1、Designation: E 2030 07An American National StandardStandard Guide forRecommended Uses of Photoluminescent (Phosphorescent)Safety Markings1This standard is issued under the fixed designation E 2030; the number immediately following the designation indicates the year oforiginal adoption or, in the cas
2、e of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This guid
3、e describes recommended uses and informa-tion on installation of photoluminescent safety markings. Thisguide does not establish a standard practice to follow. Requiredmarkings shall be installed in accordance with applicablebuilding codes.1.2 The values stated in SI units are to be regarded as thest
4、andard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the appli
5、ca-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E 284 Terminology of AppearanceE 2072 Specification for Photoluminescent (Phosphores-cent) Safety Markings3. Terminology3.1 Definitions of terms in Terminology E 284 are appli-cable to this guide.4. Significa
6、nce and Use4.1 Photoluminescent safety markings may be used toindicate the direction of the means of egress (escape route).NOTE 1Specification E 2072 covers photometric requirements forphotoluminescent (phosphorescent) safety materials.4.2 Photoluminescent safety markings can be divided intothe foll
7、owing categories:4.2.1 Floor Mounted MarkingsThese markings includefloor tiles, stair treads, stair nosings, floor inserts, tactilewarning strips, coatings, epoxy casting resins, and othermarkings attached to the floor.4.2.2 Wall Mounted MarkingsThese markings includecoatings, wall bases, tapes, cor
8、ner guards, signage, exit maps,guidance strips, and other markings attached to walls, doors,handrails, columns, and other obstructions.5. Recommended Applications5.1 Floor Proximity Exit Path MarkingThis provides acontinuous delineation of the means of egress (escape route)from the occupied area to
9、any exit doors that lead directly tothe public way, except as interrupted by intersecting corridors.Floor proximity exit path markings should be at least 100-mm(4-in.) wide in all locations. If narrower widths are used, theluminance shall increase, as indicated in Specification E 2072,section on Ins
10、tallation Site, On-Site Luminance. Floor prox-imity exit path markings should be applied to the floor surfaceor installed on the wall, close to the floor (see Figs. 1-3).5.2 Continuous Wall and Floor Markings in Corridors5.2.1 Corridors 2-m (2.2-yd) or wider should be marked onboth sides.5.2.2 In de
11、ad end corridors only, the direction of travelshould be indicated by directional indicators pointing in thedirection of the means of egress (escape route). The maximumspacing between the individual directional indicators should be1-m (1.1-yd).5.3 Marking of Exit Doors and Emergency ExitsExitdoors an
12、d emergency exits in the course of the egress pathshould be marked with high and floor proximity exit signs.Such doors should also either be marked all around byhighlighting their entire frames or by leading the pathwaymarking up to the level of the door handle on the side of thedoor where the handl
13、e is located (see Figs. 1-3). To aid inlocating the door release, its knob/latch/bar should be markedby placing photoluminescent material behind it or on it. (seeFigs. 2 and 3).1This guide is under the jurisdiction of ASTM Committee E12 on Color andAppearance and is the direct responsibility of Subc
14、ommittee E12.13 on Photolu-minescent Safety Markings.Current edition approved Jan. 1, 2007. Published February 2007. Originallyapproved in 1999. Last previous edition approved in 2006 as E 2030 - 06a.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Servic
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME20302007STANDARDGUIDEFORRECOMMENDEDUSESOFPHOTOLUMINESCENTPHOSPHORESCENTSAFETYMARKINGS 推荐 使用 荧光 磷光

链接地址:http://www.mydoc123.com/p-530096.html