ASTM E574-2006 Standard Specification for Duplex Base Metal Thermocouple Wire With Glass Fiber or Silica Fiber Insulation《用玻璃纤维或硅纤维绝缘的双重基础金属热电偶丝的标准规范》.pdf
《ASTM E574-2006 Standard Specification for Duplex Base Metal Thermocouple Wire With Glass Fiber or Silica Fiber Insulation《用玻璃纤维或硅纤维绝缘的双重基础金属热电偶丝的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM E574-2006 Standard Specification for Duplex Base Metal Thermocouple Wire With Glass Fiber or Silica Fiber Insulation《用玻璃纤维或硅纤维绝缘的双重基础金属热电偶丝的标准规范》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 574 06Standard Specification forDuplex, Base Metal Thermocouple Wire With Glass Fiber orSilica Fiber Insulation1This standard is issued under the fixed designation E 574; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revisio
2、n, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification sets forth the requirements for duplex,types E, J, K, N and T thermocouple wire, in
3、sulated withE-glass, S-glass, amorphous silica fiber or polycrystalline fiber.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address all of thesafety problems, if any, associated with
4、its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1125 Test Methods for Electrical Conductivity and Re-sistivity of W
5、aterE 207 Test Method for Thermal EMF Test of Single Ther-moelement Materials by Comparison with a ReferenceThermoelement of Similar EMF-Temperature PropertiesE 220 Test Method for Calibration of Thermocouples ByComparison TechniquesE 230 Specification and Temperature-Electromotive Force(EMF) Tables
6、 for Standardized ThermocouplesE 344 Terminology Relating to Thermometry and Hydrom-etry3. Terminology3.1 DefinitionsThe definitions given in TerminologyE 344 shall apply to this standard.3.2 Definitions of Terms Specific to This Standard:3.2.1 amorphous silica fiber, ncontinuous filament of heatins
7、ulating material whose principal constituent is amorphoussilica.3.2.2 duplex wire, nmatched pair of parallel, solid ther-moelements, individually insulated (double wrap or braid) withinsulating fibers and a fiber braid of the same material overall.3.2.3 E-glass, nfamily of calcia-alumina-silicate gl
8、assesthat are used for general purposes and most electrical applica-tions.3.2.4 impregnate, vto saturate the fiber insulation of wireswith a high-temperature electrical insulating compound to forma moisture barrier around the wires and to inhibit fraying of thefibers.3.2.5 polycrystalline fiber, nco
9、ntinuous polycrystallinefilament of heat insulating material whose composition isalumina, boria, and silica in an approximate ratio of 3:1:2,respectively.3.2.6 S-glass, nfamily of magnesia-alumina-silicateglasses with a higher tensile strength and higher softeningtemperature than E-glass.4. Signific
10、ance and Use4.1 This specification presents the requirements for impreg-nated and non-impregnated fiber insulated thermocouple wirefor normally accepted industrial use, but does not attempt todefine such usage.4.2 A supplement contains the requirements for insulatedthermocouple wire that will be exp
11、osed to high humidity. Thepurchase order or inquiry shall specify if this supplement isrequired.5. Classification5.1 Class ADuplexE-glass fiber insulated, impregnatedwith a high-temperature electrical insulating compound andcolor coded in accordance with Specification E 230.5.2 Class BDuplexE-glass
12、fiber insulated (Note 1) notimpregnated and not color coded.5.3 Class CDuplexAmorphous silica fiber insulated(Note 2) not impregnated and not color coded.5.4 Class DDuplexPolycrystalline fiber insulated (Notes2 and 3) not impregnated and not color coded.1This specification is under the jurisdiction
13、of ASTM Committee E20 onTemperature Measurement and is the direct responsibility of Subcommittee E20.04on Thermocouples.Current edition approved May 1, 2006. Published May 2006. Originallyapproved in 1976. Last previous edition approved in 2000 as E 574 00.2For referenced ASTM standards, visit the A
14、STM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, Uni
15、ted States.5.5 Class EDuplexS-glass fiber insulated, impregnatedwith a high-temperature electrical insulating compound andcolor coded in accordance with Specification E 230.5.6 Class FDuplexS-glass fiber insulated (Note 1) notimpregnated and not color coded.NOTE 1May be heat treated to retard frayin
16、g when specified inordering information (6.1.8).NOTE 2Fibers may be pre-treated with an organic compound tofacilitate braiding.NOTE 3May be heat cleaned after braiding to remove organiccompound when specified in ordering information (6.1.8).6. Ordering Information6.1 The purchase order shall specify
17、 the following informa-tion:6.1.1 Total insulated wire length,6.1.2 Thermocouple type,6.1.3 Tolerance on initial values of emf versus temperature(standard or special),6.1.4 Class of insulation (see Section 5),6.1.5 Thermoelement diameter (see 7.1.2),6.1.6 Minimum acceptable continuous length per spo
18、ol, ifapplicable,6.1.7 Supplementary testing, if required (see SupplementaryRequirements),6.1.8 Special requirements (if any),6.1.9 Deviations or special requirements not covered herein,and6.1.10 Required documentation (see Section 9).7. Technical Requirements7.1 Insulated Thermocouple Wire:7.1.1 Ma
19、terialsThermoelements shall be solid thermo-couple grade materials with a smooth, bright finish (Note 4)and shall be fully annealed prior to insulating.NOTE 4An optional copper-flash coating on the iron thermoelement ispermitted to prevent rusting. This coating must be applied uniformly soinhomogeni
20、ety is not introduced.7.1.2 SizesThermoelements shall be specified in Ameri-can Wire Gage (AWG) nomenclature. Corresponding thermo-element diameters shall be as listed in Table 1.7.1.3 Calibration:7.1.3.1 Standard MethodWhen required by the purchaseorder, calibration of the insulated thermocouple wi
21、re shall beperformed by one of the procedures described in Test MethodsE 207 or E 220.7.1.3.2 Thermoelement Initial Calibration TolerancesStandard and special tolerances on initial values of emf versustemperature are given in Table 1 of Specification E 230. Thepurchase order shall specify whether st
22、andard or specialtolerances are required.7.2 Insulation Materials:7.2.1 Individual thermoelements shall be covered with abraid, or double wrap (one wrap in each direction) of glassfibers (Classes A and E), a braid of glass fibers (Classes B andF), or braid of fibers (Classes C and D).7.2.2 The outer
23、 covering shall consist of a braid of the samematerial applied over the bare thermoelements.7.2.3 For Classes A and E duplex thermoelements, theinsulation on the individual thermoelements and the outer braidshall be impregnated with a moisture and heat-resistant elec-trical insulating compound. The
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME5742006STANDARDSPECIFICATIONFORDUPLEXBASEMETALTHERMOCOUPLEWIREWITHGLASSFIBERORSILICAFIBERINSULATION

链接地址:http://www.mydoc123.com/p-533067.html