1、Designation: E2189 101Standard Test Method forTesting Resistance to Fogging in Insulating Glass Units1This standard is issued under the fixed designation E2189; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revis
2、ion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTE6.1.6, 6.1.7, and 6.2.1 were corrected editorially in March 2012.1. Scope1.1 This test method covers procedures for testing theresistan
3、ce to fogging of preassembled permanently sealedinsulating glass units or insulating glass units with capillarytubes intentionally left open.1.2 This test method is applicable only to sealed insulatingglass units that are constructed with glass.1.3 This test method is applicable to both double-glaze
4、d andtriple-glazed insulating glass units; for triple-glazed insulatingglass units where both of the outer lites are glass and the innerlite is either glass or a suspended film.1.4 The unit construction used in this test method containsconstruction details that are essential components of the test.D
5、ifferent types of glass, different glass thicknesses and differ-ent airspace sizes may affect the test results.1.5 This test method is not applicable to sealed insulatingglass units containing a spandrel glass coating due to testinglimitations.1.6 The values stated in SI units are to be regarded ass
6、tandard. No other units of measurement are included in thisstandard.1.7 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the a
7、pplica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C162 Terminology of Glass and Glass ProductsC717 Terminology of Building Seals and SealantsE631 Terminology of Building ConstructionsE2188 Test Method for Insulating Glass Unit PerformanceE2190 Specificat
8、ion for Insulating Glass Unit Performanceand Evaluation3. Terminology3.1 Definition of Terms:3.1.1 For definitions of terms found in the standard, refer toTerminology C717, Terminology C162 and Terminology E631.3.2 Definitions of Terms Specific to This Standard:3.2.1 fog, nvisible deposits present a
9、fter testing in accor-dance with Section 8 that were not present prior to testing. Fogdoes not include defects in a glass coating or the glass substratewhen examined prior to testing.4. Significance and Use4.1 This test method is intended to provide a means fortesting the resistance to fogging in se
10、aled insulating glass units.4.2 This test method is also intended to provide a means fortesting the resistance to fogging caused by components in theinterior of the unit. These interior components include, but arenot limited to, suspended or applied films, decorative compo-nents, muntins, and coatin
11、gs.5. Test Specimens5.1 Each test specimen shall be manufactured in accordancewith Test Method E2188, Section 5.5.2 For test specimens containing muntin bars, the speci-mens shall be fabricated with the muntin bars dividing thespecimens into nine equal areas (3 by 3). See Fig. 1.5.3 Viewing of the f
12、og shall not be compromised by anyinternal component.5.4 For double-glazed units, at least three specimens ofidentical component materials and construction shall be sub-mitted.5.5 For triple-glazed units, at least five specimens of iden-tical component materials and construction shall be submitted.F
13、or these units, the manufacturer shall specify the exteriorsurface.NOTE 1Certain reflective coatings may interfere with the ability toview fog.1This test method is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.22on Durabi
14、lity Performance of Building Constructions.Current edition approved Nov. 1, 2010. Published November 2010. Originallyapproved in 2002. Last previous editions approved in 2002 as E2189 02. DOI:10.1520/E2189-10E01.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Cus
15、tomer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.6 During all stages of storage a
16、nd handling, the units shallbe held in a vertical position with equal support to all panes andno compression loading.5.7 Damaged units shall not be tested.6. Apparatus6.1 Volatile Fog Test Apparatus:6.1.1 The dimensions and components are found in Fig. 2.The construction of the apparatus shall be ca
17、pable of maintain-ing 50 6 3C. In order to maintain this temperature, a fan shallbe mounted in the box. The fan shall run as needed in order tomaintain the air temperature in the apparatus.6.1.2 The apparatus shall be constructed from sturdy, solidmaterials that minimize the escape of ultraviolet li
18、ght into thesurrounding area.12 or34 in. plywood has been found suitablefor this purpose. Stainless steel construction is also acceptable.6.1.3 The interior of the apparatus shall have a reflectivesurface. If plywood is used to construct the apparatus, then linethe entire interior of the apparatus w
19、ith aluminum foil or otherreflective material.6.1.4 The test specimen supports shall be located as shownin Fig. 2.6.1.5 The chamber shall have radiation-shielded thermo-couples to continuously monitor the chamber air temperature atthe locations shown in Fig. 2, identified by the labels TC1through TC
20、4.6.1.6 The cooling plates shall be constructed of a conduc-tive material such as copper or brass. The cooling plates shallbe 150 6 5 mm diameter and shall be placed directly incomplete contact with the glass surface for the duration of thetest. Alternatively, a rectangular cooling plate shall be177
21、 6 6cm2in area with an aspect ratio (long side/short side)less than or equal to 1.4.6.1.7 The cooling water temperature shall be determined asthe water immediately exits the apparatus from each coolingplate as shown in Fig. 2. The cooling water temperature atthese locations shall be 21 6 2C.6.1.8 Al
22、ternatively, an electric chilling apparatus shall beused to control the cooling plate.6.2 Ultraviolet Light Source:6.2.1 WarningUltraviolet light sources used in this testmethod are harmful to the human body, especially to the eyes.Appropriate protective measures must be observed. The sourceshall co
23、nsist of one 300 W ultraviolet lamp3and shall be placedas shown in Fig. 2. The output of the UV source shall bemeasured from a distance of 355 6 5 mm with a long-waveultraviolet meter4and shall not be less than 400 W/cm2.6.3 Fog Examination Light Source:6.3.1 The source shall consist of two fluoresc
24、ent light bulbsin a standard two bulb fixture. These bulbs shall be 20 W, coolwhite bulbs and shall be nominally 610 mm in length.7. Test Specimen Preparation7.1 The sealed insulating glass units shall be sealed aminimum of 4 weeks from date of manufacture to allow forstabilization before testing be
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME21892010E1STANDARDTESTMETHODFORTESTINGRESISTANCETOFOGGINGININSULATINGGLASSUNITS 测定 绝缘 玻璃 器件 耐雾性

链接地址:http://www.mydoc123.com/p-530505.html