ASTM F1115-1995(2008)e1 Standard Test Method for Determining the Carbon Dioxide Loss of Beverage Containers《测定饮料容器二氧化碳损失的标准试验方法》.pdf
《ASTM F1115-1995(2008)e1 Standard Test Method for Determining the Carbon Dioxide Loss of Beverage Containers《测定饮料容器二氧化碳损失的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F1115-1995(2008)e1 Standard Test Method for Determining the Carbon Dioxide Loss of Beverage Containers《测定饮料容器二氧化碳损失的标准试验方法》.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 1115 95 (Reapproved 2008)e1Standard Test Method forDetermining the Carbon Dioxide Loss of BeverageContainers1This standard is issued under the fixed designation F 1115; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision,
2、 the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.e1NOTEEditorial corrections were made throughout in March 2008.1. Scope1.1 The objective of this test method is to d
3、etermine thecarbon dioxide (CO2) loss from plastic beverage containersafter a specified period of storage time.1.2 Factors contributing to this pressure loss are volumeexpansion and the gas transport characteristics of the packageincluding permeation and leakage.1.3 This standard does not purport to
4、 address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1129 Te
5、rminology Relating to WaterD 1193 Specification for Reagent WaterE 380 Practice for the Use of International System of Units(SI) (the Modernized Metric System)33. Terminology3.1 Units, symbols, and abbreviations used in this testmethod are those recommended by Practice E 380.3.2 Definitions of Terms
6、 Specific to This Standard:3.2.1 carbonation volumethe volume of CO2(at 0C, 1atm pressure) that is dissolved in the carbonated water, dividedby the volume of the liquid (based on water volume at 3.98Cequals 1.000 g/cm3). The conversion of pressure to carbonationvolumes should be made using a carbona
7、tion volumes table. Atable for carbonated water would not necessarily apply toliquids containing additional substances, such as carbonatedbeverages containing sugar.3.2.2 initial pressurethe equilibrium pressure in the testbottles as measured at 24 h after filling with carbonated water.(The filled b
8、ottles are allowed to stand for 24 h to obtaintemperature equilibrium with the test environment and to allowtime for pressure adjustment and equilibration of the CO2inthe headspace and liquid.)3.2.3 samplea set of bottles produced on the same equip-ment in a single run and using the same material an
9、d processconditions. Bottles should represent normal thickness distribu-tion.3.2.4 shelf lifethe number of weeks a sample set of bottlesretain a specified carbonation level, or a percent of the initiallevel.3.2.5 pressure monitoring devicea pressure gage or trans-ducer assembly with support electron
10、ics for indicating internalpressure level of the bottle. This device is used with brassclosure fitting-equipped bottles.3.2.5.1 temperature monitoring devicea thermocouplewith support electronics (same equipment as described in7.2.2). A precision glass thermometer may be used provided abottle filled
11、 with noncarbonated water is used as a control ineach sample set (Procedure A).3.2.6 Terriss CO2Analyzeran electronic unit that willpierce the roll-on closure and automatically read pressure andtemperature and calculate volume of gas (Procedure B).3.2.7 Zahm-Nagle Pressure Testera unit that manually
12、pierces the closure and measures container pressure; an at-tached thermometer is then used to measure temperature(Procedure B).3.2.8 support ringa protrusion below the bottle finishwhich is used to support or stabilize the bottle during fillingand capping.3.2.9 finishthe threaded part of the bottle
13、which receivesthe cap.3.3 For other terms used in this test method, refer toTerminology D 1129.1This test method is under the jurisdiction of ASTM Committee F02 on FlexibleBarrier Packaging and is the direct responsibility of Subcommittee F02.10 onPermeation.Current edition approved Feb. 1, 2008. Pu
14、blished March 2008. Originallyapproved in 1987. Last previous edition approved in 2001 as F 1115 95 (2001).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the stand
15、ards Document Summary page onthe ASTM website.3Withdrawn.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4. Summary of Test Method4.1 Test bottles are filled with carbonated water or beverageand, after closure application, are expose
16、d to test environmentsfor specified time periods. By periodically measuring the initialand final carbonation levels in the container, the carbonationloss and carbonation transfer rate can be calculated.5. Significance and Use5.1 Two procedures, A and B, are outlined in this testmethod. Procedure A i
17、s used most often for development ofvarious beverage container designs to determine the functionalcharacteristics of the package in regard to shelf life. ProcedureB is recommended for use in beverage filling operations as aquality control tool in maintaining the desired CO2fill pres-sure. A loss of
18、CO2will affect product taste.5.1.1 Procedure A involves the use of sensitive pressure andtemperature monitoring equipment where a high degree ofaccuracy is essential, for example, a micro-pressure transducerand thermocouple for measuring pressure and temperature ofthe package in a closed system. Alt
19、ernatively, this proceduremay also use bottles closed with roll-on aluminum capscontaining rubber septums. The septum is pierced with ahypodermic needle attached to a pressure transducer to obtainpressure readings. This procedure should be confined tolaboratories that are practiced in this type of a
20、nalytical testing.5.1.2 Procedure B is more widely used when measuring thecarbonation level of the package due to the simplicity of thetechnique. A simple Zahm-Nagle pressure assembly or TerrisCO2Analyzer is utilized.6. Interferences6.1 The following conditions can interfere with the testresults:6.1
21、.1 CO2leakage at closure due to defective bottle finish orimproper sealing of closure apparatus,6.1.2 CO2leakage due to improper equipment set-up,6.1.3 Change in ambient temperature, upsetting the equilib-rium of the headspace and dissolved CO2gas,6.1.4 Measurement of pressure before the bottle and
22、liquidhave reached ambient temperature,6.1.5 Inaccurate thermocouple device used for measuringthe liquid temperature,6.1.6 Excessive air in the bottle headspace or dissolved inthe liquid,6.1.7 Inaccurate or erratic pressure monitoring device,6.1.8 Ambient humidity in the test area,6.1.9 Age of bottl
23、es, and6.1.10 Excessive bottle-to-bottle variation in the materialdistribution, which may result in a wide variation from bottle tobottle within the sample population.7. Apparatus7.1 Procedures A and B:7.1.1 Bottle Stand, optional.7.1.2 Height Measuring Device, capable of measuring towithin 0.001 in
24、. (optional).7.1.3 Top Loading Balance, capable of weighing to 2500 gwith an accuracy of 60.01 g (optional).7.1.4 Outside Diameter Measuring Device, p tape or similardevice (optional).7.1.5 Carbonated Water or Beverage Dispensing Equip-ment.7.1.6 Micrometer or Ultrasonic Thickness Gage, capable ofme
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF111519952008E1STANDARDTESTMETHODFORDETERMININGTHECARBONDIOXIDELOSSOFBEVERAGECONTAINERS 测定 饮料 容器

链接地址:http://www.mydoc123.com/p-534213.html