1、Designation: F 1255 90 (Reapproved 2002)Standard Practice forPerformance of Prehospital Automated Defibrillation1This standard is issued under the fixed designation F 1255; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year o
2、f last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers guidelines for the performance ofautomated defibrillation.1.2 This practice is one in a set of
3、 performance guidelinesfor prehospital defibrillation.1.3 This practice is specifically not meant to deal withequipment specifications, quality assurance, or training.1.4 This practice is limited to external defibrillators used inthe prehospital setting.1.5 This standard does not purport to address
4、all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:F 1149 Practice for
5、 the Qualifications, Responsibilities, andAuthority of Individuals and Institutions Providing Medi-cal Direction of Emergency Medical Services2F 1177 Terminology Relating to Emergency Medical Ser-vices22.2 American Heart Association Document:National Standards and Guidelines for CardiopulmonaryResus
6、citation (CPR) and Emergency Cardiac Care (ECC),American Heart Association (Current Edition)33. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 automated defibrillatoran automatic or semi-automatic device, or both, capable of rhythm analysis anddefibrillation after electronically
7、 detecting the presence ofventricular fibrillation and ventricular tachycardia.3.1.2 basic life support/cardiopulmonary resuscitation(BLS/CPR)a set of skills that includes airway management,chest compressions, and others defined by the American HeartAssociation.3.1.3 defibrillationthe discharge of a
8、n electrical currentthrough the heart for the purpose of restoring a perfusingcardiac rhythm. For the purpose of this practice, defibrillationmay include cardioversion.3.1.4 operatoras outlined in this practice, a person whohas successfully completed a course of training and may treatprehospital car
9、diac arrest with an automatic or semi-automaticdefibrillator. Legal functioning as an operator will be basedupon licensure or certification requirements, or both, as estab-lished by the authority or authorities having jurisdiction.3.1.5 protocolsSee Terminology F 1177.3.1.6 service medical directort
10、he physician who ismedico-legally responsible for the patient care provided by theoperator (Practice F 1149).3.1.7 standing ordersSee Terminology F 1177.4. Significance and Use4.1 This practice establishes minimum guidelines for pre-hospital automated defibrillation.4.2 This practice does not preclu
11、de the use of automateddefibrillators as prescribed by a licensed physician.4.3 All persons who are identified as prehospital automateddefibrillation operators shall meet the requirements of thispractice.4.4 Using this practice, emergency medical service institu-tions, organizations, and certificati
12、on/licensing agencies shouldbe able to develop standards for the certification/licensing andpractice of the prehospital automated defibrillation operator.5. Guidelines for Prehospital Automated Defibrillation5.1 The operator shall be familiar with all operations of theautomated defibrillator.5.2 The
13、 operator shall be capable of performing prehospitaldefibrillation in accordance with standing orders, protocolsdeveloped, approval by the service medical director or othermedical authority or authorities having jurisdiction, or acombination thereof.5.3 The operator shall be capable of recognizing a
14、 patientwho is unresponsive, apneic and pulseless.5.4 The operator shall be capable of preparing the auto-mated defibrillator for operational use.5.5 The operator shall be capable of applying and activatingthe automated defibrillator according to the manufacturersrecommendations and standing orders/
15、protocols.1This practice is under the jurisdiction of ASTM Committee F30 on EmergencyMedical Services and is the direct responsibility of Subcommittee F30.02 onPersonnel, Training, and Education.Current edition approved March 5, 1990. Published April 1990.2Annual Book of ASTM Standards, Vol 13.02.3A
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF125519902002STANDARDPRACTICEFORPERFORMANCEOFPREHOSPITALAUTOMATEDDEFIBRILLATION 送进 医院 之前 自动 去纤颤 操作

链接地址:http://www.mydoc123.com/p-534497.html