ASTM E720-2008 895 Standard Guide for Selection and Use of Neutron Sensors for Determining Neutron Spectra Employed in Radiation-Hardness Testing of Electronics《电子辐射强度试验中中子波谱测定用中子探.pdf
《ASTM E720-2008 895 Standard Guide for Selection and Use of Neutron Sensors for Determining Neutron Spectra Employed in Radiation-Hardness Testing of Electronics《电子辐射强度试验中中子波谱测定用中子探.pdf》由会员分享,可在线阅读,更多相关《ASTM E720-2008 895 Standard Guide for Selection and Use of Neutron Sensors for Determining Neutron Spectra Employed in Radiation-Hardness Testing of Electronics《电子辐射强度试验中中子波谱测定用中子探.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 720 08Standard Guide forSelection and Use of Neutron Sensors for DeterminingNeutron Spectra Employed in Radiation-Hardness Testing ofElectronics1This standard is issued under the fixed designation E 720; the number immediately following the designation indicates the year oforiginal ad
2、option or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1
3、. Scope1.1 This guide covers the selection and use of neutron-activation detector materials to be employed in neutron spectraadjustment techniques used for radiation-hardness testing ofelectronic semiconductor devices. Sensors are described thathave been used at many radiation hardness-testing facil
4、ities,and comments are offered in table footnotes concerning theappropriateness of each reaction as judged by its cross-sectionaccuracy, ease of use as a sensor, and by past successfulapplication. This guide also discusses the fluence-uniformity,neutron self-shielding, and fluence-depression correct
5、ions thatneed to be considered in choosing the sensor thickness, thesensor covers, and the sensor locations. These considerationsare relevant for the determination of neutron spectra fromassemblies such as TRIGA- and Godiva-type reactors and fromCalifornium irradiators. This guide may also be applic
6、able toother broad energy distribution sources up to 20 MeV.NOTE 1For definitions on terminology used in this guide, see Termi-nology E 170.1.2 This guide also covers the measurement of the gamma-ray or beta-ray emission rates from the activation foils andother sensors as well as the calculation of
7、the absolute specificactivities of these foils. The principal measurement techniqueis high-resolution gamma-ray spectrometry. The activities areused in the determination of the energy-fluence spectrum of theneutron source. See Guide E 721.1.3 Details of measurement and analysis are covered asfollows
8、:1.3.1 Corrections involved in measuring the sensor activi-ties include those for finite sensor size and thickness in thecalibration of the gamma-ray detector, for pulse-height ana-lyzer deadtime and pulse-pileup losses, and for backgroundradioactivity.1.3.2 The primary method for detector calibrati
9、on that usessecondary standard gamma-ray emitting sources is consideredin this guide and in General Methods E 181. In addition, analternative method in which the sensors are activated in theknown spectrum of a benchmark neutron field is discussed inGuide E 1018.1.3.3 A data analysis method is presen
10、ted which accountsfor the following: detector efficiency; background subtraction;irradiation, waiting, and counting times; fission yields andgamma-ray branching ratios; and self-absorption of gammarays and neutrons in the sensors.1.4 The values stated in SI units are to be regarded asstandard. No ot
11、her units of measurement are included in thisstandard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility
12、of regulatory limitations prior to use.2. Referenced Documents2.1 General considerations of neutron-activation detectorsdiscussed in Practice E 261, Test Method E 262, and GuidesE 721 and E 844 are applicable to this guide. Backgroundinformation for applying this guide are given in these and otherre
13、levant standards as follows:2.2 ASTM Standards:2E 170 Terminology Relating to Radiation Measurementsand DosimetryE 181 Test Methods for Detector Calibration and Analysisof RadionuclidesE 261 Practice for Determining Neutron Fluence, FluenceRate, and Spectra by Radioactivation TechniquesE 262 Test Me
14、thod for Determining Thermal Neutron Re-action and Fluence Rates by Radioactivation Techniques1This guide is under the jurisdiction of ASTM Committee E10 on NuclearTechnology and Applications and is the direct responsibility of SubcommitteeE10.07 on Radiation Dosimetry for Radiation Effects on Mater
15、ials and Devices.Current edition approved July 1, 2008. Published July 2008. Originally approvedin 1980. Last previous edition approved in 2004 as E 720 041.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of AS
16、TMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.E 263 Test Method for Measuring Fast-Neutron ReactionRates by Radioactivation of IronE 26
17、4 Test Method for Measuring Fast-Neutron ReactionRates by Radioactivation of NickelE 265 Test Method for Measuring Reaction Rates andFast-Neutron Fluences by Radioactivation of Sulfur-32E 266 Test Method for Measuring Fast-Neutron ReactionRates by Radioactivation of AluminumE 393 Test Method for Mea
18、suring Reaction Rates byAnaly-sis of Barium-140 From Fission DosimetersE 496 Test Method for Measuring Neutron Fluence andAverage Energy from3H(d,n)4He Neutron Generators byRadioactivation TechniquesE 704 Test Method for Measuring Reaction Rates by Ra-dioactivation of Uranium-238E 705 Test Method fo
19、r Measuring Reaction Rates by Ra-dioactivation of Neptunium-237E 721 Guide for Determining Neutron Energy Spectra fromNeutron Sensors for Radiation-Hardness Testing of Elec-tronicsE 844 Guide for Sensor Set Design and Irradiation forReactor Surveillance, E 706(IIC)E 944 Guide for Application of Neut
20、ron Spectrum Adjust-ment Methods in Reactor Surveillance, E 706 (IIA)E 1018 Guide for Application of ASTM Evaluated CrossSection Data File, Matrix E 706 (IIB)E 1297 Test Method for Measuring Fast-Neutron ReactionRates by Radioactivation of Niobium3. Significance and Use3.1 Because of the wide variet
21、y of materials being used inneutron-activation measurements, this guide is presented withthe objective of bringing improved uniformity to the specificfield of interest here: hardness testing of electronics primarilyin critical assembly reactor environments.NOTE 2Some of the techniques discussed are
22、useful for 14-MeVdosimetry. See Test Method E 496 for activation detector materialssuitable for 14-MeV neutron effects testing.NOTE 3The materials recommended in this guide are suitable for252Cf or other weak source effects testing provided the fluence issufficient to generate countable activities.3
23、.2 This guide is organized into two overlapping subjects;the criteria used for sensor selection, and the procedures usedto ensure the proper determination of activities for determina-tion of neutron spectra. See Terminology E 170 and GeneralMethods E 181. Determination of neutron spectra with activa
24、-tion sensor data is discussed in Guides E 721 and E 944.4. Foil Sets4.1 Reactions Considered:4.1.1 Neutron-induced reactions appropriate for this guideare listed in Table 1. The table includes most of the reactionsused in this field. Those not marked with an asterisk arerecommended because of their
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME7202008895STANDARDGUIDEFORSELECTIONANDUSEOFNEUTRONSENSORSFORDETERMININGNEUTRONSPECTRAEMPLOYEDINRADIATIONHARDNESSTESTINGOFELECTRONICS

链接地址:http://www.mydoc123.com/p-533387.html