ASTM E576-2008 838 Standard Test Method for Frost Dew Point of Sealed Insulating Glass Units in the Vertical Position《密封绝缘玻璃装置垂直位置的霜 露点的标准试验方法》.pdf
《ASTM E576-2008 838 Standard Test Method for Frost Dew Point of Sealed Insulating Glass Units in the Vertical Position《密封绝缘玻璃装置垂直位置的霜 露点的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM E576-2008 838 Standard Test Method for Frost Dew Point of Sealed Insulating Glass Units in the Vertical Position《密封绝缘玻璃装置垂直位置的霜 露点的标准试验方法》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 576 08Standard Test Method forFrost/Dew Point of Sealed Insulating Glass Units in theVertical Position1This standard is issued under the fixed designation E 576; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the ye
2、ar of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method describes a f
3、ield or laboratory proce-dure for determining the frost/dew point within the air space(s)of sealed insulating glass units and establishes the criteria fordetermining whether that point is below or above a given orspecified temperature.1.2 This test method also describes the apparatus to be usedfor t
4、hese determinations.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to
5、 use. For specific hazardstatements, see 9.1.3 and 9.3.7.2. Referenced Documents2.1 ASTM Standards:2C 1036 Specification for Flat GlassE77 Test Method for Inspection and Verification of Ther-mometersE 631 Terminology of Building ConstructionsE 774 Specification for the Classification of the Durabili
6、tyof Sealed Insulating Glass Units33. Terminology3.1 DefinitionsFor definitions of general terms used inthis test method, refer to Terminology E 631.3.2 Definitions of Terms Specific to This Standard:3.2.1 frost statethe case where the frost/dew point of asealed insulating glass unit is above the te
7、st temperaturespecified by the purchaser or user.3.2.2 frost/dew pointthe temperature at which water, or-ganic vapor, or other chemicals begin to appear on the interiorglass surface of a sealed insulating glass unit in contact withthe measuring surface of the frost/dew-point apparatus.3.2.3 no-frost
8、 statethe case where the frost/dew point of asealed insulating glass unit is below the temperature specifiedby the purchaser or user.4. Summary of Test Method4.1 This test method is conducted by the use of a specialapparatus, consisting basically of two chilled cylindrical metalblocks positioned one
9、 over the other and separated by a gap ofcontrollable distance. The upper block has an exposed flatcircular surface, 25 mm (1 in.) in diameter, and can be chilledto far below the ice point by regulating the air gap distancebetween it and the lower metal block which is maintained atapproximately 78C
10、(109F) by dry ice. The test specimenis placed in contact with this chilled flat circular surface of theupper block for specified short periods of time, with the metalsurface at successively lower temperatures, to determine atwhat temperature frost appears on the corresponding lower airspace glass su
11、rface.5. Significance and Use5.1 This test method is suitable for use under actual orsimulated in-service conditions; that is, one side of the unit isexposed to room temperature, while the other side is exposedto natural or simulated weather conditions. Where the glazingconditions and the 24-h histo
12、ry are different or changed fromprevious conditions, the frost/dew point may not be compa-rable to a previous measurement.5.2 This test method is applicable for the uncoated orunfilmed clear (transparent) glass pane of sealed insulatingglass units. If this apparatus is used with coated or filmed gla
13、sspane, the coating or film on the surface of glass pane may bedamaged.1This test method is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.22on Durability Performance of Building Constructions.Current edition approved Apri
14、l 1, 2008. Published May 2008. Originallyapproved in 1976. Last previous edition approved in 1999 as E 576 88 (1999)e1.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer
15、to the standards Document Summary page onthe ASTM website.3Withdrawn.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.3 This test method may require minor modifications tokeep the measuring surface of the frost/dew-point apparatus i
16、ncontact with the glass if the insulating glass unit is not in thetrue vertical position.6. Apparatus6.1 Test Apparatus4(see Fig. 1); consisting of upper andlower cylindrical metal blocks with a thermocouple, bimetallicthermometer, or other suitable temperature sensors beinginserted in the upper blo
17、ck; a control ring; and an insulatedcontainment cylinder fitted with a retainer spring assembly.The two metal blocks are separated by a small air gap, thedistance of which can be regulated by the control ring. Theexposed flat circular surface of the upper block is 25 mm (1 in.)in diameter, has a gro
18、und or lapped finish, and when placed incontact with the glass test specimen, forms the frost/dew pointmeasuring surface. The lower block is chilled by a dry ice packkept in contact with it by the retainer spring assembly,maintaining it at a temperature near to that of sublimating dryice (78C (109F)
19、. Because the solid metal blocks arehighly conductive, the temperature of each is virtually uniform.Use of the control ring adjusts the air gap distance between thetwo blocks to give the desired thermal resistance across the airgap. The circular measuring surface of the upper block is thus4The sole
20、source of supply of the apparatus known to the committee at this timeis Dennis Industries, 20032 Waynegarden Court, Germantown, MD 20874, http:/. If you are aware of alternative suppliers, please provide thisinformation to ASTM International Headquarters. Your comments will receivecareful considerat
21、ion at a meeting of the responsible technical committee,1whichyou may attend.Parts ListPart No. Nomenclature Part No. Nomenclature1 front metal block 12 supporting ring, bottom ofinner tube2 rear metal block 13 control ring3 top cover 14 cover lid, inner tube4 supporting plate, front metalblock15 el
22、bow5 spacer 16 tube, nylon6 spring front metal block 17 main spring7 supporting plate, top ofinner tube18 spacer8 outer tube 19 bearing9 inner tube 20 bimetallic dial thermometer10 disk, dry ice pushing 21 dial indicator11 clamp, dial gage 22 heat source blockFIG. 1 Schematic Diagram of Frost/Dew-Po
23、int ApparatusE576082readily adjusted to the desired temperature while in contactwith the test specimen. The circular measuring surface diam-eter specified is suitable for frost/dew point measurement ofglass up to 6.0 mm (14 in.) thick.6.1.1 Upper and Lower Blocks, aluminum alloy that may beanodized,
24、 conforming to the dimensions shown in Fig. 1. Otherparts of the apparatus may be fabricated from any appropriatematerials.6.1.2 Calibrated Temperature-Measuring Device; such as athermocouple, thermistor, or bimetallic thermometer; having asuitable range graduated in 1C (2F) or smaller units; and an
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME5762008838STANDARDTESTMETHODFORFROSTDEWPOINTOFSEALEDINSULATINGGLASSUNITSINTHEVERTICALPOSITION 密封

链接地址:http://www.mydoc123.com/p-533073.html