ASTM E585 E585M-2012 red 8866 Standard Specification for Compacted Mineral-Insulated Metal-Sheathed Base Metal Thermocouple Cable 《压实的矿物绝缘、金属铠装、基底金属热电偶电缆的标准规格》.pdf
《ASTM E585 E585M-2012 red 8866 Standard Specification for Compacted Mineral-Insulated Metal-Sheathed Base Metal Thermocouple Cable 《压实的矿物绝缘、金属铠装、基底金属热电偶电缆的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM E585 E585M-2012 red 8866 Standard Specification for Compacted Mineral-Insulated Metal-Sheathed Base Metal Thermocouple Cable 《压实的矿物绝缘、金属铠装、基底金属热电偶电缆的标准规格》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation:E585/E585M09 Designation: E585/E585M 12Standard Specification forCompacted Mineral-Insulated, Metal-Sheathed, Base MetalThermocouple Cable1This standard is issued under the fixed designation E585/E585M; the number immediately following the designation indicates the yearof original adopti
2、on or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification establishes requirements for compacted, mineral-insulat
3、ed, metal-sheathed, base metal thermocouplecable,2with at least two thermoelements.31.2 This specification describes the required material, processing and testing requirements, and also the optional supplementarytesting and quality assurance and verification choices.1.3 The material of construction
4、includes standard base metal thermoelements, austenitic stainless steel or other corrosionresistant sheath material, and either magnesia (MgO) or alumina (Al2O3) insulation.1.4 The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in ea
5、chsystem may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from thetwo systems may result in non-conformance with the standard1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is
6、 the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 The following documents of the latest issue form a part of this specification to the extent specified
7、herein. In the event ofa conflict between this specification and other specifications referenced herein, this specification shall take precedence.2.2 ASTM Standards:4A213/A213M Specification for Seamless Ferritic and Austenitic Alloy-Steel Boiler, Superheater, and Heat-Exchanger TubesA249/A249M Spec
8、ification for Welded Austenitic Steel Boiler, Superheater, Heat-Exchanger, and Condenser TubesA269 Specification for Seamless and Welded Austenitic Stainless Steel Tubing for General ServiceA632 Specification for Seamless and Welded Austenitic Stainless Steel Tubing (Small-Diameter) for General Serv
9、iceB163 Specification for Seamless Nickel and Nickel Alloy (UNS N06845) Condenser and Heat-Exchanger TubesB167 Specification for Nickel-Chromium-Iron Alloys (UNS N06600, N06601, N06603, N06690, N06693, N06025, N06045,and N06696), Nickel-Chromium-Cobalt-Molybdenum Alloy (UNS N06617), and Nickel-Iron-
10、Chromium-Tungsten Alloy(UNS N06674) Seamless Pipe and TubeB516 Specification for Welded Nickel-Chromium-Iron Alloy (UNS N06600, UNS N06603, UNS N06025, and UNS N06045)TubesE220 Test Method for Calibration of Thermocouples By Comparison TechniquesE230 Specification and Temperature-Electromotive Force
11、 (EMF) Tables for Standardized ThermocouplesE235 Specification for Thermocouples, Sheathed, Type K and Type N, for Nuclear or for Other High-Reliability ApplicationsE344 Terminology Relating to Thermometry and HydrometryE608 Specification for Mineral-Insulated, Metal-Sheathed Base Metal Thermocouple
12、sE780 Test Method for Measuring the Insulation Resistance of Mineral-Insulated, Metal-Sheathed Thermocouples andThermocouple Cable at Room TemperatureE839 Test Methods for Sheathed Thermocouples and Sheathed Thermocouple CableE1652 Specification for Magnesium Oxide and Aluminum Oxide Powder and Crus
13、hable Insulators Used in the Manufacture of1This specification is under the jurisdiction of ASTM Committee E20 on Temperature Measurement and is the direct responsibility of Subcommittee E20.04 onThermocouples.Current edition approved JuneMay 1, 2009.2012. Published September 2009.June 2012. Origina
14、lly approved in 1996. Last previous edition approved in 20042009 asE585/E585M-049. DOI: 10.1520/E0585_E0585M-0912.2The terms “metal sheathed thermocouple cable” or “cable” will be used to describe the subject description.3“Wire” is also used to describe “thermoelements.”4For referenced ASTM standard
15、s, visit the ASTM website, www.astm.org, or contact ASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.1This document is not an ASTM standard and is intended only to provide the user of an AS
16、TM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published
17、 by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Metal-Sheathed Platinum Resistance Thermometers, Base Metal Thermocouples, and Noble Metal Thermocouples2.3 ANSI Standard:ANSI B46.1 Su
18、rface Texture53. Terminology3.1 DefinitionsThe definitions given in Terminology E344 shall apply to this specification.3.2 Definitions of Terms Specific to This Standard:3.2.1 adjacent thermoelement configuration, nthermoelement configuration within a multi-pair cable where two or morepositive therm
19、oelements are immediately adjacent to one another around the circular pattern and two or more negativethermoelements are also immediately adjacent to one another around the circular pattern as shown in Fig. 1 (compare withalternating thermoelement configuration in Fig. 2).3.2.1.1 DiscussionBy defaul
20、t, a multi-pair cable with a thermoelement in the center must be considered an adjacentconfiguration.3.2.2 alternating thermoelement configuration, nthermoelement configuration within a multi-pair cable where positivethermoelements and negative thermoelements alternate around the circular pattern as
21、 shown in Fig. 2 (compare with adjacentthermoelement configuration in Fig. 1).3.2.2.1 DiscussionIn an alternating thermoelement pattern, there are never two or more positive thermoelements nor two ormore negative thermoelements immediately adjacent to one another.3.2.3 lot, na quantity of finished m
22、ineral-insulated, metal-sheathed thermocouple cable manufactured from tubing from thesame heat, wire from the same spool and heat, and insulation from the same batch then assembled and processed together undercontrolled production conditions to the required final outside diameter.3.2.4 raw material,
23、 ntubing, insulation, and wires used in fabrication of the sheathed thermocouple cable.4. Significance and Use4.1 Thermocouple Cable may be Used as Follows:4.1.1 Sheathed thermocouple cable for use in manufacturing thermocouples (see Specification E608).4.1.2 Sheathed thermocouple cable for use as e
24、xtension cable in extremely harsh environments.5. Ordering Information and Basis for Purchase5.1 The purchasing documents shall specify the following options:5.1.1 The total length of finished thermocouple cable and the length of each piece of finished thermocouple cable.5.1.2 The type and quantity
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME585E585M2012RED8866STANDARDSPECIFICATIONFORCOMPACTEDMINERALINSULATEDMETALSHEATHEDBASEMETALTHERMOCOUPLECABLE

链接地址:http://www.mydoc123.com/p-533103.html