:4PH 2.17 Density MeasurementsGeometric Conditions forReflection DensityPH 2.18 Density MeasurementsSpectral Conditions2.3 Operators Manual:Atlantek Operators Manual for Model 200 Thermal Re-sponse Test System53. Terminology3.1 Symbols:3.1.1 Tcyclethe time between printed lines. Th
7、e larger theTcyclevalue, the more time between printed lines. The result isslower print speeds. Smaller Tcyclevalues correspond to fasterprint speeds. Time between printed lines equals dot “on” timeplus dot “off” time (Tcycle= Ton+ Toff).3.1.2 Tonthe amount of time that the heating elements(dots) on
8、 the printhead are energized. Typically, this value is inmilliseconds. Tonis also called strobe time.4. Summary of Test Method4.1 This test method involves imaging direct thermal prod-uct using an Atlantek Model 200 Thermal Response TestSystem. The system is designed to provide thermal responsemeasu
9、rements using printheads commonly used in facsimileunits, label printers, medical recorders, plotters, and otherprinters. This system is based on a special purpose controllerboard which drives a standard thermal printhead and a pro-grammable stepping drive controller. This system includesprovisions
10、for mounting standard performance printheads. Apersonal computer controls the system with parameter pro-gramming accomplished from menu-driven software designedspecifically for thermal response and performance character-izations.4.2 To determine thermal response, thermal product in rollor sheet form
11、 is fed into the printer. From the Main Menu, thetest system is configured to the Test Mode. Again from theMain Menu, Execute a Test is chosen. A standard existing testfile can then be loaded and the New Test can be given a filename or default standard test conditions can be used. The testthermal pr
12、oduct (media) is identified, printhead voltage set, andthe test executed. Densitometer measurements can then beentered into the test file (manually or automatically). Data inthe test file created can then be used to graphically display thethermal response of the test thermal product.5. Significance
13、and Use5.1 The Atlantek test system allows simulation of directthermal printers in the marketplace. Thus, this system is usefulin matching direct thermal product performance to variousprinter configurations.5.2 This test system is useful for new product development.Direct thermal printer manufacture
14、rs can design print controlalgorithms to match particular thermal imaging products.1This test method is under the jurisdiction of ASTM Committee F05 on BusinessImaging Products and is the direct responsibility of Subcommittee F05.06 onCarbonless and Thermal Imaging Products.Current edition approved
15、Feb. 10, 1998. Published October 1998. Originallypublished as F 1405 92. Last previous edition F 1405 93(1997).2Annual Book of ASTM Standards, Vol 15.09.3Annual Book of ASTM Standards, Vol 14.02.4Available from American National Standards Institute, 11 West 42nd St. 13thFloor, New York, NY 10036.5Av
16、ailable from Atlantek Corp., 10 High St., Wakefield, RI 02879.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Thermal imaging product manufacturers can formulate anddesign products (media) to provide a match with certain printerdesig
17、ns.5.3 Manufacturing process control can make thermal re-sponse comparisons relative to process changes.5.4 Customers for thermal products can use this test methodto compare supplies from various manufacturers.5.5 The test system can be used to evaluate thermal re-sponse of facsimile, label, medical
18、 recorder, plotter, and otherdirect thermal products (media).5.6 Performance differences between printheads and mediacombinations can be measured and presented graphically.6. Interferences6.1 Testing under controlled environmental conditions isrecommended. Wide variations in temperature and relative
19、humidity can effect image density measurements.6.2 Printhead loading and alignment is important to achievereliable and reproducible results.6.3 When testing new and experimental coatings, the print-head must be visually inspected for any residue or buildup andcleaned if required. Residue may prevent
20、 intimate printheadcontact with the thermal imaging surface, resulting in lowerimage density and may cause printhead damage.6.4 Thermal products are sensitive to prolonged exposure tolight and should be protected from exposure prior to testing.7. Apparatus7.1 Atlantek Thermal Response Test System, M
21、odel 200.37.2 IBM PC/AT, or true compatible with the followingconfiguration: 512K RAM minimum, 12 mhz clock, 20 mega-byte hard disk, 1.2 M floppy disk, standard keyboard, mono-chrome or color system, parallel port (two required for plottingoption) and serial port (two required for automatic densitom
22、-eter readings).7.3 Densitometer, Macbeth Model RD-914 (spectral re-sponse: black and white, visual) or equivalent. A serial inter-face is required for entering density measurements automati-cally to the test data file.7.4 Software, Tech*Graph*Pad6or equivalent (optional forplotting graphs).7.5 Plot
23、ter, HP Colorpro with Centronics parallel printer orequivalent to prepare graphs.8. Hazards8.1 Printhead VoltageKeep applied voltage at or belowthat specified for each printhead to avoid printhead damage.Before powering up the system and applying power, thevoltage adjustment knob on the front panel
24、should be turnedfully counter-clockwise. This ensures that applied voltage willbe below the maximum value recommended for the printhead.8.2 The Tcyclevalue must be at least four times the Tonvaluewhen in full-width printing mode or two times the Tonvalue inreduced-width mode. The operating system so
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF140519982002STANDARDTESTMETHODFORDETERMININGTHEDYNAMICTHERMALRESPONSEOFDIRECTTHERMALIMAGINGPRODUCTSATLANTEKMETHOD

链接地址:http://www.mydoc123.com/p-534811.html