《ASTM E2339-2015 Standard Practice for Digital Imaging and Communication in Nondestructive Evaluation (DICONDE)《无损评价中数字成像和通信 (DICONDE) 的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E2339-2015 Standard Practice for Digital Imaging and Communication in Nondestructive Evaluation (DICONDE)《无损评价中数字成像和通信 (DICONDE) 的标准实施规程》.pdf(12页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E2339 11E2339 15Standard Practice forDigital Imaging and Communication in NondestructiveEvaluation (DICONDE)1This standard is issued under the fixed designation E2339; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, th
2、e year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope*1.1 This practice facilit
3、ates the interoperability of NDE imaging and data acquisition equipment by specifying the image datain commonly accepted terms. This practice represents a harmonization of NDE imaging systems, or modalities, with the NEMAStandards Publication titled Digital Imaging and Communications in Medicine (DI
4、COM, see http:/medical.nema.org), aninternational standard for image data acquisition, review, storage and archival. In addition, this practice will provide a standard setof industrial NDE specific information object definitions, which travel beyond the scope of standard DICOM modalities. The goalof
5、 this practice is to provide a standard by which NDE image/signal data may be displayed on by any system conforming to theASTM DICONDE format, regardless of which NDE modality was used to acquire the data.1.2 This practice has been developed to overcome the issues that arise when archiving or analyz
6、ing the data from a variety ofNDE techniques, each using proprietary data acquisition systems. As data acquisition modalities evolve, data acquired in the pastmust remain decipherable. This practice proposes an image data file format in such a way that all the technique parameters, alongwith the ima
7、ge file, are preserved, regardless of changes in NDE technology. This practice will also permit the viewing of a varietyof image types (CT, CR, Ultrasonic, Infrared and Eddy Current) on a single workstation, maintaining all of the pertinent techniqueparameters along with the image file. This practic
8、e addresses the exchange of digital information between NDE imagingequipment.1.3 This practice does not specify:1.3.1 A complete description of all the information necessary to implement the DICONDE standard for an imaging modality.This document must be used in conjunction with one of the method-spe
9、cific DICONDE Standard Practice documents to completelydescribe all the requirements necessary to implement the DICONDE standard for an imaging modality. See Section 2.1 of thisdocument for a current list of the method-specific standard practice documents.1.3.2 A testing or validation procedure to a
10、ssess an implementations conformance to the standard.1.3.3 The implementation details of any features of the standard on a device claiming conformance.1.3.4 The overall set of features and functions to be expected from a system implemented by integrating a group of devices eachclaiming DICONDE or DI
11、COM conformance.1.4 Although this practice contains no values that require units, it does describe methods to store and communicate data thatdo require units to be properly interpreted. The SI units required by this practice are to be regarded as standard. No other unitsof measurement are included i
12、n this standard.1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2
13、. Referenced Documents2.1 ASTM Standards:2E1316 Terminology for Nondestructive Examinations1 This practice is under the jurisdiction of ASTM Committee E07 on Nondestructive Testing and is the direct responsibility of Subcommittee E07.11 on Digital Imagingand Communication in Nondestructive Evaluatio
14、n (DICONDE).Current edition approved Dec. 1, 2011Dec. 1, 2015. Published January 2012December 2015. Originally approved in 2004. Last previous edition approved in 20102011as E2339 - 10.E2339 - 11. DOI: 10.1520/E2339-11.10.1520/E2339-15.2 For referencedASTM standards, visit theASTM website, www.astm.
15、org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what chan
16、ges have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the offic
17、ial document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1E2663 Practice for Digital Imaging and Communication in Nondestructive Evaluation (DICONDE) for Ultrasonic T
18、est MethodsE2699 Practice for Digital Imaging and Communication in Nondestructive Evaluation (DICONDE) for Digital Radiographic(DR) Test MethodsE2738 Practice for Digital Imaging and Communication Nondestructive Evaluation (DICONDE) for Computed Radiography(CR) Test MethodsE2767 Practice for Digital
19、 Imaging and Communication in Nondestructive Evaluation (DICONDE) for X-ray ComputedTomography (CT) Test MethodsE2934 Practice for Digital Imaging and Communication in Nondestructive Evaluation (DICONDE) for Eddy Current (EC) TestMethods2.2 Other Documentation:3NEMA Standards Publication PS3.1, Vers
20、ion 3: Digital Imaging and Communications in Medicine (DICOM)ACR-NEMA 3001998 Digital Imaging and Communication in Medicine3. Terminology3.1 Definitions:3.1.1 Nondestructive evaluation terms used in this practice can be found in Terminology E1316.3.2 Definitions of Terms Specific to This Standard:3.
21、2.1 AEapplication entity3.2.2 attributea property of an information object. An attribute has a name and a value, which are independent of anyencoding scheme.3.2.3 attribute tag a unique identifier for an attribute of an information object composed of an ordered pair (gggg,eeee) wheregggg represents
22、the group number and eeee represents the data element.3.2.4 conformance statementa formal statement associated with a specific implementation of the standard, specifying theservice class, information objects, and communications protocols supported by the implementations.3.2.5 data dictionarya regist
23、ry of data elements, which assigns a unique tag, a name, value characteristics, and semantics toeach data element.3.2.6 data elementa unit of information as defined by a single entry in the data dictionary. An encoded IOD attribute that iscomposed of, at a minimum, three fields: a data element tag,
24、a value length, and a value field.3.2.7 data element taga unique identifier for a data element composed of an ordered pair of numbers (a group numberfollowed by an element number).3.2.8 data element type (type)used to specify whether an attribute of an IOD is required and must have a non-zero value
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME23392015STANDARDPRACTICEFORDIGITALIMAGINGANDCOMMUNICATIONINNONDESTRUCTIVEEVALUATIONDICONDE 无损 评价

链接地址:http://www.mydoc123.com/p-530917.html