ASTM E1745-2011 Standard Specification for Plastic Water Vapor Retarders Used in Contact with Soil or Granular Fill under Concrete Slabs《混凝土板下与地面接触的隔汽层或粒状填料的标准规格》.pdf
《ASTM E1745-2011 Standard Specification for Plastic Water Vapor Retarders Used in Contact with Soil or Granular Fill under Concrete Slabs《混凝土板下与地面接触的隔汽层或粒状填料的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1745-2011 Standard Specification for Plastic Water Vapor Retarders Used in Contact with Soil or Granular Fill under Concrete Slabs《混凝土板下与地面接触的隔汽层或粒状填料的标准规格》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E1745 11Standard Specification forPlastic Water Vapor Retarders Used in Contact with Soil orGranular Fill under Concrete Slabs1This standard is issued under the fixed designation E1745; the number immediately following the designation indicates the year oforiginal adoption or, in the ca
2、se of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers flexible, preformed sheetmembrane materials to be used as vapor
3、retarders in contactwith soil or granular fill under concrete slabs.1.1.1 This specification does not cover bituminous vaporretarders. See Specification E1993 for information on bitumi-nous vapor retarders.1.2 The specified tests are conducted on new materials andmaterials that have been conditioned
4、 or exposed to simulatepotential service conditions.1.3 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.2. Referenced Documents2.1 ASTM S
5、tandards:2C168 Terminology Relating to Thermal InsulationD828 Test Method for Tensile Properties of Paper andPaperboard Using Constant-Rate-of-Elongation Appara-tus3D882 Test Method for Tensile Properties of Thin PlasticSheetingD1709 Test Methods for Impact Resistance of Plastic Filmby the Free-Fall
6、ing Dart MethodE96/E96M Test Methods for Water Vapor Transmission ofMaterialsE154 Test Methods for Water Vapor Retarders Used inContact with Earth Under Concrete Slabs, on Walls, or asGround CoverE631 Terminology of Building ConstructionsE1643 Practice for Selection, Design, Installation, and In-spe
7、ction of Water Vapor Retarders Used in Contact withEarth or Granular Fill Under Concrete SlabsE1993 Specification for Bituminous Water Vapor RetardersUsed in Contact with Soil or Granular Fill Under ConcreteSlabsF1249 Test Method for Water Vapor Transmission RateThrough Plastic Film and Sheeting Usi
8、ng a ModulatedInfrared Sensor3. Terminology3.1 DefinitionsFor definitions of terms used in this speci-fication, see Terminologies C168 and E631.3.2 Definitions of Terms Specific to This Standard:3.2.1 perm, nthe time rate of water vapor migrationthrough a material or a construction of one grain per
9、hour,square foot, inch of mercury pressure difference.3.2.1.1 DiscussionIf a specification states that a one permlimit is required, the same flow rate will be obtained from thefollowing relationships:1 perm = 1 grain/h ft2in. Hg (inchpound)= 57.2 10;12kg/(Pasm2) (SI fundamental units)= 57.2 ng/(Pa s
10、 m2) (SI frequently used)= 0.66g/24hm2 mm Hg (SI has been used but is now obso-lete)3.2.2 vapor retarder, n(formerly vapor barrier) a materialor construction that impedes the transmission of water vaporunder specified conditions.3.2.3 water vapor permeability, na property of materialwhich is water v
11、apor permeance through unit thickness. Sincematerials that provide resistance to vapor flow are never usedin unit thickness, the preferred evaluation of both materials andconstructions is the permeance.3.2.4 water-vapor permeance, nthe time rate of watervapor flow through unit area of the known thic
12、kness of a flatmaterial or a construction normal to two specific parallel1This specification is under the jurisdiction of ASTM Committee E06 onPerformance of Buildings and is the direct responsibility of Subcommittee E06.21on Serviceability.Current edition approved Oct. 1, 2011. Published October 20
13、11. Originallyapproved in 1996. Last previous edition approved in 2009 as E1745 09. DOI:10.1520/E1745-11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standar
14、ds Document Summary page onthe ASTM website.3Withdrawn. The last approved version of this historical standard is referencedon www.astm.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.surfaces induced by unit vapor pressure differ
15、ence between thetwo surfaces under specific temperature and humidity condi-tions. See perm.4. Classification4.1 Materials shall be specified to conform to one of thesethree classes: A, B, or C, or specific requirements shall bespecified in one or more of the properties listed in Table 1.5. Specifyin
16、g Information5.1 Specifications for materials shall include the following:5.1.1 This specification number.5.1.2 ClassA, B, or C, or alternatively, specific performancerequirements for each of the properties listed in Table 1.5.1.3 Performance requirements, if any, for special condi-tions (see 7.3).6
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME17452011STANDARDSPECIFICATIONFORPLASTICWATERVAPORRETARDERSUSEDINCONTACTWITHSOILORGRANULARFILLUNDERCONCRETESLABS

链接地址:http://www.mydoc123.com/p-529368.html