ASTM E854-2003 Standard Test Method for Application and Analysis of Solid State Track Recorder (SSTR) Monitors for Reactor Surveillance E706(IIIB)《反应堆监测用固态径迹记录仪(SSTR)监视器的应用和分析的标准试验.pdf
《ASTM E854-2003 Standard Test Method for Application and Analysis of Solid State Track Recorder (SSTR) Monitors for Reactor Surveillance E706(IIIB)《反应堆监测用固态径迹记录仪(SSTR)监视器的应用和分析的标准试验.pdf》由会员分享,可在线阅读,更多相关《ASTM E854-2003 Standard Test Method for Application and Analysis of Solid State Track Recorder (SSTR) Monitors for Reactor Surveillance E706(IIIB)《反应堆监测用固态径迹记录仪(SSTR)监视器的应用和分析的标准试验.pdf(16页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 854 03Standard Test Method forApplication and Analysis of Solid State Track Recorder(SSTR) Monitors for Reactor Surveillance, E706(IIIB)1This standard is issued under the fixed designation E 854; the number immediately following the designation indicates the year oforiginal adoption o
2、r, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method describes the use of solid-state trackrecorders (SSTRs) for
3、neutron dosimetry in light-water reactor(LWR) applications. These applications extend from lowneutron fluence to high neutron fluence, including high powerpressure vessel surveillance and test reactor irradiations as wellas low power benchmark field measurement. (1) This testmethod replaces Method E
4、 418. This test method is moredetailed and special attention is given to the use of state-of-the-art manual and automated track counting methods to attainhigh absolute accuracies. In-situ dosimetry in actual highfluence-high temperature LWR applications is emphasized.1.2 This test method includes SS
5、TR analysis by bothmanual and automated methods. To attain a desired accuracy,the track scanning method selected places limits on theallowable track density. Typically good results are obtained inthe range of 5 to 800 000 tracks/cm2and accurate results athigher track densities have been demonstrated
6、 for some cases.(2) Track density and other factors place limits on the appli-cability of the SSTR method at high fluences. Special caremust be exerted when measuring neutron fluences (E1MeV)above 1016n/cm2. (3)1.3 High fluence limitations exist. These limitations arediscussed in detail in Section 1
7、3 and in references (3-5).1.4 SSTR observations provide time-integrated reactionrates. Therefore, SSTR are truly passive-fluence detectors.They provide permanent records of dosimetry experimentswithout the need for time-dependent corrections, such as decayfactors that arise with radiometric monitors
8、.1.5 Since SSTR provide a spatial record of the time-integrated reaction rate at a microscopic level, they can be usedfor “fine-structure” measurements. For example, spatial distri-butions of isotopic fission rates can be obtained at very highresolution with SSTR.1.6 This standard does not purport t
9、o address the safetyproblems associated with its use. It is the responsibility of theuser of this standard to establish appropriate safety and healthpractices and determine the applicability of regulatory limita-tions prior to use.2. Referenced Documents2.1 ASTM Standards:E 418 Method for Fast-Neutr
10、on Measurements by Track-Etch Techniques2E 844 Guide for Sensor Set Design and Irradiation forReactor Surveillance, E706 (IIC)33. Summary of Test Method3.1 SSTR are usually placed in firm surface contact with afissionable nuclide that has been deposited on a pure nonfis-sionable metal substrate (bac
11、king). This typical SSTR geom-etry is depicted in Fig. 1. Neutron-induced fission produceslatent fission-fragment tracks in the SSTR. These tracks maybe developed by chemical etching to a size that is observablewith an optical microscope. Microphotographs of etched fis-sion tracks in mica, quartz gl
12、ass, and natural quartz crystals canbe seen in Fig. 2.3.1.1 While the conventional SSTR geometry depicted inFig. 1 is not mandatory, it does possess distinct advantages fordosimetry applications. In particular, it provides the highestefficiency and sensitivity while maintaining a fixed and easilyrep
13、roducible geometry.3.1.2 The track density (that is, the number of tracks per unitarea) is proportional to the fission density (that is, the numberof fissions per unit area). The fission density is, in turn,proportional to the exposure fluence experienced by the SSTR.The existence of nonuniformity i
14、n the fission deposit or thepresence of neutron flux gradients can produce non-uniformtrack density. Conversely, with fission deposits of provenuniformity, gradients of the neutron field can be investigatedwith very high spatial resolution.3.2 The total uncertainty of SSTR fission rates is comprised
15、of two independent sources. These two error components arisefrom track counting uncertainties and fission-deposit mass1This test method is under the jurisdiction of ASTM Committee E10 on NuclearTechnology and Applicationsand is the direct responsibility of SubcommitteeE10.05on Nuclear Radiation Metr
16、ology.Current edition approved Feb. 10, 2003. Published March 2003. Originallyapproved in 1981. Last previous edition approved in 1998 as E 854 98.2Discontinued; see 1983 Annual Book of ASTM Standards, Vol 12.02.3Annual Book of ASTM Standards, Vol 12.02.1Copyright ASTM International, 100 Barr Harbor
17、 Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.uncertainties. For work at the highest accuracy levels, fission-deposit mass assay should be performed both before and afterthe SSTR irradiation. In this way, it can be ascertained that nosignificant removal of fission deposit mate
18、rial arose in thecourse of the experiment.4. Significance and Use4.1 The SSTR method provides for the measurement ofabsolute-fission density per unit mass. Absolute-neutron flu-ence can then be inferred from these SSTR-based absolutefission rate observations if an appropriate neutron spectrumaverage
19、 fission cross section is known. This method is highlydiscriminatory against other components of the in-core radia-tion field. Gamma rays, beta rays, and other lightly ionizingparticles do not produce observable tracks in appropriate LWRSSTR candidate materials. However, photofission can contrib-ute
20、 to the observed fission track density and should therefore beaccounted for when nonnegligible. For a more detailed discus-sion of photofission effects, see 13.4.4.2 In this test method, SSTR are placed in surface contactwith fissionable deposits and record neutron-induced fissionfragments. By varia
21、tion of the surface mass density (g/cm2)ofthe fissionable deposit as well as employing the allowablerange of track densities (from roughly 1 event/cm2up to 105events/cm2for manual scanning), a range of total fluencesensitivity covering at least 16 orders of magnitude is possible,from roughly 102n/cm
22、2up to 5 3 1018n/cm2. The allowablerange of fission track densities is broader than the track densityrange for high accuracy manual scanning work with opticalmicroscopy cited in 1.2. In particular, automated and semi-automated methods exist that broaden the customary trackdensity range available wit
23、h manual optical microscopy. In thisbroader track density region, effects of reduced countingstatistics at very low track densities and track pile-up correc-tions at very high track densities can present inherent limita-tions for work of high accuracy. Automated scanning tech-niques are described in
24、 Section 11.4.3 For dosimetry applications, different energy regions ofthe neutron spectrum can be selectively emphasized by chang-ing the nuclide used for the fission deposit.4.4 It is possible to use SSTR directly for neutron dosimetryas described in 4.1 or to obtain a composite neutron detectione
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME8542003STANDARDTESTMETHODFORAPPLICATIONANDANALYSISOFSOLIDSTATETRACKRECORDERSSTRMONITORSFORREACTORSURVEILLANCEE706IIIB

链接地址:http://www.mydoc123.com/p-533666.html