ASTM E585 E585M-2004 Standard Specification for Compacted Mineral-Insulated Metal-Sheathed Base Metal Thermocouple Cable.pdf
《ASTM E585 E585M-2004 Standard Specification for Compacted Mineral-Insulated Metal-Sheathed Base Metal Thermocouple Cable.pdf》由会员分享,可在线阅读,更多相关《ASTM E585 E585M-2004 Standard Specification for Compacted Mineral-Insulated Metal-Sheathed Base Metal Thermocouple Cable.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 585/E 585M 04Standard Specification forCompacted Mineral-Insulated, Metal-Sheathed, Base MetalThermocouple Cable1This standard is issued under the fixed designation E 585/E 585M; the number immediately following the designation indicates the yearof original adoption or, in the case of
2、 revision, the year of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification establishes requirements for com-pacted, mineral-insulated, metal-sheathed,
3、 base metal thermo-couple cable,2with at least two thermoelements.31.2 This specification describes the required material, pro-cessing and testing requirements, and also the optional supple-mentary testing and quality assurance and verification choices.1.3 The material of construction includes stand
4、ard basemetal thermoelements, austenitic stainless steel or other corro-sion resistant sheath material, and either magnesia (MgO) oralumina (Al2O3) insulation.1.4 The values stated in inch-pound units or SI (metric)units may be regarded separately as standard. The values statedin each system are not
5、 the exact equivalents, and each systemshall be used independently of the other.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and det
6、ermine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 The following documents of the latest issue form a partof this specification to the extent specified herein. In the eventof a conflict between this specification and other specificationsreferenced herein, thi
7、s specification shall take precedence.2.2 ASTM Standards:4A 213/A 213M Specification for Seamless Ferritic andAustenitic Alloy-Steel Boiler, Superheater, and Heat-Exchanger TubesA 249/A 249M Specification for Welded Austenitic SteelBoiler, Superheater, Heat-Exchanger, and CondenserTubesA 269 Specifi
8、cation for Seamless and Welded AusteniticStainless Steel Tubing for General ServiceA 632 Specification for Seamless and Welded AusteniticStainless Steel Tubing (Small-Diameter) for General Ser-viceB 163 Specification for Seamless Nickel and Nickel AlloyCondenser and Heat-Exchanger TubesB 167 Specifi
9、cation for Nickel-Chromium-Iron Alloys(UNS N06600, N06601, N06603, N06690, N06693,N06025, and N06045) and Nickel-Chromium-Cobalt-Molybdenum Alloy (UNS N06617) Seamless Pipe andTubeB 516 Specification for Welded Nickel-Chromium-Iron Al-loy (UNS N06600, UNS N06603, UNS N06025, and UNSN06045) TubesE 22
10、0 Test Method for Calibration of Thermocouples byComparison TechniquesE 230 Specification and Temperature-Electromotive Force(EMF) Tables for Standardized ThermocouplesE 235 Specification for Thermocouples, Sheathed, Type K,for Nuclear or for Other High-Reliability ApplicationsE 344 Terminology Rela
11、ting to Thermometry and Hydrom-etryE 608/E 608M Specification for Mineral-Insulated, Metal-Sheathed Base-Metal ThermocouplesE 780 Test Method for Measuring the Insulation Resistanceof Sheathed Thermocouple Material at Room TemperatureE 839 Test Methods for Sheathed Thermocouples andSheathed Thermoco
12、uple MaterialE 1652 Specification for Magnesium Oxide and AluminumOxide Powder and Crushable Insulators Used in theManufacture of Metal-Sheathed Platinum Resistance Ther-mometers, Base Metal Thermocouples, and Noble MetalThermocouples2.3 ANSI Standard:1This specification is under the jurisdiction of
13、 ASTM Committee E20 onTemperature Measurement and is the direct responsibility of Subcommittee E20.04on Thermocouples.Current edition approved May 1, 2004. Published May 2004. Originallyapproved in 1996. Last previous edition approved in 2001 as E 585/E 585M-01a.2The terms “metal sheathed thermocoup
14、le cable” or “cable” will be used todescribe the subject description.3“Wire” is also used to describe “thermoelements.”4For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer
15、to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.ANSI B46.1 Surface Texture53. Terminology3.1 DefinitionsThe definitions given in TerminologyE 344 shall apply to this specifica
16、tion.3.2 Definitions of Terms Specific to This Standard:3.2.1 adjacent thermoelement configuration, nthermo-element configuration within a multi-pair cable where two ormore positive thermoelements are immediately adjacent to oneanother around the circular pattern and two or more negativethermoelemen
17、ts are also immediately adjacent to one anotheraround the circular pattern as shown in Fig. 1 (compare withalternating thermoelement configuration in Fig. 2).3.2.1.1 DiscussionBy default, a multi-pair cable with athermoelement in the center must be considered an adjacentconfiguration.3.2.2 alternati
18、ng thermoelement configuration, nthermo-element configuration within a multi-pair cable where positivethermoelements and negative thermoelements alternate aroundthe circular pattern as shown in Fig. 2 (compare with adjacentthermoelement configuration in Fig. 1).3.2.2.1 DiscussionIn an alternating th
19、ermoelement pat-tern, there are never two or more positive thermoelements nortwo or more negative thermoelements immediately adjacent toone another.3.2.3 lot, na quantity of finished mineral-insulated, metal-sheathed thermocouple cable manufactured from tubing fromthe same heat, wire from the same s
20、pool and heat, andinsulation from the same batch then assembled and processedtogether under controlled production conditions to the requiredfinal outside diameter.3.2.4 raw material, ntubing, insulation, and wires used infabrication of the sheathed thermocouple cable.4. Significance and Use4.1 Therm
21、ocouple Cable may be Used as Follows:4.1.1 Sheathed thermocouple cable for use in manufacturingthermocouples (see Specification E 608/E 608M).4.1.2 Sheathed thermocouple cable for use as extensioncable in extremely harsh environments.5. Ordering Information and Basis for Purchase5.1 The purchasing d
22、ocuments shall specify the followingoptions:5.1.1 The total length of finished thermocouple cable andthe length of each piece of finished thermocouple cable.5.1.2 The type and quantity of thermoelements, the thermo-element configuration (see 3.2.1 and 3.2.2), and the toleranceon initial values of em
23、f versus temperature if other thanstandard (see 6.2). Consult individual manufacturers for thenumber of thermoelements limited by cable size.5.1.3 The kind of sheath material (see 7.3) and whether itshall be seamless or welded and drawn. Note that other sheathmaterial may be used with purchaser and
24、producer agreement.5.1.4 The nominal outside diameter of the sheath (see 6.3).5.1.5 The kind of ceramic insulation (see 7.2). Note thatother insulation composition and impurity levels may be usedwith purchaser and producer agreement.5.1.6 The intended operating temperature range of the cable(see 9.8
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME585E585M2004STANDARDSPECIFICATIONFORCOMPACTEDMINERALINSULATEDMETALSHEATHEDBASEMETALTHERMOCOUPLECABLEPDF

链接地址:http://www.mydoc123.com/p-533102.html