ASTM E1627-1994(2004) Standard Practice for Sensory Evaluation of Edible Oils and Fats《食用油和脂肪的感观评定实用规程》.pdf
《ASTM E1627-1994(2004) Standard Practice for Sensory Evaluation of Edible Oils and Fats《食用油和脂肪的感观评定实用规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM E1627-1994(2004) Standard Practice for Sensory Evaluation of Edible Oils and Fats《食用油和脂肪的感观评定实用规程》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: E 1627 94 (Reapproved 2004)Standard Practice forSensory Evaluation of Edible Oils and Fats1This standard is issued under the fixed designation E 1627; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last re
2、vision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the recommended procedures forthe sensory evaluation of edible oils and fats.1.2 This practice covers t
3、echniques for evaluating odor andflavor in fats and oils, for determining overall odor and flavorintensity, and the intensity of individual odors or flavors.1.3 The techniques used in this practice are applicable tooils (liquid at room temperature) and liquified fats (solid atroom temperature).1.4 T
4、he values in SI units are to be regarded as the standard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bili
5、ty of regulatory limitations prior to use. Specific precau-tions are given in Section 7.2. Referenced Documents2.1 ASTM Standards:E 1346 Practice for Bulk Sampling, Handling, and Prepar-ing Edible Vegetable Oils for Sensory Evaluation23. Terminology3.1 A lexicon specific for descriptors of odors and
6、 flavors inoils and fats is included in Appendix X2.4. Summary of Practice4.1 This practice addresses the procedures for screening andtraining of oil panelists; rating and scoring samples; and datacollection, handling, analysis, and interpretation.5. Significance and Use5.1 The application of this p
7、ractice will help ensure consis-tency in procedures used for the sensory evaluation of edibleoils.5.2 This practice is designed for use by oil processors orresearch laboratories for evaluations by a trained, experiencedsensory panel under the supervision of a sensory professionalor for use by qualit
8、y control and quality assurance personnelfor the sensory evaluation of edible oils and fats.6. Apparatus6.1 Glass Vial, 30-mm outside diameter by 57-mm height,wide-mouth threaded top. Use amber glass for odor/flavorevaluations; clear glass for visual examination.6.2 Circulating Waterbath, with autom
9、atic timer, thermo-stat, and rack.6.3 Waterbath Thermometer, with range from 20 to 100Cin 1C divisions, calibrated for 76-mm immersion, 305 mmlong.6.4 Hard plastic threaded caps with liners, or tape (PFTEpipe thread tape), to cover top of vial opening before cappingwith new, nonmetallic screw-type c
10、aps. Tape should com-pletely cover vial opening or multiple strips of tape should beused.7. Precautions7.1 Panelists and sample servers should avoid introducingextraneous odors during testing by use of products, such asscented hand soap, hand creams, perfume, etc., or odorouswriting instruments or i
11、nks. Panelists should avoid exhalinginto sample vials.8. Procedures for Recruitment and Screening Panelists8.1 For basic information on conducting sensory tests, seeMNL263and STP 758.48.2 For normal sensory acuity for basic tastes, see STP 758.48.3 General Odor or Flavor Recognition Relating to Oils
12、Present prospective panelists with a series of samples and a listof applicable oil descriptors specific for the type of oil to betested (see Appendix X1). Appendix X2 contains definitions,reference standards, and examples of each descriptor. Testprospective panelists for general discrimination and t
13、he abilityto describe samples and demonstrate familiarity with terms.8.4 For general interest and availability, see STP 758.41This practice is under the jurisdiction of ASTM Committee E18 on SensoryEvaluation of Materials and Products and is the direct responsibility of Subcom-mittee E18.06 on Food
14、and Beverage Evaluation.Current edition approved Oct. 1, 2004. Published October 2004. Originallyapproved in 1994. Last previous edition approved in 1998 as E 1627 94 (1998).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For
15、Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Manual on Sensory Testing Methods, ASTM MNL26, ASTM International.4Guidelines for Selection and Training of Sensory Panel Members, ASTM STP758, ASTM International, 1981.1Copyright ASTM I
16、nternational, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.9. Procedures for Training Oil Panelists9.1 See STP 7584for information on panel training.9.2 Determine training based upon test objective. Tests mayinclude intensity ranking, attribute recognition, or
17、differencetests, or a combination thereof (see MNL263).9.3 Terminology/Characteristics (See 3.1):9.3.1 Examples of odor, flavors, and tastes predominatelycharacteristic of various oil types are presented in AppendixX2. Attributes are identified as typical of an unprocessed orpartially processed oil
18、(U), freshly processed oil (F), deterio-rated oil (D), or origin unknown (X). The appendix is a generalguideline based on the attributes typically identified for eachoil type; however, other attributes may be noted.9.4 Prepare training samples characteristic of various odorsor flavors and various in
19、tensity levels. Use Appendix X1 andAppendix X2 as guides.9.5 Evaluate a series of concentrations starting with easilydistinguished samples and proceed to more difficult discrimi-nations.9.6 Evaluate panelists consistency on repeated tests asrecommended in STP 758.410. Procedures for Oil Sample Handl
20、ing, Preparation,and Presentation10.1 For information on serving containers, sample size,heating methods, sample temperature, and presentation meth-ods, see Practice E 1346.10.2 Oils should not be held at serving temperature for morethan 60 min to prevent deterioration from oxidation.10.3 If samples
21、 are presented in pairs or other multiples, itis recommended that a method be used to maintain uniformsample temperature of the oils during testing. Aluminumblocks, with recesses to hold vials, heated at a temperature of5C higher than the serving temperature of the oil will keep thesample at the pro
22、per serving temperature for 10 min. Moldedstyrene (styrofoam) blocks, with recesses to hold vials, willhelp minimize temperature loss. Vials should fit into therecesses or cavities in the blocks deep enough so the oil line inthe vial does not extend above the top of the recess. Thediameter of the al
23、uminum block recess should not be more than1 cm wider than the diameter of the vial to allow adequate heattransfer.11. Instructions to Panelists for Odor Evaluations11.1 Evaluate the oils for odor in the order presented fromleft to right.11.2 Pick up the vial containing the oil; hold the vial asclos
24、e to base as possible.11.3 Swirl the covered vial; lift to nose; remove the cover;sniff the headspace above the oil (use short, “bunny” sniffs);replace the cover quickly.11.4 Sniff in the same mannerdistance from nose, numberof times, length of timefor each sample.11.5 Smell back of hand before test
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
5000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTME162719942004STANDARDPRACTICEFORSENSORYEVALUATIONOFEDIBLEOILSANDFATS 食用油 脂肪 评定 实用 规程 PDF

链接地址:http://www.mydoc123.com/p-529080.html