ASTM E575-2005(2018) 1250 Standard Practice for Reporting Data from Structural Tests of Building Constructions Elements Connections and Assemblies.pdf
《ASTM E575-2005(2018) 1250 Standard Practice for Reporting Data from Structural Tests of Building Constructions Elements Connections and Assemblies.pdf》由会员分享,可在线阅读,更多相关《ASTM E575-2005(2018) 1250 Standard Practice for Reporting Data from Structural Tests of Building Constructions Elements Connections and Assemblies.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E575 05 (Reapproved 2018)Standard Practice forReporting Data from Structural Tests of BuildingConstructions, Elements, Connections, and Assemblies1This standard is issued under the fixed designation E575; the number immediately following the designation indicates the year oforiginal ado
2、ption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers general use in reporting structuralperformance tes
3、ts of building constructions, elements,connections, and assemblies. A comprehensive report describ-ing the conditions under which the structural data wererecorded will enable other workers to reproduce the testmethods and, as nearly as possible, the results for each materialor assembly, and to recon
4、cile differences that might be found intests by others.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine t
5、he applicability of regulatory limitations prior to use.1.3 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations iss
6、ued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2E631 Terminology of Building Constructions3. Terminology3.1 For definitions of terms used in this practice, seeTerminology E631.4. Significance and Use4.1 This practice provides
7、a standard procedure for report-ing data and results of structural tests used for buildingconstructions, elements, corrections, and assemblies. It enu-merates and discusses the report sections required to reportdata from test methods and practices. The written reports willdescribe the products teste
8、d, method of testing, and results.5. Organization of Report5.1 Generally, a report shall contain the following parts inthe sequence listed:5.1.1 Title page with byline,5.1.2 Object statement,5.1.3 Descriptions of specimen(s) and apparatus,5.1.4 Procedure statement,5.1.5 Discussion of test results,5.
9、1.6 Conclusion,5.1.7 Recommendations,5.1.8 References,5.1.9 Pictures,5.1.10 Tabulations,5.1.11 Calculations, and5.1.12 Supplementary data.5.2 Use the headings listed that are appropriate. Use othermore appropriate headings if they better describe the content.5.3 When the expected readership includes
10、 both experts andlaymen, an early insertion in nontechnical language of thenecessary background, data summary, and results is useful.6. Documented Information6.1 A report shall include the following information, but notnecessarily in the order listed:6.1.1 TitleA title shall be brief but definitive.
11、6.1.2 AuthorOne first name and surname and any profes-sional registration shall be included in a byline for positiveidentification.6.1.3 Date of test and date of report.6.1.4 Test agency, sponsor, and their mailing addresses.6.1.5 Specimen Selection and IdentificationIndicate thenumber of specimens,
12、 method of choosing them, and whetherthey were specially fabricated for this test, prototypes ofplanned production, randomly selected production units, and soforth. If specimens were obtained from routine production,include the manufacturers name, source of supply, specimen1This practice is under th
13、e jurisdiction of ASTM Committee E06 on Perfor-mance of Buildings and is the direct responsibility of Subcommittee E06.11 onHorizontal and Vertical Structures/Structural Performance of Completed Structures.Current edition approved July 1, 2018. Published July 2018. Originally approvedin 1976. Last p
14、revious edition approved in 2011 as E575 05(2011). DOI:10.1520/E0575-05R18.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe
15、 ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelo
16、pment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.1dimensions, model, type, materials, and other pertinent infor-mation such as quality, conditioning, and treatment, includingdata on assembly techniques and
17、 fastenings.6.1.6 Specimen DrawingsDrawings shall provide a de-scription of the physical characteristics and dimensioned sec-tion profiles and any other pertinent construction details. Thisrequirement may be waived if an existing description is easilyavailable and is included by reference. Any modif
18、ication madeto the specimen to obtain a measurement or reading shall benoted. Any unusual characteristics or conditions existing in thespecimen construction prior to test shall be described.6.1.7 Specimen DesignDetails shall be provided for anunderstanding of the principles used in the structural de
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME575200520181250STANDARDPRACTICEFORREPORTINGDATAFROMSTRUCTURALTESTSOFBUILDINGCONSTRUCTIONSELEMENTSCONNECTIONSANDASSEMBLIESPDF

链接地址:http://www.mydoc123.com/p-533071.html