ASTM F205-1994(2005) Standard Test Method for Measuring Diameter of Fine Wire by Weighing《用称量法测定细金属丝直径的测试方法》.pdf
《ASTM F205-1994(2005) Standard Test Method for Measuring Diameter of Fine Wire by Weighing《用称量法测定细金属丝直径的测试方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM F205-1994(2005) Standard Test Method for Measuring Diameter of Fine Wire by Weighing《用称量法测定细金属丝直径的测试方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: F 205 94 (Reapproved 2005)Standard Test Method forMeasuring Diameter of Fine Wire by Weighing1This standard is issued under the fixed designation F 205; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last
2、revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the measurement of the averagediameter of fine wire by weighing a known length; it appliesparticul
3、arly to sizes up to 0.13 mm (0.005 in.) used in electrondevices and lamps.1.2 The values stated in SI units are to be regarded as thestandard. The values given in inch-pound units apply only forthe diameter.1.3 This standard does not purport to address all of thesafety concerns, if any, associated w
4、ith its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2F 180 Test Method for Density of Fine Wire and Ribbon forElectron
5、ic Devices3. Apparatus3.1 The apparatus shall consist of a suitable torsion or otherdirect-reading balance capable of reading to 0.002 mg or 0.1 %of the weight to be weighed (whichever is larger), with anaccuracy of 0.004 mg or 0.2 % (whichever is larger). The rangeof the balance (or the size of the
6、 specimen) shall be such thatthe reading will lie within the upper half of the scale.4. Test Specimens4.1 Test specimens shall be selected at least 1 m from theend of a spool or sufficiently far from the end to be free fromkinks or other damage resulting in lack of straightness of thecut length.4.2
7、The wire shall be drawn from the spool under a loweven tension so that no elongation of the wire takes place.4.3 Each test specimen shall be cut to a length of 200 6 0.1mm. To prevent stretching, care shall be taken so that thetension is just sufficient to eliminate the sag and curl. Anydisagreement
8、 concerning the amount of tension to be used incutting shall be resolved between the manufacturer and thepurchaser.4.4 The test specimen shall be folded upon itself severaltimes and twisted to make a compact bundle with loopconsisting of a single strand for hanging it on the balancebeam. In the case
9、 of multiple specimens, all specimens shall betwisted together and hung by a loop consisting of a singlestrand. The specimen shall be handled as little as possible. Theoperators hands shall be clean and dry.5. Number of Specimens5.1 Weigh a single specimen if its weight lies within theupper half of
10、the scale of the instrument. When the weight isless than half of the scale of the instrument, weigh a sufficientnumber of specimens, 200 mm in length, simultaneously sothat the total weight will register in the upper half of the scale,preferably as close to the limit of the balance as possible. Uset
11、he lowest range instrument compatible with the weight of the200-mm weight specimen to reduce the number of 200-mmlengths that must be weighed together.6. Repetition of Weighing6.1 If the corrected weight of a single specimen lies within60.5 % of either the minimum or the maximum limit specifiedfor t
12、he wire weight, cut and weigh two more specimens of wirein a similar manner. When two or more lengths of wire havebeen weighed simultaneously to produce a reading in the upperhalf of the scale because of the small size of the wire, cut andweigh two more sets of specimens in a similar manner.7. Calib
13、ration and Checking of the Balance7.1 Check the balance regularly in accordance with therecommendations of the manufacturer.7.2 If a variety of weights are to be determined, calibrate thebalance at five major points on the scale and at zero bydetermining the weights of calibrated check weights. If a
14、nypoint is in error by more than 1 %, remove the balance from1This test method is under the jurisdiction of ASTM Committee F01 onElectronics and is the direct responsibility of Subcommittee F01.03 on MetallicMaterials.Current edition approved Jan. 1, 2005. Published January 2005. Originallyapproved
15、in 1945 as B 205 45 T. Last previous edition approved in 1999 as F 205 94(1999).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page
16、onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.service and repair it.Apply corrections determined by checkingto the apparent readings to obtain corrected weights. Obtaincorrections applied to apparent weights by i
17、nterpolation be-tween the closest calibrated points, one above and one belowthe reading.7.3 If the amount of work to be weighed at one point on thescale justifies it, the balance may be calibrated with a standardweight (or combination of weights) deviating by not more than10 % from that of the weigh
18、t to be determined. In this case,adjust the balance so that the balance reads the known weightof the check weight correctly when it is in balance, therebyreducing the correction to zero.7.4 Calibrate the balance, at zero under no load, or atpositive values when loaded to check weights, by using thea
19、verage of three consecutive readings, taken under conditionsspecified in 7.2 or 7.3, whichever is applicable.8. Calibration with Standard Weights8.1 Check weights are subject to change of mass due towear from handling and use, and from chemical action result-ing from exposure. Depending on use, but
20、not less than twicea year, compare the calibrated check weights with the primaryweights, calibrated by the National Institute of Standards andTechnology, and apply the necessary corrections.8.2 The primary standard check weights shall be NISTClass M, or equivalent, for weight determinations of 2.00
21、mgor less, and Class S, or equivalent, for weight determinationsover 2.00 mg.9. Procedure9.1 Handle and use the balance as recommended by themanufacturer. Direct particular attention to requirements forcareful handling, protection from vibration and atmosphericdust, errors induced by temperature cha
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMF20519942005STANDARDTESTMETHODFORMEASURINGDIAMETEROFFINEWIREBYWEIGHING 称量 测定 金属丝 直径 测试 方法 PDF

链接地址:http://www.mydoc123.com/p-532501.html